Ultrasonic evaluation of dental implant osseointegration

被引:39
|
作者
Vayron, Romain [1 ]
Soffer, Emmanuel [2 ]
Anagnostou, Fani [2 ]
Haiat, Guillaume [1 ]
机构
[1] CNRS, Lab Modelisat & Simulat MultiEchelle, MSME UMR 8208, F-94010 Creteil, France
[2] Univ Paris 07, CNRS, Lab Biomecan Biomat Osteo Articulaires, UMR 7052, Paris, France
关键词
Dental implant; Animal model; Osseointegration; Quantitative ultrasound; RESONANCE FREQUENCY-ANALYSIS; IMMEDIATELY LOADED IMPLANTS; BIOMECHANICAL PROPERTIES; NUMERICAL-SIMULATION; TITANIUM IMPLANTS; BONE RESPONSE; STABILITY; CEMENT; SURFACES; JAWBONE;
D O I
10.1016/j.jbiomech.2014.07.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Dental implants are widely used for oral rehabilitation. However, there remain risks of failure which are difficult to anticipate and depend on the implant osseointegration. The objective of this in vivo study is to determine the variation of the echographic ultrasonic response of a dental implant to bone healing around the implant interface. Twenty one dental implants were inserted in the femur of seven New Zealand white rabbits. Two animals were sacrificed after a healing duration of two weeks, three animals after six weeks and six animals after eleven weeks. The 10 MHz ultrasonic response of the implant was measured just after the implantation using a dedicated device positioned at the emerging surface of each dental implant. The measurements were realized again before the sacrifice with the same device. An indicator (I) over tilde was derived based on the amplitude of the rf signal obtained for each configuration. The bone-Implant Contact (BIC) ratio was determined by histological analyses. The average value of the relative variation of the indicator (I) over tilde obtained after initial surgery and after the corresponding healing period varies between 7% and 40%. A Kruskal Wallis test (p < 0.01) revealed a significant decrease of the value of the indicator <(I)over tilde> as function of healing time. The indicator (I) over tilde was significantly correlated (R-2=0.45) with the BIC ratio. The results show that the ultrasonic response of a dental implant varies significantly as a function of healing time, which paves the way for the development of a new quantitative ultrasound (QUS) method in oral implantology. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3562 / 3568
页数:7
相关论文
共 50 条
  • [31] INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT
    Kim, Se-Ho
    Kim, Soung-Min
    Kim, Ji-Hyuck
    Park, Young-Wook
    Park, Chan-Jin
    Jung, Ki-Myoung
    Lee, Suk-Keun
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2005, 31 (04) : 291 - 299
  • [32] Osteopontin on the Dental Implant Surface Promotes Direct Osteogenesis in Osseointegration
    Makishi, Sanako
    Yamazaki, Tomohiko
    Ohshima, Hayato
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (03)
  • [33] The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation
    Kligman, Stefanie
    Ren, Zhi
    Chung, Chun-Hsi
    Perillo, Michael Angelo
    Chang, Yu-Cheng
    Koo, Hyun
    Zheng, Zhong
    Li, Chenshuang
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (08)
  • [34] Dental implant bioactive surface modifications and their effects on osseointegration: A review
    Meng H.-W.
    Chien E.Y.
    Chien H.-H.
    Biomarker Research, 4 (1)
  • [35] Clinical efficacy of photobiomodulation on dental implant osseointegration: A systematic review
    Zayed, Sara Mahmoud
    Hakim, Ahmed Adel Abdel
    SAUDI JOURNAL OF MEDICINE & MEDICAL SCIENCES, 2020, 8 (02) : 80 - 86
  • [36] Influence of Dental Implant Surface Modifications on Osseointegration and Biofilm Attachment
    Han, Wen
    Fang, Shuobo
    Zhong, Qun
    Qi, Shengcai
    COATINGS, 2022, 12 (11)
  • [37] Effect of Temperature on the Dental Implant Osseointegration Development in Low-Density Bone: An In Vivo Histological Evaluation
    Trisi, Paolo
    Berardini, Marco
    Falco, Antonello
    Vulpiani, Michele Podaliri
    IMPLANT DENTISTRY, 2015, 24 (01) : 96 - 100
  • [38] Evaluation of the first maxillary molar post-extraction socket as a model for dental implant osseointegration research
    Du, Zhibin
    Lee, Ryan S. B.
    Hamlet, Stephen
    Doan, Nghiem
    Ivanovski, Saso
    Xiao, Yin
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (12) : 1469 - 1478
  • [39] Ultrasonic characterization and multiscale analysis for the evaluation of dental implant stability: A sensitivity study
    Scala, I.
    Rosi, G.
    Nguyen, V. -H.
    Vayron, R.
    Haiat, G.
    Seuret, S.
    Jaffard, S.
    Naili, S.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 42 : 37 - 44
  • [40] Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability
    Mathieu, Vincent
    Anagnostou, Fani
    Soffer, Emmanuel
    Haiat, Guillaume
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (06): : 4062 - 4072