A Software Tool for the Computation of Arterial Pulse Wave Velocity from Flow-sensitive 4D MRI Data

被引:0
|
作者
Drexl, J. [1 ]
Mirzaee, H. [1 ]
Harloff, A. [2 ]
Huellebrand, M. [1 ]
Hennemuth, A. [1 ]
Hahn, H. [1 ]
机构
[1] Fraunhofer MEVIS, Bremen, Germany
[2] Univ Freiburg, Univ Hosp, Dept Neurol, Freiburg, Germany
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Recently, Markl at al. [1] demonstrated that the aortic pulse wave velocity (PWV) can be measured non-invasively based on flow-sensitive 4D MRI. However, the suggested post-processing workflow is very time consuming. in this paper, we present a more efficient PWV computation integrated into a dedicated software assistant, supporting all major steps for PWV computation. The implementation was validated on a digital phantom. Furthermore, two independent observers re-processed the volunteer data from the Markl et al. study with our software, so that outcomes as well as processing times could be compared. The implementation of our method gives similar accuracy and reproducibility to the method of Markl at al, but at a significantly reduced processing time.
引用
收藏
页码:559 / 562
页数:4
相关论文
共 50 条
  • [21] 3D Blood Flow Characteristics in the Carotid Artery Bifurcation Assessed by Flow-Sensitive 4D MRI at 3T
    Harloff, A.
    Albrecht, F.
    Spreer, J.
    Stalder, A. F.
    Bock, J.
    Frydrychowicz, A.
    Schoellhorn, J.
    Hetzel, A.
    Schumacher, M.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 65 - 74
  • [22] Quantification of aortic pulse wave velocity in preterm infants using 4D phase contrast MRI
    Kathryn Broadhouse
    Anthony N Price
    Giuliana Durighel
    Anna Finnemore
    David J Cox
    AD Edwards
    Joseph V Hajnal
    Alan Groves
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [23] Changes in segmental pulse wave velocity of the thoracic aorta with age and left ventricular remodelling. An MRI 4D flow study
    Soulat, Gilles
    Gencer, Umit
    Kachenoura, Nadjia
    Villemain, Olivier
    Messas, Emmanuel
    Boutouyrie, Pierre
    Laurent, Stephane
    Mousseaux, Elie
    JOURNAL OF HYPERTENSION, 2020, 38 (01) : 118 - 126
  • [24] Evaluation of Pulse Wave Velocity using 4D CT Cardiogram
    Hu, Weichih
    Tsao, Hsuan-Ming
    Shyu, Liang-Yu
    2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39, 2012, 39 : 577 - 580
  • [25] Analysis of pulse wave velocity in the thoracic aorta by flow-sensitive four-dimensional MRI: Reproducibility and correlation with characteristics in patients with aortic atherosclerosis
    Markl, Michael
    Wallis, Wolf
    Strecker, Christoph
    Gladstone, Beryl Primrose
    Vach, Werner
    Harloff, Andreas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (05) : 1162 - 1168
  • [26] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Sophia Houriez--Gombaud-Saintonge
    Elie Mousseaux
    Ioannis Bargiotas
    Alain De Cesare
    Thomas Dietenbeck
    Kevin Bouaou
    Alban Redheuil
    Gilles Soulat
    Alain Giron
    Umit Gencer
    Damian Craiem
    Emmanuel Messas
    Emilie Bollache
    Yasmina Chenoune
    Nadjia Kachenoura
    Journal of Cardiovascular Magnetic Resonance, 21
  • [27] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Giron, Alain
    Gencer, Umit
    Craiem, Damian
    Messas, Emmanuel
    Bollache, Emilie
    Chenoune, Yasmina
    Kachenoura, Nadjia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
  • [28] Flow-sensitive 4D MRI of the thoracic aorta: Comparison of image quality, quantitative flow, and wall parameters at 1.5 T and 3 T
    Strecker, Christoph
    Harloff, Andreas
    Wallis, Wolf
    Markl, Michael
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1097 - 1103
  • [29] Modeling Bias Error in 4D Flow MRI Velocity Measurements
    Rothenberger, Sean M.
    Zhang, Jiacheng
    Brindise, Melissa C.
    Schnell, Susanne
    Markl, Michael
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (07) : 1802 - 1812
  • [30] A 4D chirp and Fourier velocity encoding method for MRI flow velocity measurement
    Lee, R
    Bottomley, PA
    RADIOLOGY, 1997, 205 : 886 - 886