PET and parathyroid L-[carbon-11]methionine accumulation in hyperparathyroidism

被引:0
|
作者
Sundin, A
Johansson, C
Hellman, P
Bergstrom, M
Ahlstrom, H
Jacobson, GB
Langstrom, B
Rastad, J
机构
[1] UNIV UPPSALA,PET CTR,UPPSALA,SWEDEN
[2] DEPT DIAGNOST RADIOL,UPPSALA,SWEDEN
[3] DEPT SURG,UPPSALA,SWEDEN
关键词
PET; carbon-11-methionine; parathyroid gland; hyperparathyroidism;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study was designed to characterize L-[methyl-C-11]methionine accumulation in abnormal parathyroid tissues of hyperparathyroidism (HPT). Methods: Thirty-four patients with primary (n=32) or secondary HPT were investigated with PET before primary or reoperative (n=25) parathyroid surgery. Parathyroid C-11-methionine accumulation was analyzed for integrated uptake values in defined tissue volumes standardized for the injected dose and body weight (SUV), four contiguous pixels of maximal accumulation (SUVhs), SUV multiplied by area of region of interest (SUVr) and by the excised tissue weight (SUVw). Transport rate constants (slope, slope(hs)) were calculated according to Patlak's formula using plasma C-11 activity corrected for C-11-methionine metabolites. Results: True-positive localization was achieved in 85% of patients in whom 81% of the excised parathyroid lesions were visualized; no false-positive results were obtained, Corresponding proportions were 59% and 57% for CT and 55% and 52% for ultrasound, respectively. In the true-positive cases, parathyroid SUV, SUVhs and transport rate constants were consistently higher (p <0.01) than in the thyroid, pharynx-esophagus, neck muscle and apical lung. Parathyroid SUV, SUVhs and SUVr increased with intact serum parathyroid hormone and calcium values (p=0.0001-0.031), and weight of the excised tissue correlated with SUV and SUVhs (p=0.024, 0.044). Parathyroid SUVhs varied strongly with the transport rate constants (p=0.0008), and SUVr as well as s-calcium values differed significantly between parathyroid adenomas (n=11), chief cell hyperplasias(n=13), inadvertent implants (n=3) and parathyroid cancers (n=3). Conclusion: Carbon-11-methionine PET has potential application in preoperative localization and metabolic characterization of abnormal parathyroid tissues in human HPT.
引用
收藏
页码:1766 / 1770
页数:5
相关论文
共 50 条
  • [21] Evaluation of C-11-methionine-PET/MRI in primary hyperparathyroidism
    Eberhardt, Nina
    Steinacker, Jochen
    Hillenbrand, Andreas
    Muller-Reinartz, Anja
    Michalski, Christoph
    Korf, Patrick
    Beer, Meinrad
    Solbach, Christoph
    Kull, Thomas
    Beer, Ambros
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [22] PET studies with carbon-11 radioligands in neuropsychopharmacological drug development
    Halldin, C
    Gulyás, B
    Farde, L
    CURRENT PHARMACEUTICAL DESIGN, 2001, 7 (18) : 1907 - 1929
  • [23] Methods for the Incorporation of Carbon-11 To Generate Radiopharmaceuticals for PET Imaging
    Scott, Peter J. H.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (33) : 6001 - 6004
  • [24] Asymmetric Synthesis of Carbon-11 Labelled α-Amino Acids for PET
    Popkov, Alexander
    Elsinga, Philip H.
    CURRENT ORGANIC CHEMISTRY, 2013, 17 (19) : 2127 - 2137
  • [25] Prospective PET study with 11C-methionine in patients with hyperparathyroidism
    Otto, D
    Behrend, M
    Börner, AR
    Oetting, G
    Weckesser, E
    Hofmann, M
    Petrich, T
    Knapp, WH
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1056 - 1056
  • [26] Normal variants, artefacts and interpretative pitfalls in PET imaging with 18-fluoro-2-deoxyglucose and carbon-11 methionine
    Cook, GJR
    Maisey, MN
    Fogelman, I
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (10) : 1363 - 1378
  • [27] Evaluation of C-11-methionine-PET/MRI in primary hyperparathyroidism
    Eberhardt, N.
    Steinacker, J. P.
    Hillenbrand, A.
    Mueller-Reinartz, A.
    Michalski, C.
    Korf, P.
    Beer, M.
    Solbach, C.
    Kull, T.
    Beer, A. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S384 - S385
  • [28] Carbon-11 acetate PET imaging of prostate cancer.
    Shreve, PD
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 60P - 60P
  • [29] Preoperative PET with 11C-methionine in patients with hyperparathyroidism.
    Otto, D
    Behrend, M
    Börner, AR
    Oetting, G
    Weckesser, E
    Hofmann, M
    Knapp, WH
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 160P - 160P
  • [30] Carbon-11 acetate PET imaging in recurrent prostate cancer
    Waldert, M
    Wachter, S
    Djavan, B
    Becherer, A
    Seitz, C
    Dudczak, R
    Kletter, K
    Lorang, T
    Kurtaran, A
    JOURNAL OF UROLOGY, 2002, 167 (04): : 304 - 304