Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry

被引:60
|
作者
Yu, Jie [1 ]
Yang, Shuxiu [1 ]
Sun, Duixiong [2 ,3 ]
Lu, Quanfang [1 ,3 ]
Zheng, Jidong [1 ]
Zhang, Xiaomei [1 ]
Wang, Xing [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Coll Phys & Elect Engn, Key Lab Atom & Mol Phys & Funct Mat Gansu Prov, Lanzhou 730070, Peoples R China
[3] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid cathode glow discharge (LCGD); Atomic emission spectrometry (AES); Determination; Metal elements; Water samples; TRACE HEAVY-METALS; ATMOSPHERIC-PRESSURE; ELECTROLYTE-SOLUTIONS; IMPROVED SENSITIVITY; EXCITATION SOURCE; FORMIC-ACID; PLASMA; SPECTROSCOPY; IMPROVEMENT; SURFACTANTS;
D O I
10.1016/j.microc.2016.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a liquid cathode glow discharge-atomic emission spectrometry (LCGD-AES) was constructed for simultaneously determination of K, Na, Ca, Mg and Zn in water samples (tap water, mineral water, Yellow River water and waste water), in which the glow discharge plasma was produced between the needle-like Pt anode and electrolyte around a quartz capillary cathode. The effects of the supporting electrolyte, discharge voltage and organic additives on emission intensity were investigated in detail. The limits of detections (LODs) of metals were compared with those measured by the closed-type electrolyte-cathode discharge-atomic emission spectrometry (ELCAD-AES). In addition, the measured results of water samples using LCGD-were verified by ICP. The results showed that the optimal operation conditions are pH = 1 HNO3 as supporting electrolyte, addition of 0.15% formic acid and 650 V discharge voltage. The R-2 and the RSD are ranged from 0.9887 to 0.9990 and 1.10% to 2.19%, respectively. LODs of K, Na, Ca, Mg and Zn are 0.02, 0.04, 0.19, 0.04 and 0.05 mg L-1, which are in agreement with the ELCAD-AES, and satisfied the recommended levels of the China standards for drinking water quality. The obtained results of Na, K, Ca, Mg and Zn in water samples by LCGD and ICP have certain difference. This result provides an alternative analytical method for the determination of metal elements in water samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 50 条
  • [11] Determination of silicate by hollow cathode glow discharge-atomic emission spectrometry with hydride generation technique
    Fujiwara, K
    Wagner, EP
    Smith, BW
    Winefordner, JD
    ANALYTICAL LETTERS, 1996, 29 (11) : 1985 - 1992
  • [12] Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk
    Hao Jun
    Wang Yu
    Liu Cong
    Wu Zan
    Shao Peng
    Zu Wen-chuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3797 - 3801
  • [13] Evaluation of flow injection-solution cathode glow discharge-atomic emission spectrometry for the determination of major elements in brines
    Yang, Chun
    Wang, Lin
    Zhu, Zhenli
    Jin, Lanlan
    Zheng, Hongtao
    Belshaw, Nicholas Stanley
    Hu, Shenghong
    TALANTA, 2016, 155 : 314 - 320
  • [14] Elemental Analysis of Mineral Water by Solution-Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng, Peichao
    Gong, Yaming
    Wang, Jinmei
    Zeng, Xiaobo
    ANALYTICAL LETTERS, 2017, 50 (09) : 1512 - 1520
  • [15] Determination of gallium in water samples by atomic emission spectrometry based on solution cathode glow discharge
    Li, Hongwei
    Zu, Wenchuan
    Liu, Fengkui
    Wang, Yu
    Yang, Yin
    Yang, Xiaotao
    Liu, Cong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 152 : 25 - 29
  • [16] Determination of Strontium in Strontium-Rich Mineral Water Using Solution Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng Pei-chao
    Luo Yuan-jiang
    Wang Jin-mei
    Hu Qiang
    Yang Yang
    Mao Xue-feng
    Lai Chun-hong
    Feng Chu-hui
    He Yu-tong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (01) : 272 - 276
  • [17] Fundamental studies of electrolyte-as-cathode glow discharge-atomic emission spectrometry for the determination of trace metals in flowing water
    Park, YS
    Ku, SH
    Hong, SH
    Kim, HJ
    Piepmeier, EH
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) : 1167 - 1179
  • [18] Evaluation of open-air type electrolyte-as-cathode glow discharge-atomic emission spectrometry for determination of trace heavy metals in liquid samples
    Mottaleb, MA
    Woo, YA
    Kim, HJ
    MICROCHEMICAL JOURNAL, 2001, 69 (03) : 219 - 230
  • [19] Liquid Cathode Glow Discharge as an Excitation Source for the Analysis of Complex Water Samples with Atomic Emission Spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Yin, Ling
    Feng, Feifei
    Luo, Hui
    Kang, Yuejing
    ACS OMEGA, 2020, 5 (31): : 19541 - 19547
  • [20] Development of open-air type electrolyle-as-cathode glow discharge-atomic emission spectrometry for determination of trace metals in water
    Kim, HJ
    Lee, JH
    Kim, MY
    Cserfalvi, T
    Mezei, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) : 823 - 831