Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method

被引:173
|
作者
Dai, Xinhua [1 ]
Fang, Xiang [1 ]
Zhang, Chunmei [1 ]
Xu, Ruifeng [1 ]
Xu, Bei [1 ]
机构
[1] Natl Inst Metrol, Natl Res Ctr CRMs, Beijing 100013, Peoples R China
关键词
uric acid; serum; LC/ID-MS; candidate reference method;
D O I
10.1016/j.jchromb.2007.07.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Uric acid is an important diagnostic marker of catabolism of the purine nucleosides, and accurate measurements of serum uric acid are necessary for proper diagnosis of gout or renal disease appearance. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) has been described. An isotopically labeled internal standard, [1,3-N-15(2)] uric acid, was added to serum, followed by equilibration and protein removal clean up to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) analyses. (M-H)(-) ions at m/z 167 and 169 for uric acid and its labeled internal standard were monitored for LC/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for uric acid (Standard Reference Materials SRM909b) with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added uric acid. The method performed well against the established reference method of ion-exchange followed by derivatization isotope dilution (ID) gas chromatography mass spectrometry (ID-GC/MS). The results of this method for uric acid agreed well with the certified values and were within 0.10%. The amounts of uric acid recovered and added were in good agreement for the three concentrations. This method was applied to determine uric acid in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.08-0.18% and between-set CVs of 0.02-0.07% for LC/MS analyses. Liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analysis was also performed. The LC/MS and LC/MS/MS results were in very good agreement (within 0.14%). This LC/MS method, which demonstrates good accuracy and precision, and is in the speed of analysis without the need for a derivatization stage, qualifies as a candidate reference method. This method can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared. (c) 2007 Elsevier B.V. All fights reserved.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 50 条
  • [21] Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS)
    Song, Hyemin
    Kim, Byungjoo
    Jeong, Hyuk
    Ahn, Seonghee
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (06): : 524 - 530
  • [22] Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry Candidate Reference Method for Total Testosterone in Human Serum
    Botelho, Julianne Cook
    Shacklady, Christopher
    Cooper, Hans C.
    Tai, Susan S. -C.
    Van Uytfanghe, Katleen
    Thienpont, Linda M.
    Vesper, Hubert W.
    CLINICAL CHEMISTRY, 2013, 59 (02) : 372 - 380
  • [23] SPECIFIC METHOD FOR DETERMINING URIC-ACID IN SERUM USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    LIM, CK
    PRYDE, DE
    LAWSON, AM
    JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB): : 711 - 720
  • [24] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the determination of acrylamide in potato chips
    Park, Sunyoung
    Kim, Byungjoo
    So, Hun-Young
    Kim, Yeong-Joon
    Kim, Jeongkwon
    Bulletin of the Korean Chemical Society, 2007, 28 (05) : 737 - 744
  • [25] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the determination of acrylamide in potato chips
    Park, Sunyoung
    Kim, Byungjoo
    So, Hun-Young
    Kim, Yeong-Joon
    Kim, Jeongkwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2007, 28 (05): : 737 - 744
  • [26] Development of isotope dilution–liquid chromatography/tandem mass spectrometry as a candidate reference method for the accurate determination of patulin in apple products
    Mohamed A. Gab-Allah
    Kihwan Choi
    Byungjoo Kim
    Analytical and Bioanalytical Chemistry, 2022, 414 : 1867 - 1879
  • [27] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY (HPLC/MS)
    GAMES, DE
    ADVANCES IN CHROMATOGRAPHY, 1983, 21 : 1 - 39
  • [28] Certification of Amyloid-Beta (Aβ) Certified Reference Materials by Amino Acid-Based Isotope Dilution High-Performance Liquid Chromatography Mass Spectrometry and Sulfur-Based High-Performance Liquid Chromatography Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
    Feng, Liuxing
    Huo, Zhongzhong
    Xiong, Jinping
    Li, Hongmei
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 13229 - 13237
  • [29] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of levetiracetam in human serum and plasma
    Kobel, Anja
    Schierscher, Tobias
    Singh, Neeraj
    Salzmann, Linda
    Liesch, Franziska
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1967 - 1977
  • [30] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of topiramate in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Kobel, Anja
    Fischer, Vanessa
    Schierscher, Tobias
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1942 - 1954