Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans

被引:0
|
作者
Wang, Lin [1 ,2 ,3 ,4 ]
Zhang, Jianping [1 ,2 ,3 ,4 ,5 ]
Huang, Miaoyun [1 ,3 ,4 ]
Xu, Benhua [1 ,2 ,3 ,4 ,5 ]
Li, Xiaobo [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fujian Med Univ, Dept Radiat Oncol, Union Hosp, Fuzhou, Peoples R China
[2] Fujian Med Univ, Coll Med Technol & Engn, Dept Med Imaging Technol, Fuzhou, Peoples R China
[3] Fujian Med Univ, Fujian Key Lab Intelligent Imaging & Precis Radio, Fuzhou, Peoples R China
[4] Clin Res Ctr Radiol & Radiotherapy Fujian Prov Di, Fuzhou, Peoples R China
[5] Fujian Med Univ, Union Clin Med Coll, Fuzhou, Peoples R China
来源
DOSE-RESPONSE | 2022年 / 20卷 / 03期
关键词
radiobiological assessment; anisotropic analytical algorithm and acuros external beam; gamma passing rate; composition of the structures; esophageal carcinoma; DOSE-TO-MEDIUM; MONTE-CARLO; DOSIMETRIC VALIDATION; REPORTING MODES; XB ALGORITHM; WATER; AAA; DIFFERENCE; IMPACT; HEAD;
D O I
10.1177/15593258221105678
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: The present study aimed to investigate the dose differences and radiobiological assessment between Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) with its 2 calculation models, namely, dose-to-water (AXB-Dw) and dose-to-medium (AXB-Dm), on esophageal carcinoma radiotherapy treatment plans. Materials and methods: The AXB-Dw and AXB-Dm plans were generated by recalculating the initial 66 AAA plans using the AXB algorithm with the same monitor units and beam parameters as those in the original plan. The dosimetric and radiobiological assessment parameters were calculated for the planning target volume (PTV) and organs at risk (OARs). The gamma agreement for the PTV and the correlation between it and the volume of the air cavity and bone among the different algorithms were compared simultaneously. The dose discrepancy between the theoretical calculation and treatment planning system (TPS) when switching from AXB-Dm to AXB-Dw was analyzed according to the composition of the structures. Results: The PTV dose of AXB-Dm plans was significantly smaller than that of the AAA and AXB-Dw plans (P < .05), except for D-2. The difference values for AAA vs AXB-Dm ( increment D-x,D-(AAA-AXB,D-Dm)) and AXB-Dw vs AXB-Dm ( increment D-x,D-(AXB,D-Dw-AXB,D-Dm)) were 1.94% [1.27%, 2.64%] and 1.95% [1.56%, 2.27%], respectively. For the spinal cord and heart, there were obvious differences between the AAA vs AXB-Dm (spinal cord: 1.15%, heart: 2.89%) and AXB-Dw vs AXB-Dm (spinal cord: 1.88%, heart: 3.25%) plans. For the lung, the differences between AAA vs AXB-Dm and AAA vs AXB-Dw were significantly larger than those of AXB-Dm vs AXB-Dw. Compared to the case of AAA and AXB-Dw, the decrease in biologically effective dose (BED10, alpha beta=10 ) of AXB-Dm due to dose non-uniformity exceeded 6.5%, even for a small sigma. The average values of equivalent uniform dose in the AAA, AXB-Dw, and AXB-Dm plans were 52.03 +/-.39 Gy, 52.24 +/- .81 Gy, and 51.13 +/- .47 Gy, respectively. The tumor control probability (TCP) results for PTV in the AAA, AXB-Dw, and AXB-Dm plans were 62.29 +/- 1.57%, 62.82 +/- 1.69%, and 58.68 +/- 1.88%, respectively. With the 2%/2 mm and 3%/3 mm acceptance criteria, the mean values of Delta gamma(AXB-Dw)(AAA), Delta gamma(AXB-Dm)(AAA), and Delta gamma(AXB-Dw)(AXB-Dm) were 87.24, 63.3, and 64.81% vs 97.86, 91.77, and 89.25%, respectively. The dose discrepancy between the theoretical calculation and TPS when switching from AXB-Dm to AXB-Dw was approximately 1.63%. Conclusions: The AAA and AXB-Dw algorithms overestimated the radiobiological parameters when the tumor particularly consisted of nonuniform tissues. A relatively small dose difference could cause a significant reduction in the corresponding TCP. Dose distribution algorithms should be carefully chosen by physicists and oncologists to improve tumor control, as well as to optimize OARs protection.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A comparison of Monte Carlo, anisotropic analytical algorithm (AAA) and Acuros XB algorithms in assessing dosimetric perturbations during enhanced dynamic wedged radiotherapy deliveries in heterogeneous media
    Zaman, Ashfaq
    Kakakhel, Muhammad Basim
    Hussain, Amjad
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 75 - 81
  • [32] Errors detected during physics plan review for external beam radiotherapy treatment plans
    Siebert, F.
    Hirt, M.
    Delaperriere, M.
    Dunst, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1844 - S1846
  • [33] Treatment of carcinoma of the female urethra by primary external beam and interstitial radiotherapy
    Reyna, A
    Wajsman, Z
    Zlotecki, RA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S431 - S431
  • [34] Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans
    Murugesan Kathirvel
    Shanmuga Subramanian
    Alessandro Clivio
    Gandhi Arun
    Antonella Fogliata
    Giorgia Nicolini
    Vellaiyan Subramani
    Shanmugam Thirumalai Swamy
    Eugenio Vanetti
    Luca Cozzi
    Radiation Oncology, 8
  • [35] Comparison of radiobiological parameters for 90Y radionuclide therapy (RNT) and external beam radiotherapy (EBRT) in vitro
    Yaser H. Gholami
    Kathy P. Willowson
    Nicholas J. Forwood
    Rozelle Harvie
    Nicholas Hardcastle
    Regina Bromley
    HyunJu Ryu
    Samuel Yuen
    Viive M. Howell
    Zdenka Kuncic
    Dale L. Bailey
    EJNMMI Physics, 5
  • [36] Comparison of radiobiological parameters for 90Y radionuclide therapy (RNT) and external beam radiotherapy (EBRT) in vitro
    Gholami, Yaser H.
    Willowson, Kathy P.
    Forwood, Nicholas J.
    Harvie, Rozelle
    Hardcastle, Nicholas
    Bromley, Regina
    Ryu, HyunJu
    Yuen, Samuel
    Howell, Viive M.
    Kuncic, Zdenka
    Bailey, Dale L.
    EJNMMI PHYSICS, 2018, 5
  • [37] Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans
    Kathirvel, Murugesan
    Subramanian, Shanmuga
    Clivio, Alessandro
    Arun, Gandhi
    Fogliata, Antonella
    Nicolini, Giorgia
    Subramani, Vellaiyan
    Swamy, Shanmugam Thirumalai
    Vanetti, Eugenio
    Cozzi, Luca
    RADIATION ONCOLOGY, 2013, 8
  • [38] Comparison of stereotactic body radiotherapy and conventional external beam radiotherapy in renal cell carcinoma.
    Tinkle, Christopher L.
    Shiao, Stephen Lawrence
    Weinberg, Vivian K.
    Lin, Amy M.
    Gottschalk, Alexander R.
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (07)
  • [39] Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size
    Huang, Baotian
    Wu, Lili
    Lin, Peixian
    Chen, Chuangzhen
    RADIATION ONCOLOGY, 2015, 10
  • [40] Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size
    Baotian Huang
    Lili Wu
    Peixian Lin
    Chuangzhen Chen
    Radiation Oncology, 10