Near Infrared Measurement of Cotton Fiber Micronaire by Portable Near Infrared Instrumentation

被引:15
|
作者
Rodgers, James [1 ]
Fortier, Chanel [1 ]
Montalvo, Joseph [1 ]
Cui, Xiaoliang [1 ]
Kang, Sho Yeung [2 ]
Martin, Vikki [3 ]
机构
[1] ARS, SRRC, USDA, New Orleans, LA USA
[2] Univ Georgia, Athens, GA 30602 USA
[3] Cotton Inc, Cary, NC USA
关键词
near infrared; cotton; micronaire; portable instrument;
D O I
10.1177/0040517510361799
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In the U. S. A., cotton is classed (primary quality parameters) by the Uster (R) High Volume Instrument (HVI), which must be maintained under tightly controlled laboratory environmental conditions. Improved and fast response quality measurement systems and tools are needed to rapidly assess the quality of cotton. One key area of emphasis and need is the development and implementation of new fast-response quality measurements that can be used not only in the laboratory but which also can be adapted to field and at-line quality measurements. A program was implemented to determine the ability of portable near-infrared (NIR) instrumentation to monitor critical fiber properties of cotton samples in the laboratory, at-line, and in the field, with initial emphasis on the laboratory measurement of cotton fiber micronaire. Micronaire is a key cotton property, and it is an indicator of the fiber's maturity and fineness. Distinct NIR spectral differences between samples with varying micronaire were observed. A comparative evaluation was performed to determine optimum instrumental conditions for laboratory cotton micronaire measurements. The comparative evaluation established that the optimum instrumental conditions for laboratory measurements of micronaire was obtained with the use of a glass-covered sampling port and increased instrumental gain, with high R-2 values, low residuals, and with <= 12% outliers. For a NIR measurement with potential for multiple simultaneous analyses and non-laboratory measurements, the micronaire measurement was fast (< 3 min per sample) and easy to perform. The rapid and accurate laboratory measurement of cotton fiber micronaire with portable NIR instrumentation was demonstrated.
引用
收藏
页码:1503 / 1515
页数:13
相关论文
共 50 条
  • [21] Discrimination of plastics using a portable near infrared spectrometer
    Kumagai, M
    Suyama, H
    Sato, T
    Amano, T
    Ogawa, N
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2002, 10 (04) : 247 - 255
  • [22] The detection of soil parameters by portable near infrared spectrometer
    Li, Yufei
    Wang, Dacheng
    Zhang, Dongyan
    Zhu, Dazhou
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 718 - 726
  • [23] Development of Portable Plant Components Measurement Instrument Based on Near-infrared Spectroscopy
    Ma, Hao
    Ji, Haiyan
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 4163 - 4167
  • [24] Near infrared applications in the quality control of seed cotton
    Gaitan-Jurado, Antonio J.
    Garcia-Molina, Maria
    Pena-Rodriguez, Francisco
    Ortiz-Somovilla, Victor
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2008, 16 (04) : 421 - 429
  • [25] Analysis of sticky cotton by near-infrared spectroscopy
    Barton, FE
    Bargeron, JD
    Gamble, GR
    McAlister, DL
    Hequet, E
    APPLIED SPECTROSCOPY, 2005, 59 (11) : 1388 - 1392
  • [26] Tapered fiber sensor in the near infrared wavelength
    Li, Jiang-Yan
    MATERIALS SCIENCE-POLAND, 2019, 37 (03): : 324 - 330
  • [27] Near-Infrared Fiber Imager for the VLTI
    Neuhaeuser, Ralph
    Tuennermann, Andreas
    Hempel, Marc
    Stecklum, Bringfried
    Ruske, Jena-Peter
    Guenther, Eike
    Hatzes, Artie
    Chini, Rolf
    Lemke, Roland
    Wuchterl, Guenther
    von der Luehe, Oskar
    POWER OF OPTICAL/IR INTERFEROMETRY: RECENT SCIENTIFIC RESULTS AND 2ND GENERATION INSTRUMENTATION, 2008, : 419 - 429
  • [28] Polymer Optical Fiber for Near Infrared Use
    Takezawa, Yoshitaka
    Ohara, Shuichi
    Journal of Applied Polymer Science, 1993, 49 (01): : 169 - 173
  • [29] A Near Infrared Stokes Polarimeter for Fiber Applications
    Wang, Baoliang
    Leadbetter, Andy
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS IV, 2010, 7853
  • [30] Development and experiments of cotton moisture regain measurement using near-infrared method
    Chen Y.
    Yang S.
    Shi S.
    Zhao B.
    Wu T.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2021, 37 (07): : 158 - 165