Self-supervised denoising of projection data for low-dose cone-beam CT

被引:7
|
作者
Choi, Kihwan [1 ]
Kim, Seung Hyoung [2 ]
Kim, Sungwon [2 ]
机构
[1] Korea Inst Sci & Technol, Bion Res Ctr, Seoul, South Korea
[2] Yonsei Univ, Dept Radiol, Coll Med, Seoul, South Korea
关键词
cone-beam CT; dose reduction; model fusion; projection-domain denoising; self-supervised learning; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; NOISE-REDUCTION; QUALITY; NETWORK; REPAIR;
D O I
10.1002/mp.16421
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Convolutional neural networks (CNNs) have shown promising results in image denoising tasks. While most existing CNN-based methods depend on supervised learning by directly mapping noisy inputs to clean targets, high-quality references are often unavailable for interventional radiology such as cone-beam computed tomography (CBCT). Purpose: In this paper, we propose a novel self-supervised learning method that reduces noise in projections acquired by ordinary CBCT scans. Methods: With a network that partially blinds input, we are able to train the denoising model by mapping the partially blinded projections to the original projections. Additionally, we incorporate noise-to-noise learning into the self -supervised learning by mapping the adjacent projections to the original projections. With standard image reconstruction methods such as FDK-type algorithms, we can reconstruct high-quality CBCT images from the projections denoised by our projection-domain denoising method. Results: In the head phantom study, we measure peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) values of the proposed method along with the other denoising methods and uncorrected low-dose CBCT data for a quantitative comparison both in projection and image domains. The PSNR and SSIM values of our self -supervised denoising approach are 27.08 and 0.839, whereas those of uncorrected CBCT images are 15.68 and 0.103, respectively. In the retrospective study, we assess the quality of interventional patient CBCT images to evaluate the projection-domain and image-domain denoising methods. Both qualitative and quantitative results indicate that our approach can effectively produce high-quality CBCT images with low-dose projections in the absence of duplicate clean or noisy references. Conclusions: Our self -supervised learning strategy is capable of restoring anatomical information while efficiently removing noise in CBCT projection data.
引用
收藏
页码:6319 / 6333
页数:15
相关论文
共 50 条
  • [1] Self-supervised Projection Denoising for Low-Dose Cone-Beam CT
    Choi, Kihwan
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3459 - 3462
  • [2] Low-Dose Cone-Beam Dedicated Breast CT: Self-Supervised Denoising From Single Image
    Fu, Z.
    Tseng, H.
    Karellas, A.
    Vedantham, S.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E636 - E636
  • [3] Self-Supervised Deep Learning for Low-Dose CT Image Denoising
    Bai, T.
    Nguyen, D.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E658 - E658
  • [4] Self-Supervised Dual-Domain Network for Low-dose CT Denoising
    Niu, Chuang
    Li, Mengzhou
    Guo, Xiaodong
    Wang, Ge
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [5] Strided Self-Supervised Low-Dose CT Denoising for Lung Nodule Classification
    Lei, Yiming
    Zhang, Junping
    Shan, Hongming
    [J]. PHENOMICS, 2021, 1 (06): : 257 - 268
  • [6] Strided Self-Supervised Low-Dose CT Denoising for Lung Nodule Classification
    Yiming Lei
    Junping Zhang
    Hongming Shan
    [J]. Phenomics, 2021, 1 : 257 - 268
  • [7] ON THE BENEFIT OF DUAL-DOMAIN DENOISING IN A SELF-SUPERVISED LOW-DOSE CT SETTING
    Wagner, Fabian
    Thies, Mareike
    Pfaff, Laura
    Aust, Oliver
    Pechmann, Sabrina
    Weidner, Daniela
    Maul, Noah
    Rohleder, Maximilian
    Gu, Mingxuan
    Utz, Jonas
    Denzinger, Felix
    Maier, Andreas
    [J]. 2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [8] SELF-SUPERVISED TRAINING FOR LOW-DOSE CT RECONSTRUCTION
    Unal, Mehmet Ozan
    Ertas, Metin
    Yildirim, Isa
    [J]. 2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 69 - 72
  • [9] Short-Scan Cone-Beam Dedicated Breast CT: Self-Supervised Denoising From Single Image
    Fu, Z.
    Tseng, H.
    Karellas, A.
    Vedantham, S.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E629 - E630
  • [10] Preliminary Investigation of Dose Allocation in Low-dose Cone-beam CT
    Han, Xiao
    Pearson, Erik
    Bian, Junguo
    Cho, Seungryong
    Sidky, Emil Y.
    Pelizzari, Charles A.
    Pan, Xiaochuan
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2051 - 2054