Storage Phosphors for Medical Imaging

被引:157
|
作者
Leblans, Paul [1 ]
Vandenbroucke, Dirk [1 ]
Willems, Peter [2 ]
机构
[1] Agfa HealthCare NV, B-2640 Mortsel, Belgium
[2] Ind Sci & Comp BVBA, B-9190 Stekene, Belgium
关键词
computed radiography; storage phosphor; X-ray; optically stimulated lumi-nescence; BaFBr:Eu2+; CsBr:Eu2+; needle imaging plate; image quality; COMPUTED RADIOGRAPHY SYSTEMS; RADIATION-INDUCED DEFECTS; PHOTOSTIMULATED LUMINESCENCE; STIMULATED LUMINESCENCE; HOLE-CENTERS; F-CENTERS; DIGITAL RADIOGRAPHY; ELECTRON; PERFORMANCE; MECHANISM;
D O I
10.3390/ma4061034
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Computed radiography (CR) uses storage phosphor imaging plates for digital imaging. Absorbed X-ray energy is stored in crystal defects. In read-out the energy is set free as blue photons upon optical stimulation. In the 35 years of CR history, several storage phosphor families were investigated and developed. An explanation is given as to why some materials made it to the commercial stage, while others did not. The photo stimulated luminescence mechanism of the current commercial storage phosphors, BaFBr:Eu2+ and CsBr:Eu2+ is discussed. The relation between storage phosphor plate physical characteristics and image quality is explained. It is demonstrated that the morphology of the phosphor crystals in the CR imaging plate has a very significant impact on its performance.
引用
收藏
页码:1034 / 1086
页数:53
相关论文
共 50 条
  • [41] New storage phosphors for thermal neutron detection
    A. V. Sidorenko
    P. A. Rodnyi
    C. W. E. van Eijk
    Technical Physics Letters, 2003, 29 : 586 - 588
  • [42] Phosphors and scintillators in radiation imaging detectors
    Tyrrell, GC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 180 - 187
  • [43] COMPUTED RADIOGRAPHIC IMAGING WITH PHOTOSTIMULABLE PHOSPHORS
    MERRITT, CRB
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (08) : C338 - C339
  • [44] Energy-Trapping Management in X-Ray Storage Phosphors for Flexible 3D Imaging
    Zhou, Xinquan
    Han, Kai
    Wang, Yexin
    Jin, Jiance
    Jiang, Shangda
    Zhang, Qinyuan
    Xia, Zhiguo
    ADVANCED MATERIALS, 2023, 35 (16)
  • [45] ZBLAN-based X-ray storage phosphors and scintillators for digital X-ray imaging
    Chen, G
    Johnson, JA
    Weber, R
    Schweizer, S
    MacFarlane, D
    Woodford, J
    De Carlo, F
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1351 - 1358
  • [46] Modeling the effect of light generation and light attenuation properties on the performance of phosphors used in medical imaging radiation detectors
    Kandarakis, I
    Cavouras, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (2-3): : 412 - 423
  • [47] X-RAY STORAGE PHOSPHORS, THEIR PROPERTIES AND MECHANISM
    SU, MZ
    ZHAO, W
    CHEN, W
    DONG, Y
    LIN, JH
    JOURNAL OF ALLOYS AND COMPOUNDS, 1995, 225 (1-2) : 539 - 543
  • [48] Physics and application of x-ray storage phosphors
    Winnacker, A
    TENTH FEOFILOV SYMPOSIUM ON SPECTROSCOPY OF CRYSTALS ACTIVATED BY RARE-EARTH AND TRANSITIONAL-METAL IONS, 1996, 2706 : 150 - 157
  • [49] X-ray storage phosphors, their properties and mechanism
    Su, M.-Z.
    Zhao, W.
    Chen, W.
    Dong, Y.
    Lin, J.-H.
    Journal of Alloys and Compounds, 1995, 225
  • [50] New synthesis of high-quality storage phosphors
    von Seggern, Heinz
    Hesse, Sabine
    Zimmermann, Joerg
    Appleby, Graham A.
    Meng, Xianguo
    Fasel, Claudia
    Riedel, Ralf
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 478 - 484