Ultrasonic evaluation of dental implant osseointegration

被引:39
|
作者
Vayron, Romain [1 ]
Soffer, Emmanuel [2 ]
Anagnostou, Fani [2 ]
Haiat, Guillaume [1 ]
机构
[1] CNRS, Lab Modelisat & Simulat MultiEchelle, MSME UMR 8208, F-94010 Creteil, France
[2] Univ Paris 07, CNRS, Lab Biomecan Biomat Osteo Articulaires, UMR 7052, Paris, France
关键词
Dental implant; Animal model; Osseointegration; Quantitative ultrasound; RESONANCE FREQUENCY-ANALYSIS; IMMEDIATELY LOADED IMPLANTS; BIOMECHANICAL PROPERTIES; NUMERICAL-SIMULATION; TITANIUM IMPLANTS; BONE RESPONSE; STABILITY; CEMENT; SURFACES; JAWBONE;
D O I
10.1016/j.jbiomech.2014.07.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Dental implants are widely used for oral rehabilitation. However, there remain risks of failure which are difficult to anticipate and depend on the implant osseointegration. The objective of this in vivo study is to determine the variation of the echographic ultrasonic response of a dental implant to bone healing around the implant interface. Twenty one dental implants were inserted in the femur of seven New Zealand white rabbits. Two animals were sacrificed after a healing duration of two weeks, three animals after six weeks and six animals after eleven weeks. The 10 MHz ultrasonic response of the implant was measured just after the implantation using a dedicated device positioned at the emerging surface of each dental implant. The measurements were realized again before the sacrifice with the same device. An indicator (I) over tilde was derived based on the amplitude of the rf signal obtained for each configuration. The bone-Implant Contact (BIC) ratio was determined by histological analyses. The average value of the relative variation of the indicator (I) over tilde obtained after initial surgery and after the corresponding healing period varies between 7% and 40%. A Kruskal Wallis test (p < 0.01) revealed a significant decrease of the value of the indicator <(I)over tilde> as function of healing time. The indicator (I) over tilde was significantly correlated (R-2=0.45) with the BIC ratio. The results show that the ultrasonic response of a dental implant varies significantly as a function of healing time, which paves the way for the development of a new quantitative ultrasound (QUS) method in oral implantology. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3562 / 3568
页数:7
相关论文
共 50 条
  • [1] Evaluation of dental implant osseointegration using Ultrasonic Spectrometry: A phantom study
    1600, World Scientific and Engineering Academy and Society, Ag. Ioannou Theologou 17-23, Zographou, Athens, 15773, Greece (10):
  • [2] Functional Assessment of Dental Implant Osseointegration
    Chang, Po-Chun
    Giannobile, William V.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2012, 32 (05) : 541 - 541
  • [3] Osseointegration of a novel dental implant in canine
    Wang, Lingxiao
    Gao, Zhenhua
    Su, Yucheng
    Liu, Qian
    Ge, Yi
    Shan, Zhaochen
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Osseointegration of a novel dental implant in canine
    Lingxiao Wang
    Zhenhua Gao
    Yucheng Su
    Qian Liu
    Yi Ge
    Zhaochen Shan
    Scientific Reports, 11
  • [5] Surface Roughness of Dental Implant and Osseointegration
    Geraldo Roberto Martins Matos
    Journal of Maxillofacial and Oral Surgery, 2021, 20 : 1 - 4
  • [6] Electronic monitoring of dental implant osseointegration
    Dario, LJ
    Cucchiaro, PJ
    Deluzio, AJ
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (04): : 483 - 490
  • [7] Dynamic Characterization of Dental Implant Osseointegration
    Hsieh, Bin-Xun
    Cong, Trinh Minh
    Chen, Chin-Sung
    Pan, Min-Chun
    2016 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING (BME-HUST), 2016, : 139 - 145
  • [8] Surface Roughness of Dental Implant and Osseointegration
    Matos, Geraldo Roberto Martins
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2021, 20 (01): : 1 - 4
  • [9] EVALUATION OF THE EFFECTS OF DIAGNOSTIC RADIATION ON TITANIUM DENTAL IMPLANT OSSEOINTEGRATION IN THE MICROPIG
    BASQUILL, PJ
    STEFLIK, DE
    BRENNAN, WA
    HORNER, J
    VANDYKE, TE
    JOURNAL OF PERIODONTOLOGY, 1994, 65 (09) : 872 - 880
  • [10] Evaluation of Effects of Topical Melatonin Application on Osseointegration of Dental Implant: An Experimental Study
    Dundar, Serkan
    Yaman, Ferhan
    Saybak, Arif
    Ozupek, M. Fatih
    Toy, Vesile Elif
    Gul, Mehmet
    Ozercan, I. Hanifi
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 386 - 389