Design and validation of an ultrasound array optimised for epidural needle guidance

被引:1
|
作者
Cochran, S. [1 ]
Corner, G. A. [2 ]
Kirk, Y. J. [3 ]
Lineo, D. I. A. [4 ]
Watson, M. J. [5 ]
机构
[1] Univ Dundee, Inst Med Sci & Technol, Dundee, Scotland
[2] Ninewells Hosp, Dept Phys Med, Dundee, Scotland
[3] Univ Paisley, Microscale Sensors, Paisley, Renfrew, Scotland
[4] Diagnost Sonar Ltd, Livingston, Scotland
[5] Greater Glasgow & Clyde Hlth Board, Glasgow, Lanark, Scotland
关键词
needle guidance; epidural anaesthesia; ultrasound array;
D O I
10.1109/ULTSYM.2007.567
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Frequent use Is made of lumbar epidural and combined spinal epidural anaesthesia and analgesia for pain relief during labour and childbirth. However, the conventional use of palpation to identify the position of the relevant interspinous space can be difficult In obese parturients. The safety, low cost and capability for ultrasound to be used in real time at the point of care make it a suitable clinical imaging modality to use as an alternative. With a conventional biomedical ultrasound imaging array, with or without a needle guide, the needle cannot be made to lie exactly in the Imaging plane because of the physical geometry and with lengths up to more than 100 mm for lumbar epidural procedures, it is easy for the needle to leave the imaging plane altogether. The work reported here has been directed towards a practical solution to this problem via custom array design. This takes Into account the need for ergonomic manipulation by the anaesthetist, insertion of the needle exactly parallel to the ultrasonic beam, and sterility. The array Incorporates two separate electroacoustic components with a space for needle insertion in between. Using standard array modules has allowed this novel configuration to be connected to a conventional Imaging system with only minimal software modifications. The array is operated with its body parallel to the obese parturient's back and with an optimised clinical procedure. The procedure first involves use of the array to identify the relevant Interspinous space, followed by insertion of the needle through the array, which is subsequently held in place to guide the needle tip until contact is established with the spine or can be withdrawn once the needle path is well established.
引用
收藏
页码:2255 / +
页数:2
相关论文
共 50 条
  • [1] Ultrasound guidance in caudal epidural needle placement
    Chen, CPC
    Tang, SFT
    Hsu, TC
    Tsai, WC
    Liu, HP
    Chen, MJL
    Date, E
    Lew, HL
    ANESTHESIOLOGY, 2004, 101 (01) : 181 - 184
  • [2] Disadvantages of ultrasound guidance in caudal epidural needle placement
    Huang, J
    ANESTHESIOLOGY, 2005, 102 (03) : 693 - 693
  • [3] Polyimide-Based Conformal Ultrasound Transducer Array for Needle Guidance
    Culjat, Martin O.
    Bennett, David B.
    Lee, Michael
    Brown, Elliott R.
    Lee, Hua
    Grundfest, Warren S.
    Singh, Rahul S.
    IEEE SENSORS JOURNAL, 2009, 9 (10) : 1244 - 1253
  • [4] Needle aspiration of epidural hematoma under real-time ultrasound guidance: letter to the editor
    Rena S. Kulieva
    Evgeniy Y. Kryukov
    Semen S. Sotnikov
    Danil A. Kozyrev
    Alexander S. Iova
    Child's Nervous System, 2023, 39 : 1999 - 2000
  • [5] Needle aspiration of epidural hematoma under real-time ultrasound guidance: letter to the editor
    Kulieva, Rena S.
    Kryukov, Evgeniy Y.
    Sotnikov, Semen S.
    Kozyrev, Danil A.
    Iova, Alexander S.
    CHILDS NERVOUS SYSTEM, 2023, 39 (08) : 1999 - 2000
  • [6] The epidural needle guidance with an intelligent and automatic identification system for Epidural Anesthesia
    Kao, Meng-Chun
    Ting, Chien-Kun
    Kuo, Wen-Chuan
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XVI, 2018, 10484
  • [7] Pioneers in epidural needle design
    Frölich, MA
    Caton, D
    ANESTHESIA AND ANALGESIA, 2001, 93 (01): : 215 - 220
  • [8] Epidural Needle Guidance Using Viscoelastic Tissue Response
    Simpson, Benjamin Scott
    Burns, Michael
    Dick, Robert P.
    Saager, Leif
    IEEE Journal of Translational Engineering in Health and Medicine, 2022, 10
  • [9] Epidural Needle Guidance Using Viscoelastic Tissue Response
    Simpson, Benjamin
    Burns, Michael
    Dick, Robert P.
    Saager, Leif
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2022, 10
  • [10] Preinsertion Paramedian Ultrasound Guidance for Epidural Anesthesia
    Tran, Denis
    Kamani, Allaudin A.
    Lessoway, Victoria A.
    Peterson, Carly
    Hor, King Wei
    Rohling, Robert N.
    ANESTHESIA AND ANALGESIA, 2009, 109 (02): : 661 - 667