The Freiburg Stereoacuity Test: automatic measurement of stereo threshold

被引:30
|
作者
Bach, M [1 ]
Schmitt, C [1 ]
Kromeier, M [1 ]
Kommerell, G [1 ]
机构
[1] Univ Freiburg, Augenklin, Abt Neuroophthalmol & Schielbehandlung, D-79106 Freiburg, Germany
关键词
D O I
10.1007/s004170100317
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: There is a need for a stereotest with the following properties: (1) Natural viewing conditions, i.e. stimulus contours visible for each eye alone, but no or hardly any cue for monocular detection, and (2) suitability for threshold determination over a wide range of disparities. To comply with these requirements, we developed the Freiburg Stereoacuity Test. Method: The stimulus configuration is shown on a visual display unit (VDU) using phase-difference haploscopy with ferromagnetic liquid crystal shutters. The stereo target consists of a vertical bar that can be presented "in front of" or "behind" a frame. The sizes of the bar and the frame are kept constant relative to the stereo disparity. Anti-aliasing allows for disparities finer than the pixel raster. To mask monocular cues the bar is displaced randomly to the right or left. The stereo threshold was determined in two observers with normal eyes, using first the method of constant stimuli and then the best PEST. Both procedures were repeated with observers wearing scatter transparencies that reduced their visual acuity to about 1/10. In addition, the two observers with insight into the test design and two strabismic patients performed the best PEST procedure with one eye only. Results: With constant stimuli both observers achieved a stereoacuity of 2.6 arcsec and 3.1 arcsec, respectively, taking a hit rate of 75% as the threshold. The best PEST revealed a stereoacuity of 2.5 arcsec and 3.0 arcsec, respectively. The scatter transparencies raised the threshold to 261 and 257, respectively. With one eye only, the two observers with insight into the test design exploited the subtle position cue and reached a coarse pseudostereopsis. The two strabismic patients did not utilise the position cue. Conclusion: The Freiburg Stereoacuity Test allows determination of stereoacuity over a wide range of disparities (1-1000 arcsec). Although the stimuli can be seen with each eye alone, monocular depth cues are sufficiently masked. The Freiburg Stereoacuity Test is available at http://www.ukl.uni-frei-burg.de/aug/bach/fst/.
引用
收藏
页码:562 / 566
页数:5
相关论文
共 50 条
  • [1] The Freiburg Stereoacuity Test: automatic measurement of stereo threshold
    Michael Bach
    Christina Schmitt
    Miriam Kromeier
    Guntram Kommerell
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 562 - 566
  • [2] The Freiburg Visual Acuity test - Automatic measurement of visual acuity
    Bach, M
    OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) : 49 - 53
  • [3] Freiburg visual acuity test - automatic measurement of visual acuity
    Bach, Michael
    Optometry and Vision Science, 1996, 73 (01):
  • [4] THE AUTOMATIC TONE DECAY TEST AS PART OF DYNAMIC MEASUREMENT OF THRESHOLD
    LEHNHARDT, E
    BATTMER, RD
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY-ARCHIV FUR OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1980, 226 (03): : 155 - 160
  • [5] AUTOMATIC MEASUREMENT OF OPERATING THRESHOLD OF A THYRISTOR
    SAVRUKHIN, AP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (06): : 1477 - +
  • [6] Automatic Measurement of Fish Size Using Stereo Vision
    Perez, Daniel
    Ferrero, Francisco J.
    Alvarez, Ignacio
    Valledor, Marta
    Campo, Juan C.
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 1950 - 1955
  • [7] The automatic 'Freiburg Visual Acuity Test' used before and after cataract surgery
    Rover, J
    Bornkessel, HC
    Nisius, A
    Bach, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 209 (05) : 315 - 316
  • [8] Effect of induced anisometropia on stereoacuity assessed with the Randot® Preschool Stereoacuity Test
    Fern, KD
    Wang, LIL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S429 - S429
  • [9] The Freiburg monosyllabic test put to the test
    Baljic, I.
    Hoppe, U.
    HNO, 2016, 64 (08) : 538 - 539
  • [10] Automatic Measurement of the Mechanical Part Based on Binocular Stereo Vision
    Guo, Jin
    Liu, Xianyong
    Chen, Xiaoning
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 8487 - 8491