Near Infrared Measurement of Cotton Fiber Micronaire by Portable Near Infrared Instrumentation

被引:15
|
作者
Rodgers, James [1 ]
Fortier, Chanel [1 ]
Montalvo, Joseph [1 ]
Cui, Xiaoliang [1 ]
Kang, Sho Yeung [2 ]
Martin, Vikki [3 ]
机构
[1] ARS, SRRC, USDA, New Orleans, LA USA
[2] Univ Georgia, Athens, GA 30602 USA
[3] Cotton Inc, Cary, NC USA
关键词
near infrared; cotton; micronaire; portable instrument;
D O I
10.1177/0040517510361799
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In the U. S. A., cotton is classed (primary quality parameters) by the Uster (R) High Volume Instrument (HVI), which must be maintained under tightly controlled laboratory environmental conditions. Improved and fast response quality measurement systems and tools are needed to rapidly assess the quality of cotton. One key area of emphasis and need is the development and implementation of new fast-response quality measurements that can be used not only in the laboratory but which also can be adapted to field and at-line quality measurements. A program was implemented to determine the ability of portable near-infrared (NIR) instrumentation to monitor critical fiber properties of cotton samples in the laboratory, at-line, and in the field, with initial emphasis on the laboratory measurement of cotton fiber micronaire. Micronaire is a key cotton property, and it is an indicator of the fiber's maturity and fineness. Distinct NIR spectral differences between samples with varying micronaire were observed. A comparative evaluation was performed to determine optimum instrumental conditions for laboratory cotton micronaire measurements. The comparative evaluation established that the optimum instrumental conditions for laboratory measurements of micronaire was obtained with the use of a glass-covered sampling port and increased instrumental gain, with high R-2 values, low residuals, and with <= 12% outliers. For a NIR measurement with potential for multiple simultaneous analyses and non-laboratory measurements, the micronaire measurement was fast (< 3 min per sample) and easy to perform. The rapid and accurate laboratory measurement of cotton fiber micronaire with portable NIR instrumentation was demonstrated.
引用
收藏
页码:1503 / 1515
页数:13
相关论文
共 50 条
  • [1] Measurement comparison of cotton fiber micronaire and its components by portable near infrared spectroscopy instruments
    Rodgers, James
    Zumba, Jimmy
    Fortier, Chanel
    [J]. TEXTILE RESEARCH JOURNAL, 2017, 87 (01) : 57 - 69
  • [2] Near Infrared Measurement of Cotton Fiber Micronaire, Maturity and Fineness - a Comparative Investigation
    Rodgers, James
    Montalvo, Joseph
    Davidonis, Gayle
    VonHoven, Terri
    [J]. TEXTILE RESEARCH JOURNAL, 2010, 80 (09) : 780 - 793
  • [3] Cotton Micronaire Measurements Using Small Portable Near-Infrared (NIR) Analyzers
    Zumba, Jimmy
    Rodgers, James
    [J]. APPLIED SPECTROSCOPY, 2016, 70 (05) : 794 - 803
  • [4] Impact of temperature and relative humidity on the near infrared spectroscopy measurements of cotton fiber micronaire
    Zumba, Jimmy
    Rodgers, James
    Indest, Matthew
    [J]. TEXTILE RESEARCH JOURNAL, 2018, 88 (20) : 2279 - 2291
  • [5] Measurement of cotton fiber numbers by near infrared spectroscopy
    He, Xiaofeng
    Wu, Guoxin
    Xu, Shoudong
    [J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2009, 25 (03): : 119 - 123
  • [6] Preliminary Field Measurement of Cotton Fiber Micronaire by Portable NIR
    Rodgers, James
    Kang, Sho Yeung
    Fortier, Chanel
    Cui, Xiaoliang
    Davidonis, Gayle
    Clawson, Ernest
    Boquet, Don
    Pettigrew, William
    [J]. SPECTROSCOPY, 2010, 25 (09) : 38 - 44
  • [7] Investigation of Fourier transform infrared spectroscopy potential in cotton fiber micronaire measurement and distribution
    Liu, Yongliang
    Delhom, Christopher D.
    [J]. TEXTILE RESEARCH JOURNAL, 2024, 94 (19-20) : 2178 - 2188
  • [8] RADIATIVE-TRANSFER MODEL FOR RELATING NEAR-INFRARED AND MICRONAIRE MEASUREMENTS OF COTTON FIBERS
    THOMASSON, JA
    MENGUC, MP
    SHEARER, SA
    [J]. TRANSACTIONS OF THE ASAE, 1995, 38 (02): : 367 - 377
  • [9] NEAR-INFRARED REFLECTANCE INSTRUMENTATION
    ROTOLO, P
    [J]. CEREAL FOODS WORLD, 1979, 24 (03) : 94 - 98
  • [10] Measurement of the Moisture Vaporization Enthalpy in Hair with Portable Near Infrared Spectrometer
    Takeyama, Maiko
    Kikuchi, Ryoei
    Kumagai, Masanori
    Amano, Toshio
    Ozeki, Toro
    Fujiwara, Kazuhiko
    Ogawa, Nobuaki
    [J]. BUNSEKI KAGAKU, 2009, 58 (08) : 667 - 673