Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry

被引:60
|
作者
Yu, Jie [1 ]
Yang, Shuxiu [1 ]
Sun, Duixiong [2 ,3 ]
Lu, Quanfang [1 ,3 ]
Zheng, Jidong [1 ]
Zhang, Xiaomei [1 ]
Wang, Xing [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Coll Phys & Elect Engn, Key Lab Atom & Mol Phys & Funct Mat Gansu Prov, Lanzhou 730070, Peoples R China
[3] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid cathode glow discharge (LCGD); Atomic emission spectrometry (AES); Determination; Metal elements; Water samples; TRACE HEAVY-METALS; ATMOSPHERIC-PRESSURE; ELECTROLYTE-SOLUTIONS; IMPROVED SENSITIVITY; EXCITATION SOURCE; FORMIC-ACID; PLASMA; SPECTROSCOPY; IMPROVEMENT; SURFACTANTS;
D O I
10.1016/j.microc.2016.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a liquid cathode glow discharge-atomic emission spectrometry (LCGD-AES) was constructed for simultaneously determination of K, Na, Ca, Mg and Zn in water samples (tap water, mineral water, Yellow River water and waste water), in which the glow discharge plasma was produced between the needle-like Pt anode and electrolyte around a quartz capillary cathode. The effects of the supporting electrolyte, discharge voltage and organic additives on emission intensity were investigated in detail. The limits of detections (LODs) of metals were compared with those measured by the closed-type electrolyte-cathode discharge-atomic emission spectrometry (ELCAD-AES). In addition, the measured results of water samples using LCGD-were verified by ICP. The results showed that the optimal operation conditions are pH = 1 HNO3 as supporting electrolyte, addition of 0.15% formic acid and 650 V discharge voltage. The R-2 and the RSD are ranged from 0.9887 to 0.9990 and 1.10% to 2.19%, respectively. LODs of K, Na, Ca, Mg and Zn are 0.02, 0.04, 0.19, 0.04 and 0.05 mg L-1, which are in agreement with the ELCAD-AES, and satisfied the recommended levels of the China standards for drinking water quality. The obtained results of Na, K, Ca, Mg and Zn in water samples by LCGD and ICP have certain difference. This result provides an alternative analytical method for the determination of metal elements in water samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 50 条
  • [21] Analytical Performance of Hollow Anode-Solution Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng, Peichao
    Li, Weiqi
    Wang, Jinmei
    Wang, Ningshen
    Zhong, Chao
    Luo, Yuanjiang
    Wang, Xiaofa
    Mao, Xuefeng
    Lai, Chunhong
    ANALYTICAL LETTERS, 2020, 53 (05) : 693 - 704
  • [22] Determination of Trace Metals in Lutetium-Yttrium Orthosilicate by Solution-Cathode Glow Discharge-Atomic Emission Spectrometry
    Gai Rong-Yin
    Wang Zheng
    He Yan-Feng
    Li Qing
    Zou Hui-Jun
    Zhang Guo-Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (11) : 1617 - 1622
  • [23] Ultratrace Pb determination in seawater by solution-cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Cheng, Junqi
    Li, Qing
    Zhao, Mingyue
    Wang, Zheng
    ANALYTICA CHIMICA ACTA, 2019, 1077 : 107 - 115
  • [24] Determination of Aqueous Potassium and Sodium Ions with Liquid-Phase Diaphragm Glow Discharge-Atomic Emission Spectrometry
    Liu Yong-jun
    Wang Lei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (09) : 2570 - 2573
  • [25] Sensitive Determination of Alkali Metals by Liquid Anode Glow Discharge-Atomic Emission Spectrometry (LAGD-AES)
    Yu, Jie
    Wang, Kai
    Feng, Yan
    Hao, Xiaoxia
    Li, Xuehe
    Lu, Quanfang
    ANALYTICAL LETTERS, 2024,
  • [26] Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity
    Zhang, Zhen
    Wang, Zheng
    Li, Qing
    Zou, Huijun
    Shi, Ying
    TALANTA, 2014, 119 : 613 - 619
  • [27] Liquid Cathode Glow Discharge as a Microplasma Excitation Source for Atomic Emission Spectrometry for the Determination of Trace Heavy Metals in Ore Samples
    Yu, Jie
    Zhu, Shuwen
    Lu, Quanfang
    Zhang, Zhichao
    Sun, Duixiong
    Zhang, Xiaomin
    Wang, Xing
    Yang, Wu
    ANALYTICAL LETTERS, 2018, 51 (13) : 2128 - 2140
  • [28] Evaluation of analytical performance for the simultaneous detection of trace Cu, Co and Ni by using liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Sun, Duixiong
    Wang, Xing
    Zhu, Shuwen
    Zhang, Zhichao
    Yang, Wu
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 145 : 64 - 70
  • [29] DETERMINATION OF LITHIUM ION BY LIQUID-PHASE DIAPHRAGM GLOW DISCHARGE-ATOMIC EMISSION SPECTROSCOPY
    Liu, Yongjun
    Sun, Bing
    Wang, Lei
    ANALYTICAL LETTERS, 2014, 47 (08) : 1409 - 1420
  • [30] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422