Result of Ring Fixator in High-energy Schatzker Type VI Fractures of Proximal Tibia

被引:2
|
作者
Khanzada, Aftab Alam [1 ]
Joyo, Muhammad Rafique [2 ]
Javed, Muhammad Imran [3 ]
Ahmed, Nizam [4 ]
Keerio, Niaz Hussain [5 ]
Shah, Ghazanfar Ali [6 ]
Noor, Syed Shahid [7 ]
机构
[1] Indus Med Coll Tando Muhammad Khan, Tando Muhammad Khan, Pakistan
[2] Heerabad Hosp, Bone Care Trauma Ctr, Hyderabad, Pakistan
[3] Ruth Pfau Fazaia Med Coll, Karachi, Pakistan
[4] Liaquat Univ Med & Hlth Sci, Jamshoro, Pakistan
[5] Muhammad Med Coll & Hosp, Mirpurkhas, Pakistan
[6] Dow Univ Med & Hlth Sci, SMBBIT, Karachi, Pakistan
[7] Liaquat Natl Hosp & Med Coll, Karachi, Pakistan
关键词
external fixator; tibial plateau; schatzker VI; Ilizarov; fractures; WIRE EXTERNAL FIXATION; PLATEAU FRACTURES; INTERNAL-FIXATION; CLASSIFICATION; MANAGEMENT; REDUCTION;
D O I
10.9734/JPRI/2021/v33i43B32574
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Significant articular depression, separation of both condyles, diaphyseal comminution and dissociation, and loss of soft-tissue envelope integrity are all associated with high-energy proximal tibia fractures (Schatzker VI). Over the past 50 years, there has been a lot of research on plating problems in these complicated fractures. For the care of these complex injuries, Ilizarov devised a new method (ring fixator). Aim of the Study: To examine the outcomes of patients who received a ring fixator for the treatment of high-energy proximal tibia fractures (Schatzker VI). Materials and Methods: Fourteen patients (mean age 36) were treated with the Ilizarov fixator and transfixion wires for high-energy fractures of the proximal tibia (Schatzker VI). Nine of the patients had open fractures, and five of them had significant soft tissue damage. They were all tracked for an average of 19.4 months. The result was analyzed using the criteria set by Honkonen & Jarvinen (1992). Results: Thirteen fractures healed in an average of 14.6 weeks, with one taking six months. Twelve patients recovered complete extension, while eight others regained more than 110 degrees of flexion. All of the patients knees were stable, except one who had a minor varus deformity. Nine patients walked normally, while four had a little limp. Except for one, all of the knees exhibited an articular step-off of less than 4 mm and normal axial alignment. Six knees were found to be outstanding, five to be decent, and three to be fair. There were no instances of postoperative skin infection or septic arthritis, however, three patients did have a pin tract infection that was effectively managed. Conclusion: The technique is suitable for the treatment of complex proximal tibia fractures when there is substantial comminution at the fracture site as well as soft tissue damage (Schatzker VI).
引用
收藏
页码:451 / 459
页数:9
相关论文
共 50 条
  • [21] Outcome of Schatzker type V and VI tibial plateau fractures
    Tul B. Pun
    Vignesh P. Krishnamoorthy
    Pradeep M. Poonnoose
    Anil T. Oommen
    Ravi J. Korula
    Indian Journal of Orthopaedics, 2014, 48 : 35 - 41
  • [22] Minimally Invasive Plating of High-Energy Metaphyseal Distal Tibia Fractures
    Collinge, Cory
    Kuper, Mark
    Larson, Kirk
    Protzman, Robert
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (06) : 355 - 361
  • [23] TREATMENT OF THE PROXIMAL METAPHYSEAL AND EPIPHYSEAL TIBIA FRACTURES WITH THE LIZAROVS FIXATOR (ABOUT 4 CASES)
    MAINARD, D
    REYNIER, A
    DELAGOUTTE, JP
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1990, 76 (05): : 336 - 341
  • [24] High-Energy Proximal Humerus Fractures in Geriatric Patients: A Review
    Walters, Jordan M.
    Ahmadi, Shahryar
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2020, 11
  • [25] Management of high-energy tibial shaft fractures using the hexapod circular external fixator
    Yanshi Liu
    Jialin Liu
    Maimaiaili Yushan
    Zhenhui Liu
    Tao Zhang
    He Ma
    Chuang Ma
    Aihemaitijiang Yusufu
    BMC Surgery, 21
  • [26] Management of high-energy tibial shaft fractures using the hexapod circular external fixator
    Liu, Yanshi
    Liu, Jialin
    Yushan, Maimaiaili
    Liu, Zhenhui
    Zhang, Tao
    Ma, He
    Ma, Chuang
    Yusufu, Aihemaitijiang
    BMC SURGERY, 2021, 21 (01)
  • [27] Minimally Invasive Medial Plate Osteosynthesis of High-Energy Pediatric Tibia Fractures
    Murphy, Michael
    Killen, Cameron
    Lynch, Kyle
    Cohen, Joseph
    Summers, Hobie
    Stover, Michael
    Lack, William
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (08) : E272 - E281
  • [28] High-energy open tibial fractures in children TREATMENT WITH A PROGRAMMABLE CIRCULAR EXTERNAL FIXATOR
    Monsell, F. P.
    Howells, N. R.
    Lawniczak, D.
    Jeffcote, B.
    Mitchell, S. R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 989 - 993
  • [29] Treatment of Schatzker Type II-VI Tibial Plateau Fractures by Means of Syndesmotaxis Using an Ilizarov External Fixator and Postoperative CT Evaluation
    Papadakis, Stamatios A.
    Pallis, Dimitrios
    Ampadiotaki, Margarita-Michaela
    Gourtzelidis, Georgios
    Kateros, Konstantinos
    Macheras, George
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (01)
  • [30] Complications in the management of closed high-energy proximal tibial plateau fractures
    Khatri, Kavin
    Sharma, Vijay
    Goyal, Darsh
    Farooque, Kamran
    CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (06) : 342 - 347