Near Infrared Measurement of Cotton Fiber Micronaire by Portable Near Infrared Instrumentation

被引:15
|
作者
Rodgers, James [1 ]
Fortier, Chanel [1 ]
Montalvo, Joseph [1 ]
Cui, Xiaoliang [1 ]
Kang, Sho Yeung [2 ]
Martin, Vikki [3 ]
机构
[1] ARS, SRRC, USDA, New Orleans, LA USA
[2] Univ Georgia, Athens, GA 30602 USA
[3] Cotton Inc, Cary, NC USA
关键词
near infrared; cotton; micronaire; portable instrument;
D O I
10.1177/0040517510361799
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In the U. S. A., cotton is classed (primary quality parameters) by the Uster (R) High Volume Instrument (HVI), which must be maintained under tightly controlled laboratory environmental conditions. Improved and fast response quality measurement systems and tools are needed to rapidly assess the quality of cotton. One key area of emphasis and need is the development and implementation of new fast-response quality measurements that can be used not only in the laboratory but which also can be adapted to field and at-line quality measurements. A program was implemented to determine the ability of portable near-infrared (NIR) instrumentation to monitor critical fiber properties of cotton samples in the laboratory, at-line, and in the field, with initial emphasis on the laboratory measurement of cotton fiber micronaire. Micronaire is a key cotton property, and it is an indicator of the fiber's maturity and fineness. Distinct NIR spectral differences between samples with varying micronaire were observed. A comparative evaluation was performed to determine optimum instrumental conditions for laboratory cotton micronaire measurements. The comparative evaluation established that the optimum instrumental conditions for laboratory measurements of micronaire was obtained with the use of a glass-covered sampling port and increased instrumental gain, with high R-2 values, low residuals, and with <= 12% outliers. For a NIR measurement with potential for multiple simultaneous analyses and non-laboratory measurements, the micronaire measurement was fast (< 3 min per sample) and easy to perform. The rapid and accurate laboratory measurement of cotton fiber micronaire with portable NIR instrumentation was demonstrated.
引用
收藏
页码:1503 / 1515
页数:13
相关论文
共 50 条
  • [31] Near-infrared spectroscopy for measurement of total dietary fiber in homogenized meals
    Kim, Y
    Singh, M
    Kays, SE
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (02) : 292 - 298
  • [32] Study on Optical Fiber Carbon Monoxide Measurement System in Near Infrared Field
    Zhang Jie
    Wang Junhong
    Liu Jian
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION AND INSTRUMENTATION, VOL 4, 2008, : 1842 - 1845
  • [33] Instrumentation and calibration protocol for a continuous wave near infrared hemoximeter
    Salvatori, Giorgia
    Suh, K. I.
    Ansari, R. R.
    Rovati, Luigi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (04) : 1368 - 1376
  • [34] Near infrared
    不详
    CHEMISTRY WORLD, 2010, 7 (08): : 67 - 67
  • [35] Measurement of the near infrared xenon scintillation yield near atmospheric pressure
    Wilkerson, JA
    McLaren, J
    Raut, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 500 (1-3): : 345 - 350
  • [36] The blood beat measurement with near infrared ray
    Oshiro, Osamu
    Horio, Hideyuki
    Masuda, Yasushi
    IEEJ Transactions on Sensors and Micromachines, 2006, 126 (03) : 114 - 118
  • [37] Distance Measurement Using Near Infrared Sensors
    Rix, Bernold
    Nebeling, Andreas
    Raab, Tycho
    ENERGY CONSUMPTION AND AUTONOMOUS DRIVING, 2016, : 177 - 189
  • [38] Measurement of borneol based on near infrared spectroscopy
    Gu, XY
    Xu, KX
    Li, L
    Ling, NS
    Wang, Y
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (02) : 155 - 157
  • [39] An emissivity measurement apparatus for near infrared spectrum
    Zhang, Feng
    Yu, Kun
    Zhang, Kaihua
    Liu, Yanlei
    Xu, Kaipin
    Liu, Yufang
    INFRARED PHYSICS & TECHNOLOGY, 2015, 73 : 275 - 280
  • [40] Measurement of brain activity by near infrared light
    Eda, Hideo
    Journal of the National Institute of Information and Communications Technology, 2004, 51 (3-4): : 73 - 88