Design and validation of an ultrasound array optimised for epidural needle guidance

被引:1
|
作者
Cochran, S. [1 ]
Corner, G. A. [2 ]
Kirk, Y. J. [3 ]
Lineo, D. I. A. [4 ]
Watson, M. J. [5 ]
机构
[1] Univ Dundee, Inst Med Sci & Technol, Dundee, Scotland
[2] Ninewells Hosp, Dept Phys Med, Dundee, Scotland
[3] Univ Paisley, Microscale Sensors, Paisley, Renfrew, Scotland
[4] Diagnost Sonar Ltd, Livingston, Scotland
[5] Greater Glasgow & Clyde Hlth Board, Glasgow, Lanark, Scotland
关键词
needle guidance; epidural anaesthesia; ultrasound array;
D O I
10.1109/ULTSYM.2007.567
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Frequent use Is made of lumbar epidural and combined spinal epidural anaesthesia and analgesia for pain relief during labour and childbirth. However, the conventional use of palpation to identify the position of the relevant interspinous space can be difficult In obese parturients. The safety, low cost and capability for ultrasound to be used in real time at the point of care make it a suitable clinical imaging modality to use as an alternative. With a conventional biomedical ultrasound imaging array, with or without a needle guide, the needle cannot be made to lie exactly in the Imaging plane because of the physical geometry and with lengths up to more than 100 mm for lumbar epidural procedures, it is easy for the needle to leave the imaging plane altogether. The work reported here has been directed towards a practical solution to this problem via custom array design. This takes Into account the need for ergonomic manipulation by the anaesthetist, insertion of the needle exactly parallel to the ultrasonic beam, and sterility. The array Incorporates two separate electroacoustic components with a space for needle insertion in between. Using standard array modules has allowed this novel configuration to be connected to a conventional Imaging system with only minimal software modifications. The array is operated with its body parallel to the obese parturient's back and with an optimised clinical procedure. The procedure first involves use of the array to identify the relevant Interspinous space, followed by insertion of the needle through the array, which is subsequently held in place to guide the needle tip until contact is established with the spine or can be withdrawn once the needle path is well established.
引用
收藏
页码:2255 / +
页数:2
相关论文
共 50 条
  • [41] Automatic Localization of the Needle Target for Ultrasound-Guided Epidural Injections
    Pesteie, Mehran
    Lessoway, Victoria
    Abolmaesumi, Purang
    Rohling, Robert N.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (01) : 81 - 92
  • [42] Ultrasound Guided Automatic Localization of Needle Insertion Site for Epidural Anesthesia
    Yu, Shuang
    Tan, Kok Kiong
    Shen, Chengyao
    Sia, Alex Tiong Heng
    2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2013, : 985 - 990
  • [43] System for epidural needle guidance enabled by fiber-optics distributed shape sensing
    Molardi, Carlo
    Amantayeva, Aida
    Adilzhanova, Nargiz
    Blanc, Wilfried
    Tosi, Daniele
    OPTICAL SENSING AND DETECTION VII, 2022, 12139
  • [44] Ultrasound guidance increases diagnostic yield of needle EMG in plegic muscle
    Gentile, Luca
    Coraci, Daniele
    Pazzaglia, Costanza
    Del Tedesco, Filippo
    Erra, Carmen
    Le Pera, Domenica
    Padua, Luca
    CLINICAL NEUROPHYSIOLOGY, 2020, 131 (02) : 446 - 450
  • [45] 3D ultrasound guidance system for needle placement procedures
    Xu, Sheng
    Kruecker, Jochen
    Jiang, Hui
    Settlemier, Scott
    Glossop, Neil
    Aradhana, Venkatesan
    Kam, Anthony
    Wood, Bradford
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [46] Transrectal ultrasound for intraoperative interstitial needle guidance in cervical cancer brachytherapy
    Knoth, J.
    Sturdza, A.
    Zaharie, A.
    Dick, V.
    Kronreif, G.
    Nesvacil, N.
    Widder, J.
    Kirisits, C.
    Schmid, M. P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (08) : 684 - 690
  • [47] ULTRASOUND NEEDLE GUIDANCE FOR AMNIOCENTESIS IN PREGNANCIES WITH LOW AMNIOTIC-FLUID
    MCGAHAN, JP
    TENNANT, F
    HANSON, FW
    LINDFORS, KK
    QUILLIGAN, EJ
    JOURNAL OF REPRODUCTIVE MEDICINE, 1987, 32 (07) : 513 - 516
  • [48] CUTTING NEEDLE-BIOPSY OF THORACIC LESIONS UNDER ULTRASOUND GUIDANCE
    PANG, J
    TSANG, V
    METREWELI, C
    CHEST, 1986, 89 (06) : S449 - S449
  • [49] A Novel Method for Enhanced Needle Localization Using Ultrasound-Guidance
    Dong, Bin
    Savitsky, Eric
    Osher, Stanley
    ADVANCES IN VISUAL COMPUTING, PT 1, PROCEEDINGS, 2009, 5875 : 914 - +
  • [50] Design and Assessment of a Bimanual Haptic Epidural Needle Insertion Simulator
    Davidor, Nitsan
    Binyamin, Yair
    Kosovsky, Tamar Hayuni
    Nisky, Ilana