Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method

被引:173
|
作者
Dai, Xinhua [1 ]
Fang, Xiang [1 ]
Zhang, Chunmei [1 ]
Xu, Ruifeng [1 ]
Xu, Bei [1 ]
机构
[1] Natl Inst Metrol, Natl Res Ctr CRMs, Beijing 100013, Peoples R China
关键词
uric acid; serum; LC/ID-MS; candidate reference method;
D O I
10.1016/j.jchromb.2007.07.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Uric acid is an important diagnostic marker of catabolism of the purine nucleosides, and accurate measurements of serum uric acid are necessary for proper diagnosis of gout or renal disease appearance. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) has been described. An isotopically labeled internal standard, [1,3-N-15(2)] uric acid, was added to serum, followed by equilibration and protein removal clean up to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) analyses. (M-H)(-) ions at m/z 167 and 169 for uric acid and its labeled internal standard were monitored for LC/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for uric acid (Standard Reference Materials SRM909b) with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added uric acid. The method performed well against the established reference method of ion-exchange followed by derivatization isotope dilution (ID) gas chromatography mass spectrometry (ID-GC/MS). The results of this method for uric acid agreed well with the certified values and were within 0.10%. The amounts of uric acid recovered and added were in good agreement for the three concentrations. This method was applied to determine uric acid in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.08-0.18% and between-set CVs of 0.02-0.07% for LC/MS analyses. Liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analysis was also performed. The LC/MS and LC/MS/MS results were in very good agreement (within 0.14%). This LC/MS method, which demonstrates good accuracy and precision, and is in the speed of analysis without the need for a derivatization stage, qualifies as a candidate reference method. This method can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared. (c) 2007 Elsevier B.V. All fights reserved.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 50 条
  • [31] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Bachmann, Martina
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1301 - 1313
  • [32] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of zonisamide in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Wild, Janik
    Fischer, Vanessa
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1288 - 1300
  • [33] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [34] Accurate Quantification of Saccharin Using Isotope Dilution Liquid Chromatography Mass Spectrometry (ID-LC/MS)
    Lee, Yunjung
    Kim, Byungjoo
    Kim, Jeongkwon
    Ahn, Seonghee
    MASS SPECTROMETRY LETTERS, 2011, 2 (02) : 37 - 40
  • [35] The determination of lysergide (LSD) in urine by high-performance liquid chromatography-isotope dilution mass spectrometry (IDMS)
    White, SA
    Kidd, AS
    Webb, KS
    JOURNAL OF FORENSIC SCIENCES, 1999, 44 (02) : 375 - 379
  • [36] Determination of Contaminants in Polyolefin Recyclates by High-Performance Liquid Chromatography - Mass Spectrometry (HPLC-MS)
    Shi, Xiaonan
    Zhu, Xixi
    Jiang, Qing
    Ma, Tengzhou
    Du, Yiping
    Wu, Ting
    ANALYTICAL LETTERS, 2023, 56 (05) : 758 - 768
  • [37] Determination of total cholesterol in serum by liquid chromatography isotope dilution mass spectrometry
    Kock, R
    Delvoux, B
    Greilling, H
    CLINICAL CHEMISTRY, 1997, 43 (10) : 1896 - 1903
  • [38] ISOTOPE-DILUTION - HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A NEW TECHNIQUE FOR THE DEVELOPMENT OF REFERENCE METHODS - DETERMINATION OF CREATININE AND URIC-ACID IN HUMAN-SERUM
    SIEKMANN, L
    SIEKMANN, A
    MACKRODT, D
    JOHNEN, C
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 324 (3-4): : 279 - 280
  • [39] Simultaneous Determination of 11 β-Agonists in Human Urine Using High-Performance Liquid Chromatography/Tandem Mass Spectrometry with Isotope Dilution
    Wang, Xiaoli
    Guo, Tao
    Wang, Shanshan
    Yuan, Jinpeng
    Zhao, Rusong
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (03) : 213 - 218
  • [40] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Yufei Wang
    Tianjiao Zhang
    Haijian Zhao
    Weiyan Zhou
    Jie Zeng
    Jiangtao Zhang
    Chuanbao Zhang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2363 - 2371