Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans

被引:0
|
作者
Wang, Lin [1 ,2 ,3 ,4 ]
Zhang, Jianping [1 ,2 ,3 ,4 ,5 ]
Huang, Miaoyun [1 ,3 ,4 ]
Xu, Benhua [1 ,2 ,3 ,4 ,5 ]
Li, Xiaobo [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fujian Med Univ, Dept Radiat Oncol, Union Hosp, Fuzhou, Peoples R China
[2] Fujian Med Univ, Coll Med Technol & Engn, Dept Med Imaging Technol, Fuzhou, Peoples R China
[3] Fujian Med Univ, Fujian Key Lab Intelligent Imaging & Precis Radio, Fuzhou, Peoples R China
[4] Clin Res Ctr Radiol & Radiotherapy Fujian Prov Di, Fuzhou, Peoples R China
[5] Fujian Med Univ, Union Clin Med Coll, Fuzhou, Peoples R China
来源
DOSE-RESPONSE | 2022年 / 20卷 / 03期
关键词
radiobiological assessment; anisotropic analytical algorithm and acuros external beam; gamma passing rate; composition of the structures; esophageal carcinoma; DOSE-TO-MEDIUM; MONTE-CARLO; DOSIMETRIC VALIDATION; REPORTING MODES; XB ALGORITHM; WATER; AAA; DIFFERENCE; IMPACT; HEAD;
D O I
10.1177/15593258221105678
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: The present study aimed to investigate the dose differences and radiobiological assessment between Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) with its 2 calculation models, namely, dose-to-water (AXB-Dw) and dose-to-medium (AXB-Dm), on esophageal carcinoma radiotherapy treatment plans. Materials and methods: The AXB-Dw and AXB-Dm plans were generated by recalculating the initial 66 AAA plans using the AXB algorithm with the same monitor units and beam parameters as those in the original plan. The dosimetric and radiobiological assessment parameters were calculated for the planning target volume (PTV) and organs at risk (OARs). The gamma agreement for the PTV and the correlation between it and the volume of the air cavity and bone among the different algorithms were compared simultaneously. The dose discrepancy between the theoretical calculation and treatment planning system (TPS) when switching from AXB-Dm to AXB-Dw was analyzed according to the composition of the structures. Results: The PTV dose of AXB-Dm plans was significantly smaller than that of the AAA and AXB-Dw plans (P < .05), except for D-2. The difference values for AAA vs AXB-Dm ( increment D-x,D-(AAA-AXB,D-Dm)) and AXB-Dw vs AXB-Dm ( increment D-x,D-(AXB,D-Dw-AXB,D-Dm)) were 1.94% [1.27%, 2.64%] and 1.95% [1.56%, 2.27%], respectively. For the spinal cord and heart, there were obvious differences between the AAA vs AXB-Dm (spinal cord: 1.15%, heart: 2.89%) and AXB-Dw vs AXB-Dm (spinal cord: 1.88%, heart: 3.25%) plans. For the lung, the differences between AAA vs AXB-Dm and AAA vs AXB-Dw were significantly larger than those of AXB-Dm vs AXB-Dw. Compared to the case of AAA and AXB-Dw, the decrease in biologically effective dose (BED10, alpha beta=10 ) of AXB-Dm due to dose non-uniformity exceeded 6.5%, even for a small sigma. The average values of equivalent uniform dose in the AAA, AXB-Dw, and AXB-Dm plans were 52.03 +/-.39 Gy, 52.24 +/- .81 Gy, and 51.13 +/- .47 Gy, respectively. The tumor control probability (TCP) results for PTV in the AAA, AXB-Dw, and AXB-Dm plans were 62.29 +/- 1.57%, 62.82 +/- 1.69%, and 58.68 +/- 1.88%, respectively. With the 2%/2 mm and 3%/3 mm acceptance criteria, the mean values of Delta gamma(AXB-Dw)(AAA), Delta gamma(AXB-Dm)(AAA), and Delta gamma(AXB-Dw)(AXB-Dm) were 87.24, 63.3, and 64.81% vs 97.86, 91.77, and 89.25%, respectively. The dose discrepancy between the theoretical calculation and TPS when switching from AXB-Dm to AXB-Dw was approximately 1.63%. Conclusions: The AAA and AXB-Dw algorithms overestimated the radiobiological parameters when the tumor particularly consisted of nonuniform tissues. A relatively small dose difference could cause a significant reduction in the corresponding TCP. Dose distribution algorithms should be carefully chosen by physicists and oncologists to improve tumor control, as well as to optimize OARs protection.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Comparison of Treatment Plans in External Beam Radiotherapy
    Nunez, L.
