共 50 条
Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry
被引:60
|作者:
Yu, Jie
[1
]
Yang, Shuxiu
[1
]
Sun, Duixiong
[2
,3
]
Lu, Quanfang
[1
,3
]
Zheng, Jidong
[1
]
Zhang, Xiaomei
[1
]
Wang, Xing
[1
]
机构:
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Coll Phys & Elect Engn, Key Lab Atom & Mol Phys & Funct Mat Gansu Prov, Lanzhou 730070, Peoples R China
[3] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Liquid cathode glow discharge (LCGD);
Atomic emission spectrometry (AES);
Determination;
Metal elements;
Water samples;
TRACE HEAVY-METALS;
ATMOSPHERIC-PRESSURE;
ELECTROLYTE-SOLUTIONS;
IMPROVED SENSITIVITY;
EXCITATION SOURCE;
FORMIC-ACID;
PLASMA;
SPECTROSCOPY;
IMPROVEMENT;
SURFACTANTS;
D O I:
10.1016/j.microc.2016.05.019
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
In this work, a liquid cathode glow discharge-atomic emission spectrometry (LCGD-AES) was constructed for simultaneously determination of K, Na, Ca, Mg and Zn in water samples (tap water, mineral water, Yellow River water and waste water), in which the glow discharge plasma was produced between the needle-like Pt anode and electrolyte around a quartz capillary cathode. The effects of the supporting electrolyte, discharge voltage and organic additives on emission intensity were investigated in detail. The limits of detections (LODs) of metals were compared with those measured by the closed-type electrolyte-cathode discharge-atomic emission spectrometry (ELCAD-AES). In addition, the measured results of water samples using LCGD-were verified by ICP. The results showed that the optimal operation conditions are pH = 1 HNO3 as supporting electrolyte, addition of 0.15% formic acid and 650 V discharge voltage. The R-2 and the RSD are ranged from 0.9887 to 0.9990 and 1.10% to 2.19%, respectively. LODs of K, Na, Ca, Mg and Zn are 0.02, 0.04, 0.19, 0.04 and 0.05 mg L-1, which are in agreement with the ELCAD-AES, and satisfied the recommended levels of the China standards for drinking water quality. The obtained results of Na, K, Ca, Mg and Zn in water samples by LCGD and ICP have certain difference. This result provides an alternative analytical method for the determination of metal elements in water samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 330
页数:6
相关论文