Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

被引:9
|
作者
Liu, Xiaoli [1 ]
Qu, Ming [1 ]
Liu, Xiaobing [2 ]
Wang, Lingshi [2 ]
Warner, Joseph [2 ]
Gao, Zhiming [2 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, Civil Engn Bldg,550 Stadium Mall Dr, W Lafayette, IN 47907 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN USA
关键词
Numerical modeling; Membrane; Ionic liquid desiccant; Air dehumidifier; MASS EXCHANGER; RELATIVE-HUMIDITY; HEAT; FLOW; SYSTEM; CONTACTOR; SINGLE;
D O I
10.1016/j.applthermaleng.2020.115754
中图分类号
O414.1 [热力学];
学科分类号
摘要
Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented in this paper. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. The results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers
    Ahmadi, Behnam
    Ahmadi, Masoud
    Nawaz, Kashif
    Momen, Ayyoub M.
    Bigham, Sajjad
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 132 : 21 - 29
  • [22] Heat and mass transfer in an adjacent internally-cooled membrane-based liquid desiccant dehumidifier (AIMLDD)
    Yang, Yu
    Yang, Minlin
    Huang, Weihao
    Huang, Si-Min
    Ye, Wei-Biao
    Hong, Yuxiang
    Qin, Frank G. F.
    Shao, Youyuan
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 3990 - 3997
  • [23] Conjugate heat and mass transfer in an internally-cooled membrane-based liquid desiccant dehumidifier (IMLDD)
    Huang, Si-Min
    Zhong, Zhanrong
    Yang, Minlin
    JOURNAL OF MEMBRANE SCIENCE, 2016, 508 : 73 - 83
  • [24] Experimental investigation and performance analysis of a spray-type ionic liquid desiccant dehumidifier
    Liang, Jyun-De
    Kao, Chia-Lin
    Chen, Chih-Hao
    Ho, Hong-Yi
    Huang, Chih-Hsueh
    Chen, Sih-Li
    APPLIED THERMAL ENGINEERING, 2024, 254
  • [25] Experimental Investigation on a Novel Air Dehumidifier Using Liquid Desiccant
    Qiu, G. Q.
    Riffat, S. B.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2010, 7 (02) : 174 - 180
  • [26] Performance study of heat and mass transfer in a counterflow liquid to air membrane-based parallel-plate dehumidifier
    Taous, Abir
    Ben Nasr, Kaouther
    Guizani, Amen Allah
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (09) : 2216 - 2225
  • [27] An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant
    Wang, Lingshi
    Liu, Xiaobing
    Qu, Ming
    Liu, Xiaoli
    Bahar, Bamdad
    ENERGY AND BUILDINGS, 2022, 254
  • [28] A novel method to evaluate the performance of liquid desiccant air dehumidifier system
    Bakhtiar, Agung
    Rokhman, Fatkhur
    Choi, Kwang Hwan
    ENERGY AND BUILDINGS, 2012, 44 : 39 - 44
  • [29] A simulation study of the effects of membrane structure parameters on dehumidification performance of membrane-based liquid dehumidifier
    Niu, Runping
    Yang, Xuan
    Kong, Xiangchen
    Cui, Chunqi
    Li, Yifan
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [30] PERFORMANCE ANALYSIS ON THE INTERNALLY COOLED DEHUMIDIFIER USING TWO LIQUID DESICCANT SOLUTIONS
    Koronaki, I. P.
    Christodoulaki, R. I.
    Papaefthimiou, V. D.
    Rogdakis, E. D.
    PROCEEDINGS OF THE ASME 11TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2012, VOL 2, 2012, : 627 - 638