Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

被引:8
|
作者
Liu, Xiaoli [1 ]
Qu, Ming [1 ]
Liu, Xiaobing [2 ]
Wang, Lingshi [2 ]
Warner, Joseph [2 ]
Gao, Zhiming [2 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, Civil Engn Bldg,550 Stadium Mall Dr, W Lafayette, IN 47907 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN USA
关键词
Numerical modeling; Membrane; Ionic liquid desiccant; Air dehumidifier; MASS EXCHANGER; RELATIVE-HUMIDITY; HEAT; FLOW; SYSTEM; CONTACTOR; SINGLE;
D O I
10.1016/j.applthermaleng.2020.115754
中图分类号
O414.1 [热力学];
学科分类号
摘要
Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented in this paper. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. The results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant
    Liu, Xiaoli
    Qu, Ming
    Liu, Xiaobing
    Wang, Lingshi
    Warner, Joseph
    [J]. APPLIED THERMAL ENGINEERING, 2020, 175
  • [2] Numerical Modeling and Performance Analysis of a Membrane-based Air Dehumidifier Using Ionic Liquid Desiccant (vol 175, 115395, 2020)
    Liu, Xiaoli
    Qu, Ming
    Liu, Xiaobing
    Wang, Lingshi
    Warner, Joseph
    Gao, Zhiming
    [J]. APPLIED THERMAL ENGINEERING, 2020, 181
  • [3] A Novel Heat and Mass Transfer Model for Membrane-based Ionic Liquid Desiccant Air Dehumidifier
    Liu, Xiaoli
    Qu, Ming
    Liu, Xiaobing
    Warner, Joseph
    [J]. ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 392 - 400
  • [4] Experiments on a novel membrane-based liquid desiccant dehumidifier for hybrid air conditioner
    Gurubalan, A.
    Maiya, M. P.
    Tiwari, Shaligram
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 271 - 282
  • [5] Performance optimization of polymeric porous membrane-based liquid desiccant air dehumidifier used in air conditioning system
    Ali Mohammad Jafarpour
    Farivar Fazelpour
    Seyyed Abbas Mousavi
    [J]. International Journal of Energy and Environmental Engineering, 2020, 11 : 55 - 71
  • [6] Performance optimization of polymeric porous membrane-based liquid desiccant air dehumidifier used in air conditioning system
    Jafarpour, Ali Mohammad
    Fazelpour, Farivar
    Mousavi, Seyyed Abbas
    [J]. INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2020, 11 (01) : 55 - 71
  • [7] Experimental study of a membrane-based liquid desiccant dehumidifier based on internal air temperature variation
    Chu, Junze
    Zhu, Jie
    Bai, Hongyu
    Cui, Yuanlong
    [J]. APPLIED THERMAL ENGINEERING, 2019, 159
  • [8] Performance characteristics assessment of hollow fiber membrane-based liquid desiccant dehumidifier for drying application
    Tejes, P. K. S.
    Priyadarshi, Gaurav
    Naik, B. Kiran
    [J]. APPLIED THERMAL ENGINEERING, 2023, 218
  • [9] Experimental and numerical analysis of a three-fluid membrane-based ionic liquid desiccant absorber
    Bhagwat, Rohit
    Schmid, Michael
    Moghaddam, Saeed
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 183
  • [10] Analytical Modeling and Performance Study of a Cross Flow Air Dehumidifier Using Liquid Desiccant
    Bassuoni, M. M.
    [J]. MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1205 - 1213