computed radiography; storage phosphor; X-ray; optically stimulated lumi-nescence; BaFBr:Eu2+; CsBr:Eu2+; needle imaging plate; image quality; COMPUTED RADIOGRAPHY SYSTEMS; RADIATION-INDUCED DEFECTS; PHOTOSTIMULATED LUMINESCENCE; STIMULATED LUMINESCENCE; HOLE-CENTERS; F-CENTERS; DIGITAL RADIOGRAPHY; ELECTRON; PERFORMANCE; MECHANISM;
D O I
10.3390/ma4061034
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Computed radiography (CR) uses storage phosphor imaging plates for digital imaging. Absorbed X-ray energy is stored in crystal defects. In read-out the energy is set free as blue photons upon optical stimulation. In the 35 years of CR history, several storage phosphor families were investigated and developed. An explanation is given as to why some materials made it to the commercial stage, while others did not. The photo stimulated luminescence mechanism of the current commercial storage phosphors, BaFBr:Eu2+ and CsBr:Eu2+ is discussed. The relation between storage phosphor plate physical characteristics and image quality is explained. It is demonstrated that the morphology of the phosphor crystals in the CR imaging plate has a very significant impact on its performance.
引用
收藏
页码:1034 / 1086
页数:53
相关论文
共 50 条
  • [21] Modeling quantum noise of phosphors used in medical X-ray imaging detectors
    Kalivas, N
    Kandarakis, I
    Cavouras, D
    Costaridou, L
    Nomicos, CD
    Panayiotakis, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 430 (2-3): : 559 - 569
  • [22] Modeling quantum noise of phosphors used in medical X-ray imaging detectors
    Kalivas, N.
    Kandarakis, I.
    Cavouras, D.
    Costaridou, L.
    Nomicos, C.D.
    Panayiotakis, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 430 (2-3): : 559 - 569
  • [23] THE USE OF STORAGE PHOSPHORS FOR PORTAL IMAGING IN RADIATION-THERAPY - THERAPISTS PERCEPTION OF IMAGE QUALITY
    GUR, D
    DEUTSCH, M
    FUHRMAN, CR
    CLAYTON, PA
    WEISER, JC
    ROSENTHAL, MS
    BUKOVITZ, AG
    MEDICAL PHYSICS, 1989, 16 (01) : 132 - 136
  • [24] MEASUREMENT SYSTEMS FOR THE CHARACTERIZATION OF PHOTOSTIMULABLE PHOSPHORS AND STORAGE PHOSPHOR SCREENS FOR X-RAY-IMAGING
    STRUYE, L
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) : C390 - C390
  • [25] Optimization of Data Storage Performance in Medical PACS Imaging System
    You, Lijue
    Jiao, Shengpin
    Li, Xiaoyong
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2024, 58 (10): : 1629 - 1636
  • [26] Phosphors and Scintillators in Biomedical Imaging
    Michail, Christos
    Liaparinos, Panagiotis
    Kalyvas, Nektarios
    Kandarakis, Ioannis
    Fountos, George
    Valais, Ioannis
    CRYSTALS, 2024, 14 (02)
  • [27] A Storage Retrieval Method of Medical Imaging Based on XML Description
    Xia, Lei
    Wan, Liyong
    PROCEEDINGS OF THE 2016 2ND WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS, 2016, 81 : 833 - 836
  • [28] ABSORPTION, EMISSION AND STORAGE OF ENERGY IN PHOSPHORS
    GARLICK, GFJ
    BRITISH JOURNAL OF APPLIED PHYSICS, 1955, : S85 - S90
  • [29] X-ray storage phosphors
    Spaeth, JM
    Hangleiter, T
    Koschnick, FK
    Pawlik, T
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1995, 135 (1-4): : 499 - 508
  • [30] ENERGY STORAGE IN ZNS AND ZNCDS PHOSPHORS
    KALLMANN, H
    SUCOV, E
    PHYSICAL REVIEW, 1958, 109 (05): : 1473 - 1478