Aortic dissection: Is the false lumen really important?

被引:1
|
作者
Shatila, Wassim [1 ,2 ]
Krajcer, Zvonimir [1 ,2 ,3 ]
机构
[1] Texas Heart Inst, Dept Cardiol, Houston, TX 77025 USA
[2] Baylor Coll Med, Dept Cardiol, Houston, TX 77030 USA
[3] CHI St Lukes Hlth Baylor St Lukes Med Ctr, Div Cardiol, Dept Med, Houston, TX USA
关键词
aortic dissection; outcomes; percutaneous interventions; thrombosis;
D O I
10.1002/ccd.27882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Key Points Aortic dissection is associated with a high mortality rate and has been increasingly treated with endovascular therapy. False lumen (FL) patency has been shown to be associated with worse outcomes. FL interventions that incorporate the FLIRT (FL intervention to promote remodeling and thrombosis) concept have been associated with improved aortic remodeling that may confer favorable long-term outcomes.
引用
收藏
页码:741 / 742
页数:2
相关论文
共 50 条
  • [31] Proximal false lumen thrombosis is associated with low false lumen pressure and fewer complications in type B aortic dissection
    Parker, Louis P.
    Reutersberg, Benedikt
    Syed, Maaz B. J.
    Munshi, Bijit
    Richards, Samantha
    Kelsey, Lachlan J.
    Sakalihasan, Natzi
    Eckstein, Hans-Henning
    Norman, Paul E.
    Doyle, Barry J.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (04) : 1181 - +
  • [32] Methods and Outcomes of Endovascular False Lumen Embolization for Thoracic Aortic Dissection
    Li, Hai -Lei
    Chan, Yiu Che
    Jia, He-Yue
    Cheng, Stephan W.
    ANNALS OF VASCULAR SURGERY, 2022, 85 : 371 - 382
  • [33] Chronic thoracoabdominal aortic dissection: endovascular options to obliterate the false lumen
    Vargo, Patrick R.
    Maigrot, Jean-Luc
    Roselli, Eric E.
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (06) : 778 - 783
  • [34] Transesophageal echocardiography for assessment of acute aortic dissection with a thrombosed false lumen
    Mitani, M
    Ichimura, T
    Natori, H
    Kaneko, M
    RADIOLOGY, 1996, 201 : 276 - 276
  • [35] Outcomes of stent-graft treatment of false lumen in aortic dissection
    Kato, M
    Matsuda, T
    Kaneko, M
    Kuratani, T
    Mizushima, T
    Seo, Y
    Uchida, H
    Kichikawa, K
    Maeda, M
    Ohnishi, K
    CIRCULATION, 1998, 98 (19) : II305 - II311
  • [36] Aortic False Lumen Thrombosis Induction by Embolotherapy (AFTER) Following Endovascular Repair of Aortic Dissection
    Hofferberth, Sophie C.
    Nixon, Ian K.
    Mossop, Peter J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (04) : 538 - 545
  • [37] Thoracic Endovascular Aortic Repair After Iatrogenic Aortic Dissection and False Lumen Stent Grafting
    Schrimpf, Claudia
    Teebken, Omke E.
    Wilhelmi, Mathias
    ANNALS OF THORACIC SURGERY, 2015, 99 (04): : 1447 - 1449
  • [38] Thoracic Aortic Stent Migration to False Lumen in Aortic Dissection Detected by Intraoperative Transesophageal Echocardiography
    Inoue, Hiroshi
    Morita, Mariko
    Ota, Takahisa
    Ito, Jun
    Uchida, Hiroaki
    ANESTHESIA AND ANALGESIA, 2016, 122 (04): : 963 - 966
  • [39] AORTIC COBWEBS - AN ANATOMIC MARKER IDENTIFYING THE FALSE LUMEN IN AORTIC DISSECTION - IMAGING AND PATHOLOGICAL CORRELATION
    WILLIAMS, DM
    JOSHI, A
    DAKE, MD
    DEEB, GM
    MILLER, DC
    ABRAMS, GD
    RADIOLOGY, 1994, 190 (01) : 167 - 174
  • [40] Outer Media Thickness at False Lumen and Secondary Aortic Dilatation After Acute Aortic Dissection
    Kinoshita, Takeshi
    Asai, Tohru
    Suzuki, Tomoaki
    ANNALS OF THORACIC SURGERY, 2022, 114 (05): : 1646 - 1654