The Evaluation of Osseointegration of Dental Implant Surface with Different Size of TiO2 Nanotube in Rats

被引:13
|
作者
Yi, Young-Ah [1 ]
Park, Young-Bum [1 ]
Choi, Hyunmin [1 ]
Lee, Keun-Woo [1 ]
Kim, Sun-Jai [2 ]
Kim, Kwang-Mahn [3 ]
Oh, Seunghan [4 ]
Shim, June-Sung [1 ]
机构
[1] Yonsei Univ, Oral Sci Res Ctr, Coll Dent, Dept Prosthodont, Seoul 120752, South Korea
[2] Gangnam Severance Dent Hosp, Dept Prosthodont, Seoul 135720, South Korea
[3] Yonsei Univ, Coll Dent, Dept & Res Inst Dent Biomat & Bioengn, Seoul 120752, South Korea
[4] Wonkwang Univ, Sch Dent, Inst Biomat Implant, Dept Dent Biomat, Seoul 570749, South Korea
关键词
TITANIUM IMPLANTS; UNDERLYING MECHANISMS; SHEAR-STRENGTH; REMOVAL TORQUE; TOPOGRAPHY; ROUGHNESS; ADHESION; MAXILLA; INTEGRATION; INTERFACE;
D O I
10.1155/2015/581713
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
With the development of nanotechnology, many researches have shown that nanometer-scaled materials especially TiO2 nanotube have a positive effect on cellular behavior and surface characteristics of implant, which are considered to be crucial factors in osseointegration. However, it has not yet been verified which nanotube size is effective in osseointegration in vivo. The aim of this study was to evaluate the effect of implant surface-treated with different size of TiO2 nanotubes on osseointegration in rat femur. The customized implants (threaded and nonthreaded type), surface-treated with different diameter of TiO2 nanotubes (30 nm, 50 nm, 70 nm, and 100 nm nanotube), were placed on both sides of the femur of 50 male Sprague-Dawley rats (6 weeks old). Rats were sacrificed at 2 and 6 weeks following surgery; then the specimens were collected by perfusion fixation and the osseointegration of implants was evaluated by radiographic and histologic analyses and removal torque value test. The mean of bone area (%) and the mean of removal torque were different in each group, indicating that the difference in TiO2 nanotube size may influence new bone formation and osseointegration in rats.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Fabrication and surface characterization of a TiO2 nanotube surface by using electrochemical oxidation
    Chung, Eun Hyuk
    Yu, Seong Mi
    Baek, Seong Rim
    Jang, Eun-Kyung
    Han, Hyun Ju
    Kim, Jong Pil
    Hong, Tae Eun
    Bae, Jong-Seong
    Jin, Jong Sung
    Jeong, Euh Duck
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (06) : 924 - 927
  • [42] Fabrication and surface characterization of a TiO2 nanotube surface by using electrochemical oxidation
    Eun Hyuk Chung
    Seong Mi Yu
    Seong Rim Baek
    Eun-Kyung Jang
    Hyun Ju Han
    Jong Pil Kim
    Tae Eun Hong
    Jong-Seong Bae
    Jong Sung Jin
    Euh Duck Jeong
    Journal of the Korean Physical Society, 2012, 61 : 924 - 927
  • [43] Effects of TiO2 nanotubes with different diameters on gene expression and osseointegration of implants in minipigs
    Wang, Na
    Li, Hongyi
    Lue, Wulong
    Li, Jinghui
    Wang, Jinshu
    Zhang, Zhenting
    Liu, Yiran
    BIOMATERIALS, 2011, 32 (29) : 6900 - 6911
  • [44] Osseointegration of Implants Surface-Treated with Various Diameters of TiO2 Nanotubes in Rabbit
    Kang, Cheul-Goo
    Park, Young-Bum
    Choi, Hyunmin
    Oh, Seunghan
    Lee, Keun-Woo
    Choi, Seong-Ho
    Shim, June-Sung
    JOURNAL OF NANOMATERIALS, 2015, 2015
  • [45] Osseointegration of a New, Ultrahydrophilic and Nanostructured Dental Implant Surface: A Comparative In Vivo Study
    Pabst, Andreas
    Asran, Ashraf
    Lueers, Steffen
    Laub, Markus
    Holfeld, Christopher
    Palarie, Victor
    Thiem, Daniel G. E.
    Becker, Philipp
    Hartmann, Amely
    Heimes, Diana
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    BIOMEDICINES, 2022, 10 (05)
  • [46] Hydroxyapatite Coating on TiO2 Nanotube by Sol-Gel Method for Implant Applications
    Lim, Hyun-Pil
    Park, Sang-Won
    Yun, Kwi-Dug
    Park, Chan
    Ji, Min-Kyung
    Oh, Gye-Jeong
    Lee, Jong-Tak
    Lee, Kwangmin
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2018, 18 (02) : 1403 - 1405
  • [47] Evaluation of Effects of Topical Melatonin Application on Osseointegration of Dental Implant: An Experimental Study
    Dundar, Serkan
    Yaman, Ferhan
    Saybak, Arif
    Ozupek, M. Fatih
    Toy, Vesile Elif
    Gul, Mehmet
    Ozercan, I. Hanifi
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 386 - 389
  • [48] TiO2 nanotube arrays fabricated by anodization in different electrolytes for biosensing
    Xiao, Peng
    Garcia, Betzaida Batalla
    Guo, Qing
    Liu, Dawei
    Cao, Guozhong
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (09) : 2441 - 2447
  • [49] Surface wettability of TiO2 nanotube arrays prepared by electrochemical anodization
    Liu, Guohua
    Du, Kang
    Wang, Kaiying
    APPLIED SURFACE SCIENCE, 2016, 388 : 313 - 320
  • [50] The reaction mechanism of photoelectrocatalysis on the surface of TiO2 nanotube array electrode
    Li, Linzhi
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2020, 15 (S1)