Thoracic Aortic Stent Migration to False Lumen in Aortic Dissection Detected by Intraoperative Transesophageal Echocardiography

被引:2
|
作者
Inoue, Hiroshi [1 ]
Morita, Mariko [1 ]
Ota, Takahisa [2 ]
Ito, Jun [1 ]
Uchida, Hiroaki [1 ]
机构
[1] Sendai Kousei Hosp, Dept Anesthesia, Sendai, Miyagi 9800873, Japan
[2] Tohoku Univ Hosp, Dept Anesthesiol, Sendai, Miyagi, Japan
来源
ANESTHESIA AND ANALGESIA | 2016年 / 122卷 / 04期
关键词
D O I
10.1213/ANE.0000000000001132
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
[No abstract available]
引用
收藏
页码:963 / 966
页数:4
相关论文
共 50 条
  • [1] Successful repair of intraoperative aortic dissection detected by transesophageal echocardiography
    Varghese, D
    Riedel, BJCJ
    Fletcher, SN
    Al-Momatten, MI
    Khaghani, A
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 953 - 955
  • [2] Transesophageal echocardiography for assessment of acute aortic dissection with a thrombosed false lumen
    Mitani, M
    Ichimura, T
    Natori, H
    Kaneko, M
    RADIOLOGY, 1996, 201 : 276 - 276
  • [3] Use of Intraoperative Transesophageal Echocardiography and Epiaortic Ultrasound to Diagnose False Lumen Enlargement of Chronic Aortic Dissection
    Honda, Jun
    Hakozaki, Takahiro
    Hasegawa, Takayuki
    Obara, Shinju
    Inoue, Satoki
    ANNALS OF CARDIAC ANAESTHESIA, 2023, 26 (03) : 333 - 335
  • [4] Aortic dissection after cardiopulmonary bypass detected by intraoperative transesophageal echocardiography
    Anderson, C
    Joyce, FS
    Tingleff, J
    Arendrup, H
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (09) : 1227 - 1228
  • [5] Thoracic Endovascular Aortic Repair After Iatrogenic Aortic Dissection and False Lumen Stent Grafting
    Schrimpf, Claudia
    Teebken, Omke E.
    Wilhelmi, Mathias
    ANNALS OF THORACIC SURGERY, 2015, 99 (04): : 1447 - 1449
  • [6] Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography
    Mohamed Eissa
    Asadollah Mir-Ghassemi
    Sudhir Nagpal
    Hesham F. Talab
    JA Clinical Reports, 8
  • [7] Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography
    Eissa, Mohamed
    Mir-Ghassemi, Asadollah
    Nagpal, Sudhir
    Talab, Hesham F.
    JA CLINICAL REPORTS, 2022, 8 (01)
  • [8] Utility of intraoperative transesophageal echocardiography during endovascular stent-graft repair of acute thoracic aortic dissection
    Gonzalez-Fajardo, JA
    Gutierrez, V
    San Roman, JA
    Serrador, A
    Arreba, E
    del Rio, L
    Martin, M
    Carrera, S
    Vaquero, C
    ANNALS OF VASCULAR SURGERY, 2002, 16 (03) : 297 - 303
  • [9] Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection
    Kamman, Arnoud V.
    Williams, David M.
    Patel, Himanshu J.
    ANNALS OF VASCULAR SURGERY, 2017, 42 : 303.e11 - 303.e14
  • [10] Intraoperative Evaluation of Visceral Arteries by Transesophageal Echocardiography in Stanford B Thoracic Aortic Dissection
    Tampo, Akihito
    Kunisawa, Takayuki
    Kurosawa, Atsushi
    Takahata, Osamu
    Iwasaki, Hiroshi
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 589 - 590