Design and validation of an ultrasound array optimised for epidural needle guidance

被引:1
|
作者
Cochran, S. [1 ]
Corner, G. A. [2 ]
Kirk, Y. J. [3 ]
Lineo, D. I. A. [4 ]
Watson, M. J. [5 ]
机构
[1] Univ Dundee, Inst Med Sci & Technol, Dundee, Scotland
[2] Ninewells Hosp, Dept Phys Med, Dundee, Scotland
[3] Univ Paisley, Microscale Sensors, Paisley, Renfrew, Scotland
[4] Diagnost Sonar Ltd, Livingston, Scotland
[5] Greater Glasgow & Clyde Hlth Board, Glasgow, Lanark, Scotland
关键词
needle guidance; epidural anaesthesia; ultrasound array;
D O I
10.1109/ULTSYM.2007.567
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Frequent use Is made of lumbar epidural and combined spinal epidural anaesthesia and analgesia for pain relief during labour and childbirth. However, the conventional use of palpation to identify the position of the relevant interspinous space can be difficult In obese parturients. The safety, low cost and capability for ultrasound to be used in real time at the point of care make it a suitable clinical imaging modality to use as an alternative. With a conventional biomedical ultrasound imaging array, with or without a needle guide, the needle cannot be made to lie exactly in the Imaging plane because of the physical geometry and with lengths up to more than 100 mm for lumbar epidural procedures, it is easy for the needle to leave the imaging plane altogether. The work reported here has been directed towards a practical solution to this problem via custom array design. This takes Into account the need for ergonomic manipulation by the anaesthetist, insertion of the needle exactly parallel to the ultrasonic beam, and sterility. The array Incorporates two separate electroacoustic components with a space for needle insertion in between. Using standard array modules has allowed this novel configuration to be connected to a conventional Imaging system with only minimal software modifications. The array is operated with its body parallel to the obese parturient's back and with an optimised clinical procedure. The procedure first involves use of the array to identify the relevant Interspinous space, followed by insertion of the needle through the array, which is subsequently held in place to guide the needle tip until contact is established with the spine or can be withdrawn once the needle path is well established.
引用
收藏
页码:2255 / +
页数:2
相关论文
共 50 条
  • [21] Using ultrasound in a case of difficult epidural needle placement
    Peng, PWH
    Rofaeel, A
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2006, 53 (03): : 325 - 326
  • [22] Using ultrasound in a case of difficult epidural needle placement
    Philip W.H Peng
    Ayman Rofaeel
    Canadian Journal of Anesthesia, 2006, 53 : 325 - 326
  • [23] Diagnostic Accuracy of Ultrasound Guidance in Transthoracic Needle Biopsy
    Lemieux, Simon
    Pinard, Lorence
    Marchand, Raphael
    Kali, Sonia
    Altmayer, Stephan
    Mai, Vicky
    Provencher, Steeve
    JOURNAL OF THORACIC IMAGING, 2025, 40 (02)
  • [24] FINE NEEDLE ASPIRATION OF THE LIVER AND PANCREAS WITH ULTRASOUND GUIDANCE
    BOGNEL, C
    ROUGIER, P
    LECLERE, J
    DUVILLARD, P
    CHARPENTIER, P
    PRADE, M
    ACTA CYTOLOGICA, 1988, 32 (01) : 22 - 26
  • [25] Did Tuohy design the epidural needle or was it Huber?
    Martini, J
    Martin, D
    Kamath, G
    Vasdev, G
    Anes, G
    ANESTHESIOLOGY, 2001, 94 (1A) : U18 - U18
  • [26] Ultrasound needle guidance in neonatal and infant caudal anesthesia
    Galante, Dario
    PEDIATRIC ANESTHESIA, 2008, 18 (12) : 1233 - 1234
  • [27] Four-dimensional ultrasound guidance during epidural anaesthesia
    Voloshin A.G.
    Journal of Ultrasound, 2015, 18 (2) : 135 - 142
  • [28] Adaptive ultrasound imaging of the lumbar spine for guidance of epidural anesthesia
    Tran, Denis
    Hor, King-Wei
    Lessoway, Victoria A.
    Kamani, Allaudin A.
    Rohling, Robert N.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (08) : 593 - 601
  • [29] Thoracic caudal epidural catheter localization using ultrasound guidance
    Bachman, Sarah A.
    Taenzer, Andreas H.
    PEDIATRIC ANESTHESIA, 2020, 30 (02) : 194 - 195
  • [30] The use of ultrasound improves the accuracy of epidural needle placement in cadavers
    Kessler, Jens
    Moriggl, Bernhard
    Grau, Thomas
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (07) : 695 - 703