In recent years, a number of new gamma-ray scintillators are commercially available. These scintillators are either derived from known scintillators, e. g. Lu(1-x)Y(x)AlO(3): Ce (LuYAP) from LuAlO(3): Ce and Lu(2(1-x))Y(2x)SiO(5): Ce (LYSO) from Lu(2)SiO(5): Ce or are the result of new discoveries, e. g. LaCl(3): Ce and LaBr(3): Ce. The first two materials are primarily of interest because of the relatively high detection efficiency and fast response; LYSO has found application in time-of-light (TOF) positron-emission tomography ( TOF PET) and the LuYAP-LYSO combination is used in small-animal PET. The halide scintillators have an excellent energy resolution of similar to 3% at 662 keV and they have a relatively high light yield. LaBr3: Ce is being studied for application in TOF PET. At the same time, the search for and research on new scintillator materials are going on. For example, LuI(3): Ce is a new material with a very high light yield (similar to 90 000 photons MeV(-1)). Other examples of new materials are (C(6)H(13)NH(3))(2)PbI(4) and (C(3)H(7)NH(3))(2)PbBr(4), organic-inorganic hybrid compounds, of which the former has a very fast sub-nanosecond response. The new scintillators show great promise for new developments in medical applications, in particular, for PET systems.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [31] Characterization of scintillating fibers for use as positron detector in positron emission tomography
    Turgeon, Vincent
    Kertzscher, Gustavo
    Carroll, Liam
    Hopewell, Robert
    Massarweh, Gassan
    Enger, Shirin A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 114 - 120
  • [32] PIN PHOTODIODE-BASED MINIATURE GAMMA-RADIATION DETECTOR FOR MULTIPLE APPLICATIONS INCLUDING POSITRON EMISSION TOMOGRAPHY RADIOISOTOPES
    MCKINNEY, CJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 861 - 864
  • [33] Positron Emission Tomography: state of the art and future developments
    Pizzichemi, M.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [34] Positron emission tomography: Principles, technology, and recent developments
    Ziegler, SI
    NUCLEAR PHYSICS A, 2005, 752 : 679C - 687C
  • [35] CESIUM FLUORIDE - NEW DETECTOR FOR POSITRON EMISSION TOMOGRAPHY
    MULLANI, NA
    FICKE, DC
    TERPOGOSSIAN, MM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 572 - 575
  • [36] SAMPLING REQUIREMENTS AND DETECTOR MOTION FOR POSITRON EMISSION TOMOGRAPHY
    BROOKS, RA
    SANK, VJ
    TALBERT, AJ
    DICHIRO, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2760 - 2763
  • [37] Positron Emission Tomography Detector Development for Plant Biology
    Weisenberger, A. G.
    Kross, B.
    McKisson, J.
    Stolin, A.
    Zorn, C.
    Howell, C. R.
    Crowell, A. S.
    Reid, C. D.
    Majewski, S.
    Smith, M. F.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2323 - +
  • [38] Role of positron emission tomography in radiation oncology
    Freeman, Leonard M.
    Blaufox, M. Donald
    SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (02) : 103 - 104
  • [39] MEDICAL IMAGING BY MEANS OF POSITRON EMISSION TOMOGRAPHY
    TERPOGOSSIAN, MM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (08) : 590 - 590
  • [40] POSITRON EMISSION TOMOGRAPHY (PET) IN MEDICAL IMAGING
    Spasic-Jokic, Vesna
    ENVIRONMENTAL, HEALTH AND HUMANITY ISSUES IN THE DOWN DANUBIAN REGION: MULTIDISCIPLINARY APPROACHES, 2009, : 15 - 24