Natural Ventilation with Dynamic Facades

被引:0
|
作者
Takemasa, Yuichi [1 ]
Hiraoka, Masaya [2 ]
Katoh, Masahiro [1 ]
Miura, Katsuhiro [1 ]
Kasai, Shinji [2 ]
Oya, Tsuyoshi [2 ]
机构
[1] Kajima Tech Res Inst, Kajima, Japan
[2] Kajima Corp, Kajima Design, Kajima, Japan
关键词
natural ventilation; office building; large space; double-skin facade; cross ventilation; stack ventilation; stack effect; field measurement; CFD analysis; Japanese examples;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the light of global environmental problems, it is vital for buildings to conserve energy and make use of natural energies. Natural ventilation is one important method for achieving this. In houses, natural ventilation is a very attractive way to control the indoor environment. Compared to this, mid- to high-rise buildings include many closed spaces where windows cannot be opened and internal heat is trapped inside, which increases the cooling load. Based on this situation, consciousness of environmentally friendly buildings and utilization of natural energy becomes high. Introducing fresh outside air directly into the indoors can create a more comfortable environment for building occupants, in addition to realizing energy savings. Natural ventilation is commonly implemented in buildings such as homes, but its application in mid- to high-rise buildings has been hampered by many issues such as ensuring building performance and determining control methods. Therefore, design techniques for natural ventilation are strongly required. Design techniques for natural ventilation have been developed and applied to many buildings in Japan. This paper describes the outline of the design technique developed by the authors and introduces some examples of natural ventilation with dynamic facades in non-residential buildings in Japan.
引用
收藏
页码:287 / 298
页数:12
相关论文
共 50 条
  • [21] Dynamic modelling of a wind catcher/tower turret for natural ventilation
    Elmualim, Abbas Ali
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2006, 27 (03): : 165 - 182
  • [22] Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling
    Yoon, Nari
    Norford, Leslie
    Malkawi, Ali
    Samuelson, Holly
    Piette, Mary Ann
    BUILDING AND ENVIRONMENT, 2020, 180
  • [23] Natural Ventilation: Optimizing Window Opening Size for CO2 Concentration Control and Thermal Comfort on Nonwindward Facades
    Hsu, Hsieh-Chih
    Chang, Chin-Wei
    Chen, Chien-Chih
    Pan, Chen-Yu
    INDOOR AIR, 2024, 2024
  • [24] Dynamic Thermal Performance of the BIPV Facades
    Rahiminejad, Mohammad
    Paris, Alexandre L. M.
    Khovalyg, Dolaana
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 1, 2021, 127 : 170 - 178
  • [25] Dynamic performance of cable net facades
    Feng, Ruo-qiang
    Zhang, Lin-lin
    Wu, Yue
    Shen, Shi-zhao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (12) : 2217 - 2227
  • [26] Use of Coanda nozzles for double glazed facades forced ventilation
    Valentin, D.
    Guardo, A.
    Egusquiza, E.
    Valero, C.
    Alavedra, P.
    ENERGY AND BUILDINGS, 2013, 62 : 605 - 614
  • [27] Deterioration and repair possibilities of natural stone facades
    Landensivu, J.
    PROTECTION OF HISTORICAL BUILDINGS - PROHITECH 09, VOL 1 AND 2, 2009, : 1239 - 1244
  • [28] Guidelines for inspection of natural stone building facades
    Brom, AP
    BUILDING FACADE MAINTENANCE, REPAIR, AND INSPECTION, 2004, 1444 : 301 - 315
  • [29] Simplified direct forcing approach for dynamic modeling of building natural ventilation
    Wu, Wentao
    Han, Jung Min
    Malkawi, Ali
    Building and Environment, 2021, 188
  • [30] Evaluation of Natural Ventilation and Cooling Systems using Dynamic Simulation Methods
    Khan, Naghman
    Su, Yuehong
    Hopper, Nick
    Riffat, Saffa
    INTERNATIONAL JOURNAL OF VENTILATION, 2011, 10 (02) : 133 - 146