The Evaluation of Osseointegration of Dental Implant Surface with Different Size of TiO2 Nanotube in Rats

被引:13
|
作者
Yi, Young-Ah [1 ]
Park, Young-Bum [1 ]
Choi, Hyunmin [1 ]
Lee, Keun-Woo [1 ]
Kim, Sun-Jai [2 ]
Kim, Kwang-Mahn [3 ]
Oh, Seunghan [4 ]
Shim, June-Sung [1 ]
机构
[1] Yonsei Univ, Oral Sci Res Ctr, Coll Dent, Dept Prosthodont, Seoul 120752, South Korea
[2] Gangnam Severance Dent Hosp, Dept Prosthodont, Seoul 135720, South Korea
[3] Yonsei Univ, Coll Dent, Dept & Res Inst Dent Biomat & Bioengn, Seoul 120752, South Korea
[4] Wonkwang Univ, Sch Dent, Inst Biomat Implant, Dept Dent Biomat, Seoul 570749, South Korea
关键词
TITANIUM IMPLANTS; UNDERLYING MECHANISMS; SHEAR-STRENGTH; REMOVAL TORQUE; TOPOGRAPHY; ROUGHNESS; ADHESION; MAXILLA; INTEGRATION; INTERFACE;
D O I
10.1155/2015/581713
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
With the development of nanotechnology, many researches have shown that nanometer-scaled materials especially TiO2 nanotube have a positive effect on cellular behavior and surface characteristics of implant, which are considered to be crucial factors in osseointegration. However, it has not yet been verified which nanotube size is effective in osseointegration in vivo. The aim of this study was to evaluate the effect of implant surface-treated with different size of TiO2 nanotubes on osseointegration in rat femur. The customized implants (threaded and nonthreaded type), surface-treated with different diameter of TiO2 nanotubes (30 nm, 50 nm, 70 nm, and 100 nm nanotube), were placed on both sides of the femur of 50 male Sprague-Dawley rats (6 weeks old). Rats were sacrificed at 2 and 6 weeks following surgery; then the specimens were collected by perfusion fixation and the osseointegration of implants was evaluated by radiographic and histologic analyses and removal torque value test. The mean of bone area (%) and the mean of removal torque were different in each group, indicating that the difference in TiO2 nanotube size may influence new bone formation and osseointegration in rats.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The role of TiO2 nanotube surface on osseointegration of titanium implants: Biomechanical and histological study in rats
    Alves-Rezende, Maria C. R.
    Capalbo, Leticia C.
    De Oliveira Limirio, Joao P. J.
    Capalbo, Bruna C.
    Limirio, Pedro H. J. O.
    Rosa, Jorge L.
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (07) : 817 - 823
  • [2] Metal TiO2 Nanotube Layers for the Treatment of Dental Implant Infections
    Roguska, Agata
    Belcarz, Anna
    Zalewska, Justyna
    Holdynski, Marcin
    Andrzejczuk, Mariusz
    Pisarek, Marcin
    Ginalska, Grazyna
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (20) : 17089 - 17099
  • [3] Surface Roughness of Dental Implant and Osseointegration
    Geraldo Roberto Martins Matos
    Journal of Maxillofacial and Oral Surgery, 2021, 20 : 1 - 4
  • [4] Surface Roughness of Dental Implant and Osseointegration
    Matos, Geraldo Roberto Martins
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2021, 20 (01): : 1 - 4
  • [5] Ultrasonic evaluation of dental implant osseointegration
    Vayron, Romain
    Soffer, Emmanuel
    Anagnostou, Fani
    Haiat, Guillaume
    JOURNAL OF BIOMECHANICS, 2014, 47 (14) : 3562 - 3568
  • [6] Investigation of the Effectiveness of Dental Implant Osseointegration Characterized by Different Surface Types
    Astashina, Natalia
    Lugovskoy, Alex
    Kossenko, Aleksey
    Lugovskoy, Svetlana
    Rogozhnikov, Gennadi
    Zinigrad, Michael
    METALS, 2017, 7 (06):
  • [7] Impact of Dental Implant Surface Modifications on Osseointegration
    Smeets, Ralf
    Stadlinger, Bernd
    Schwarz, Frank
    Beck-Broichsitter, Benedicta
    Jung, Ole
    Precht, Clarissa
    Kloss, Frank
    Groebe, Alexander
    Heiland, Max
    Ebker, Tobias
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [8] The Research of Dishevelled-2 in Dental Implant Osseointegration of Hyperlipidemic Rats
    Dong, Xiaofei
    Wang, Zhifeng
    Wang, Hui
    Lan, Jing
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 351 - 356
  • [9] Evaluation of the effects of different sand particles that used in dental implant roughened for osseointegration
    Mehmet Emre Yurttutan
    Ahmet Keskin
    BMC Oral Health, 18
  • [10] Evaluation of the effects of different sand particles that used in dental implant roughened for osseointegration
    Yurttutan, Mehmet Emre
    Keskin, Ahmet
    BMC ORAL HEALTH, 2018, 18