Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system

被引:22
|
作者
Bai, Hongyu [1 ]
Zhu, Jie [1 ]
Chen, Xiangjie [1 ]
Chu, Junze [1 ]
Cui, Yuanlong [2 ]
Yan, Yuying [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Derby, Dept Mech Engn & Built Environm, Derby DE22 3AW, England
关键词
Complete dehumidification system; Liquid desiccant; Numerical modelling; Cooling capacity; COP; AIR DEHUMIDIFICATION; MASS-TRANSFER; HEAT; FLOW; COMFORT; DESIGN; MODEL;
D O I
10.1016/j.apenergy.2019.114082
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A complete membrane-based liquid desiccant dehumidification system is investigated under the steady operating condition, which mainly consists of a dehumidifier, a regenerator, three heat exchangers, a cold and a hot water supply units. A finite difference mathematical model is developed for the complete system to investigate the system dehumidification performance and energy requirement, and validated by experimental data. The dehumidification performance is evaluated by the system sensible and latent effectiveness and moisture flux rate, while its energy performance is assessed by the total cooling capacity and coefficient of performance. It is found that the number of heat transfer units in the dehumidifier side and solution to air mass flow rate ratio have the most considerable impact on the system performance, while the number of heat transfer units in the regenerator side and solution inlet concentration in the dehumidifier have comparatively weak influences. The system sensible and latent effectiveness can be improved by increasing the dehumidifier side number of heat transfer units before reaching its critical value of 6. However, the amount of moisture being absorbed, total cooling capacity and coefficient of performance decrease with the dehumidifier side number of heat transfer units at the low air flow rate. The critical value of solution to air mass flow rate ratio varies with number of heat transfer units, and it is preferable to keep the flow rate ratio at or below its critical value as further increasing solution flow rate would reduce the system coefficient of performance.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Energy-saving in a liquid desiccant dehumidification system with a semipermeable-membrane-assisted dual sump
    Lee, Soo-Jin
    Jeong, Jae-Weon
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 37
  • [42] Thermodynamic performance assessment of vacuum membrane-based dehumidification and air carrying energy radiant air-conditioning system (VMD-ACERS)
    Chun, Liang
    Gong, Guangcai
    Fang, Xi
    Peng, Pei
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2021, 34 : 217 - 227
  • [43] Performance assessment of integrated liquid desiccant dehumidification with vapor-compression system for energy-efficient air conditioning applications
    Bhowmik, Mrinal
    Rath, Siddharth
    Varela, Richard Jayson
    Muthukumar, P.
    Anandalakshmi, R.
    Saito, Kiyoshi
    APPLIED THERMAL ENGINEERING, 2022, 216
  • [44] Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system
    Yang, Yu
    Yan, Junwei
    Zhou, Xuan
    Xiao, Liehui
    Huang, Si-Min
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 (131) : 87 - 100
  • [45] Thermodynamic performance assessment of vacuum membrane-based dehumidification and air carrying energy radiant air-conditioning system(VMD-ACERS)
    Liang Chun
    Guangcai Gong
    Xi Fang
    Pei Peng
    ChineseJournalofChemicalEngineering, 2021, 34 (06) : 217 - 227
  • [46] Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant
    Liu, Xiaoli
    Qu, Ming
    Liu, Xiaobing
    Wang, Lingshi
    Warner, Joseph
    Gao, Zhiming
    APPLIED THERMAL ENGINEERING, 2020, 181
  • [47] Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant
    Liu, Xiaoli
    Qu, Ming
    Liu, Xiaobing
    Wang, Lingshi
    Warner, Joseph
    APPLIED THERMAL ENGINEERING, 2020, 175
  • [48] Mass Transfer Correlation for Tubular Membrane-Based Liquid Desiccant Air-Conditioning System
    Cihan, Ertugrul
    Kavasogullari, Baris
    Demir, Hasan
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (02) : 519 - 529
  • [49] Mass Transfer Correlation for Tubular Membrane-Based Liquid Desiccant Air-Conditioning System
    Ertuğrul Cihan
    Barış Kavasoğulları
    Hasan Demir
    Arabian Journal for Science and Engineering, 2020, 45 : 519 - 529
  • [50] Performance assessment of sustainable energy based novel technique for multistage reciprocating liquid dehumidification system
    Salins, Sampath Suranjan
    Reddy, S. V. Kota
    Kumar, Shiva
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 179