Result of Ring Fixator in High-energy Schatzker Type VI Fractures of Proximal Tibia

被引:2
|
作者
Khanzada, Aftab Alam [1 ]
Joyo, Muhammad Rafique [2 ]
Javed, Muhammad Imran [3 ]
Ahmed, Nizam [4 ]
Keerio, Niaz Hussain [5 ]
Shah, Ghazanfar Ali [6 ]
Noor, Syed Shahid [7 ]
机构
[1] Indus Med Coll Tando Muhammad Khan, Tando Muhammad Khan, Pakistan
[2] Heerabad Hosp, Bone Care Trauma Ctr, Hyderabad, Pakistan
[3] Ruth Pfau Fazaia Med Coll, Karachi, Pakistan
[4] Liaquat Univ Med & Hlth Sci, Jamshoro, Pakistan
[5] Muhammad Med Coll & Hosp, Mirpurkhas, Pakistan
[6] Dow Univ Med & Hlth Sci, SMBBIT, Karachi, Pakistan
[7] Liaquat Natl Hosp & Med Coll, Karachi, Pakistan
关键词
external fixator; tibial plateau; schatzker VI; Ilizarov; fractures; WIRE EXTERNAL FIXATION; PLATEAU FRACTURES; INTERNAL-FIXATION; CLASSIFICATION; MANAGEMENT; REDUCTION;
D O I
10.9734/JPRI/2021/v33i43B32574
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Significant articular depression, separation of both condyles, diaphyseal comminution and dissociation, and loss of soft-tissue envelope integrity are all associated with high-energy proximal tibia fractures (Schatzker VI). Over the past 50 years, there has been a lot of research on plating problems in these complicated fractures. For the care of these complex injuries, Ilizarov devised a new method (ring fixator). Aim of the Study: To examine the outcomes of patients who received a ring fixator for the treatment of high-energy proximal tibia fractures (Schatzker VI). Materials and Methods: Fourteen patients (mean age 36) were treated with the Ilizarov fixator and transfixion wires for high-energy fractures of the proximal tibia (Schatzker VI). Nine of the patients had open fractures, and five of them had significant soft tissue damage. They were all tracked for an average of 19.4 months. The result was analyzed using the criteria set by Honkonen & Jarvinen (1992). Results: Thirteen fractures healed in an average of 14.6 weeks, with one taking six months. Twelve patients recovered complete extension, while eight others regained more than 110 degrees of flexion. All of the patients knees were stable, except one who had a minor varus deformity. Nine patients walked normally, while four had a little limp. Except for one, all of the knees exhibited an articular step-off of less than 4 mm and normal axial alignment. Six knees were found to be outstanding, five to be decent, and three to be fair. There were no instances of postoperative skin infection or septic arthritis, however, three patients did have a pin tract infection that was effectively managed. Conclusion: The technique is suitable for the treatment of complex proximal tibia fractures when there is substantial comminution at the fracture site as well as soft tissue damage (Schatzker VI).
引用
收藏
页码:451 / 459
页数:9
相关论文
共 50 条
  • [31] Bilateral Gastrocnemius Muscle Flap for Bilateral Defects of Knee Joint in Schatzker Type V & VI Proximal Tibial Condyle Fractures
    Manas, Raj Kumar
    Chinta, Kavya
    PLASTIC SURGERY, 2024, 32 (01) : 148 - 152
  • [32] Capsuloligamentotaxis and definitive fixation by an ankle-spanning Ilizarov fixator in high-energy pilon fractures
    Kapoor, S. K.
    Kataria, H.
    Patra, S. R.
    Boruah, T.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08): : 1100 - 1106
  • [33] Open proximal & distal fractures of tibia treated with Naseer Awais External Fixator with T-clamp
    Makhdoom, Asadullah
    Das Maheshwari, Lachman
    Laghari, Muhammad Ayoub
    Tahir, Syed Muhammad
    Ali, Syed Muhammad
    Siddiqui, Khaleeque Ahmed
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2015, 65 (07) : 727 - 732
  • [34] Treatment of Infected Nonunion of Fracture of the Proximal Third of Tibia Using Ilizarov Ring Fixator: A Case Series
    Kulkarni, Madhura Sujay
    Kulkarni, Milind
    Kulkarni, Ruta
    JOURNAL OF LIMB LENGTHENING & RECONSTRUCTION, 2024, 10 (01) : 16 - 21
  • [35] HIGH-ENERGY TIBIAL INJURIES - THE PEDESTRIAN TIBIA
    BURGESS, AR
    POKA, A
    EBRAHEIM, NA
    BRUMBACK, RJ
    LOEB, P
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1986, 26 (07): : 670 - 670
  • [36] Retrospective clinical outcomes in the definitive treatment of high-energy tibial diaphyseal fractures using hexapod external fixator versus monolateral external fixator
    Liu, Yanshi
    Liu, Kai
    Cai, Feiyu
    Zhang, Xingpeng
    Li, Hong
    Zhang, Tao
    Ma, Chuang
    Yusufu, Aihemaitijiang
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [37] Treament of Tibial Plateau Schatzker Type VI Fractures with the Ilizarov Technique Using Ring External Fixators Across the Knee: A Retrospective Review
    Ranatunga, I. R.
    Thirumal, M.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2010, 4 (02) : 34 - 39
  • [38] Imaging Review of Pelvic Ring Fractures and Its Complications in High-Energy Trauma
    Leone, Edoardo
    Garipoli, Andrea
    Ripani, Umberto
    Lanzetti, Riccardo Maria
    Spoliti, Marco
    Creta, Domenico
    Giannace, Carolina
    Galluzzo, Antonio
    Trinci, Margherita
    Galluzzo, Michele
    DIAGNOSTICS, 2022, 12 (02)
  • [39] Retrospective clinical outcomes in the definitive treatment of high-energy tibial diaphyseal fractures using hexapod external fixator versus monolateral external fixator
    Yanshi Liu
    Kai Liu
    Feiyu Cai
    Xingpeng Zhang
    Hong Li
    Tao Zhang
    Chuang Ma
    Aihemaitijiang Yusufu
    BMC Musculoskeletal Disorders, 23
  • [40] UNREAMED INTERLOCKING NAIL VERSUS EXTERNAL FIXATOR FOR OPEN TYPE-III TIBIA FRACTURES
    TU, YK
    LIN, CH
    SU, JI
    HSU, DT
    CHEN, RJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 39 (02): : 361 - 367