Radiation detector developments in medical applications: Inorganic scintillators in positron emission tomography

被引:46
|
作者
van Eijk, Carel W. E. [1 ]
机构
[1] Delft Univ Technol, Fac Sci Appl, NL-2629 JB Delft, Netherlands
关键词
D O I
10.1093/rpd/ncn043
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, a number of new gamma-ray scintillators are commercially available. These scintillators are either derived from known scintillators, e. g. Lu(1-x)Y(x)AlO(3): Ce (LuYAP) from LuAlO(3): Ce and Lu(2(1-x))Y(2x)SiO(5): Ce (LYSO) from Lu(2)SiO(5): Ce or are the result of new discoveries, e. g. LaCl(3): Ce and LaBr(3): Ce. The first two materials are primarily of interest because of the relatively high detection efficiency and fast response; LYSO has found application in time-of-light (TOF) positron-emission tomography ( TOF PET) and the LuYAP-LYSO combination is used in small-animal PET. The halide scintillators have an excellent energy resolution of similar to 3% at 662 keV and they have a relatively high light yield. LaBr3: Ce is being studied for application in TOF PET. At the same time, the search for and research on new scintillator materials are going on. For example, LuI(3): Ce is a new material with a very high light yield (similar to 90 000 photons MeV(-1)). Other examples of new materials are (C(6)H(13)NH(3))(2)PbI(4) and (C(3)H(7)NH(3))(2)PbBr(4), organic-inorganic hybrid compounds, of which the former has a very fast sub-nanosecond response. The new scintillators show great promise for new developments in medical applications, in particular, for PET systems.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [41] Positron emission tomography for radiation treatment planning
    Grosu, AL
    Piert, M
    Weber, WA
    Jeremic, B
    Picchio, M
    Schratzenstaller, U
    Zimmermann, FB
    Schwaiger, M
    Molls, M
    STRAHLENTHERAPIE UND ONKOLOGIE, 2005, 181 (08) : 483 - 499
  • [42] Characterisation of a β detector on positron emitters for medical applications
    Collamati, F.
    Moretti, R.
    Alunni-Solestizi, L.
    Bocci, V
    Cartoni, A.
    Collarino, A.
    De Simoni, M.
    Faccini, R.
    Fischetti, M.
    Giordano, A.
    Maccora, D.
    Mancini-Terracciano, C.
    Mirabelli, R.
    Scotognella, T.
    Solfaroli-Camillocci, E.
    Traini, G.
    Morganti, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 67 : 85 - 90
  • [43] BAF2 SCINTILLATORS WITH WIRE CHAMBER READOUT FOR POSITRON EMISSION TOMOGRAPHY
    BRUYNDONCKX, P
    DEBRUYNE, J
    ETIENNE, L
    GRUWE, M
    GUERARD, B
    TAVERNIER, S
    SHUPING, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 107 - 115
  • [44] Energy estimation methods for positron emission tomography detectors composed of multiple scintillators
    Shim, Hyeong Seok
    Cho, Min Jeong
    Lee, Jae Sung
    BIOMEDICAL ENGINEERING LETTERS, 2025, : 489 - 496
  • [45] Positron emission tomography: A practical review of positron emission tomography, clinical applications, and self-examination
    Vidal, JA
    Irani, N
    Redick, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 125 - 125
  • [46] Preface - Neurologic applications of positron emission tomography
    Meltzer, CC
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2003, 13 (04) : XIII - XIII
  • [47] Current clinical applications of positron emission tomography
    Kumar, Aravind Ravi
    AUSTRALIAN PRESCRIBER, 2008, 31 (05) : 123 - 128
  • [48] THE APPLICATIONS IN NEUROSURGERY OF POSITRON EMISSION TOMOGRAPHY (PET)
    LENZI, GL
    FRACKOWIAK, RSJ
    ACTA NEUROCHIRURGICA, 1982, 64 (3-4) : 273 - 274
  • [49] POSITRON EMISSION TOMOGRAPHY SCANNING - APPLICATIONS IN NEWBORNS
    CHUGANI, HT
    CLINICS IN PERINATOLOGY, 1993, 20 (02) : 395 - 409
  • [50] POSITRON EMISSION TOMOGRAPHY - PRINCIPLES AND APPLICATIONS IN CARDIOLOGY
    PORENTA, G
    CZERNIN, J
    SCHELBERT, H
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1992, 142 (15-16) : 358 - &