Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy

被引:29
|
作者
Gao, Liugang [1 ,2 ]
Xie, Kai [1 ,2 ]
Wu, Xiaojin [3 ]
Lu, Zhengda [1 ,2 ,4 ]
Li, Chunying [1 ,2 ]
Sun, Jiawei [1 ,2 ]
Lin, Tao [1 ,2 ]
Sui, Jianfeng [1 ,2 ]
Ni, Xinye [1 ,2 ]
机构
[1] Nanjing Med Univ, Peoples Hosp Changzhou 2, Dept Radiotherapy, Changzhou 213003, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Ctr Med Phys, Changzhou 213003, Jiangsu, Peoples R China
[3] Xuzhou 1 Peoples Hosp, Oncol Dept, Xuzhou 221000, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Sch Biomed Engn & Informat, Nanjing 213000, Peoples R China
关键词
Synthetic CT; Low-dose CBCT; Attention-guided GAN; Unpaired; Adaptive radiotherapy; SCATTER CORRECTION; RADIATION; FEASIBILITY;
D O I
10.1186/s13014-021-01928-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To develop high-quality synthetic CT (sCT) generation method from low-dose cone-beam CT (CBCT) images by using attention-guided generative adversarial networks (AGGAN) and apply these images to dose calculations in radiotherapy. Methods The CBCT/planning CT images of 170 patients undergoing thoracic radiotherapy were used for training and testing. The CBCT images were scanned under a fast protocol with 50% less clinical projection frames compared with standard chest M20 protocol. Training with aligned paired images was performed using conditional adversarial networks (so-called pix2pix), and training with unpaired images was carried out with cycle-consistent adversarial networks (cycleGAN) and AGGAN, through which sCT images were generated. The image quality and Hounsfield unit (HU) value of the sCT images generated by the three neural networks were compared. The treatment plan was designed on CT and copied to sCT images to calculated dose distribution. Results The image quality of sCT images by all the three methods are significantly improved compared with original CBCT images. The AGGAN achieves the best image quality in the testing patients with the smallest mean absolute error (MAE, 43.5 +/- 6.69), largest structural similarity (SSIM, 93.7 +/- 3.88) and peak signal-to-noise ratio (PSNR, 29.5 +/- 2.36). The sCT images generated by all the three methods showed superior dose calculation accuracy with higher gamma passing rates compared with original CBCT image. The AGGAN offered the highest gamma passing rates (91.4 +/- 3.26) under the strictest criteria of 1 mm/1% compared with other methods. In the phantom study, the sCT images generated by AGGAN demonstrated the best image quality and the highest dose calculation accuracy. Conclusions High-quality sCT images were generated from low-dose thoracic CBCT images by using the proposed AGGAN through unpaired CBCT and CT images. The dose distribution could be calculated accurately based on sCT images in radiotherapy.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Image Quality and Tumor Shape Correction in Sparse Projection Cone-Beam CT Using Conditional Generative Adversarial Networks
    Kamiyama, Sae
    Usui, Keisuke
    Suga, Kenta
    Adachi, Hiroto
    Arita, Akihiro
    Sakamoto, Hajime
    Kyogoku, Shinsuke
    Daida, Hiroyuki
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2025, 45 (01) : 138 - 146
  • [32] A more effective CT synthesizer using transformers for cone-beam CT-guided adaptive radiotherapy
    Chen, Xinyuan
    Liu, Yuxiang
    Yang, Bining
    Zhu, Ji
    Yuan, Siqi
    Xie, Xuejie
    Liu, Yueping
    Dai, Jianrong
    Men, Kuo
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [33] Low-dose CT denoising using a Progressive Wasserstein generative adversarial network
    Wang, Guan
    Hu, Xueli
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 135 (135)
  • [34] A Preliminary Study on Optimal Dose-Allocation Parameters for Low-Dose Cone-Beam CT
    Zhang, Z.
    Han, X.
    Pearson, E.
    Bian, J.
    Sidky, E.
    Pelizzari, C.
    Pan, X.
    MEDICAL PHYSICS, 2011, 38 (06) : 3443 - +
  • [35] Dose calculation using megavoltage cone-beam CT
    Morin, Olivier
    Chen, Josephine
    Aubin, Michele
    Gillis, Amy
    Aubry, Jean-Francois
    Bose, Supratik
    Chen, Hong
    Descovich, Martina
    Xia, Ping
    Pouliot, Jean
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1201 - 1210
  • [36] ENHANCE GENERATIVE ADVERSARIAL NETWORKS BY WAVELET TRANSFORM TO DENOISE LOW-DOSE CT IMAGES
    Su, Wanqi
    Qu, Yili
    Deng, Chufu
    Wang, Ying
    Zheng, Fudan
    Chen, Zhiguang
    2020 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2020, : 350 - 354
  • [37] Self-supervised denoising of projection data for low-dose cone-beam CT
    Choi, Kihwan
    Kim, Seung Hyoung
    Kim, Sungwon
    MEDICAL PHYSICS, 2023, 50 (10) : 6319 - 6333
  • [38] Low-dose and Scatter-free Cone-beam CT imaging: a preliminary study
    Dong, Xue
    Jia, Xun
    Niu, Tianye
    Zhu, Lei
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [39] A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer
    Posiewnik, M.
    Piotrowski, T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 13 - 21
  • [40] Selection of lung cancer patients for adaptive radiotherapy using cone-beam CT imaging
    Hattu, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S177 - S177