Fans are the most widespread system used to implement forced convection ventilation for double glazed facades (DGF). However, the implementation of fans in a facade require an electrical supply for the motors, solid supports for the fans, and the installation has to meet fire safety regulations required by local laws. These facts, added to the need of a regular maintenance program for the fans and the possibility of noise and vibration generated by the moving parts of these equipment, might increase the final cost of the facade and reduce the comfort inside the building. In this paper the feasibility of using nozzles for DGF ventilation is evaluated. The nozzles selected for this study are based on the Coanda effect. For this investigation, a CFD model was used to simulate a Coanda nozzle. The modeled nozzle was simulated for different flow rate conditions and velocity and pressure fields obtained in the nozzle outlet were imposed as an inlet boundary condition in an upper crossed lateral ventilation model for a DGF. Results obtained for heat flux, and reductions in solar gain loads for different operating conditions were obtained and compared against previous results for vertical and horizontal DGF ventilation in a similar geometry. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:605 / 614
页数:10
相关论文
共 50 条
  • [1] CFD assessment of the performance of lateral ventilation in Double Glazed Facades in Mediterranean climates
    Guardo, A.
    Coussirat, M.
    Valero, C.
    Egusquiza, E.
    Alavedra, P.
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2539 - 2547
  • [2] Double skin glazed facades in sunny Mediterranean climates
    Flores Larsen, Silvana
    Rengifo, Luis
    Filippin, Celina
    ENERGY AND BUILDINGS, 2015, 102 : 18 - 31
  • [3] THE USE OF STRUCTURAL GLASS IN SHAPING GLAZED FACADES
    Jozwik, Anna
    TEKA KOMISJI URBANISTYKI I ARCHITEKTURY, 2023, 51 : 359 - 384
  • [4] Influence of glass properties on the performance of double-glazed facades
    Pérez-Grande, I
    Meseguer, J
    Alonso, G
    APPLIED THERMAL ENGINEERING, 2005, 25 (17-18) : 3163 - 3175
  • [5] Performance and influence of numerical sub-models on the CFD simulation of free and forced convection in double-glazed ventilated facades
    Coussirat, M.
    Guardo, A.
    Jou, E.
    Egusquiza, E.
    Cuerva, E.
    Alavedra, P.
    ENERGY AND BUILDINGS, 2008, 40 (10) : 1781 - 1789
  • [6] Integration of double facades and ventilation systems in buildings
    Di Maio, F
    van Paassen, AHC
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1225 - 1232
  • [7] Experimental Analysis of Double and Triple Glazed Facades with Different Shading Devices in Qatar
    Al Touma, Albert
    Ouahrani, Djamel
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE SUSTAINABLE AND RENEWABLE ENERGY ENGINEERING (ICSREE 2017), 2017, : 38 - 41
  • [8] The Sound Insulation of Double Facades with Openings for Natural Ventilation
    Bajraktari, Egzon
    Lechleitner, Josef
    Mahdavi, Ardeshir
    BUILDING ACOUSTICS, 2015, 22 (3-4) : 163 - 176
  • [9] Pre-dimensioning of ventilation openings in double facades
    Friedrich, Matthias
    Schweers, Klaus
    Wellershoff, Frank
    BAUPHYSIK, 2022, 44 (04) : 187 - 202
  • [10] Estimating the sound insulation of double facades with openings for natural ventilation
    Bajraktari, Egzon
    Lechleitner, Josef
    Mandavi, Ardeshir
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 140 - 145