    Herrero, M. A.
    Alfonso, J. C. L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] The radiobiological effect of using Acuros XB vs anisotropic analytical algorithm on hepatocellular carcinoma stereotactic body radiation therapy
    Cheung, Michael L. M.
    Kan, Monica W. K.
    Yeung, Vanessa T. Y.
    Poon, Darren M. C.
    Kam, Michael K. M.
    Lee, Louis K. Y.
    Chan, Anthony T. C.
    MEDICAL DOSIMETRY, 2022, 47 (02) : 161 - 165
  • [3] Dosimetric and radiobiological comparison in different dose calculation grid sizes between Acuros XB and anisotropic analytical algorithm for prostate VMAT
    Kim, Kyeong-Hyeon
    Chung, Jin-Beom
    Suh, Tae Suk
    Kang, Sang-Won
    Kang, Seong-Hee
    Eom, Keun-Yong
    Song, Changhoon
    Kim, In-Ah
    Kim, Jae-Sung
    PLOS ONE, 2018, 13 (11):
  • [4] Comparison of Acuros and Anisotropic Analytical Algorithm for dose calculations in VMAT treatments
    Ambroa Rey, E. M.
    Rodriguez Meijide, P.
    Perez Fernandez, M.
    Lopez Sanchez, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S725 - S726
  • [5] COMBINED INTRACAVITARY AND EXTERNAL BEAM RADIOTHERAPY IN THE TREATMENT OF ESOPHAGEAL-CARCINOMA
    CLAGUE, MB
    DAWES, PJDK
    GUT, 1989, 30 (10) : A1494 - A1494
  • [6] Comparison of Dose Calculation Algorithms Between Acuros XB and Anisotropic Analytical Algorithm in RapidArc Plans for High-Grade Glioma
    Takizawa, T.
    Tanabe, S.
    Utsunomiya, S.
    Kushima, N.
    Ohta, A.
    Saito, H.
    Nakano, T.
    Abe, E.
    Kaidu, M.
    Aoyama, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E301 - E302
  • [7] Clinical implications of Eclipse analytical anisotropic algorithm and Acuros XB algorithm for the treatment of lung cancer
    Krishna, Gangarapu
    Srinivas, Vuppu
    Reddy, Palreddy Yadagiri
    JOURNAL OF MEDICAL PHYSICS, 2016, 41 (04) : 219 - 223
  • [8] Dosimetric and Radiobiological Comparison of External Beam Radiotherapy Using Simultaneous Integrated Boost Technique for Esophageal Cancer in Different Location
    Wang, Lu
    Li, Chengqiang
    Meng, Xue
    Li, Chengming
    Sun, Xindong
    Shang, Dongping
    Pang, Linlin
    Li, Yixiao
    Lu, Jie
    Yu, Jinming
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [9] Dosimetric comparison of external beam radiotherapy treatment plans using VMAT optimization tools
    Gil Lopez, Carmen
    RADIOTHERAPY AND ONCOLOGY, 2024, 197 : S392 - S394
  • [10] Comparison of 3D conformal breast radiation treatment plans using the anisotropic analytical algorithm and pencil beam convolution algorithm
    Yoo, Sua
    Wu, Qiuwen
    O'Daniel, Jennifer
    Horton, Janet
    Yin, Fang-Fang
    RADIOTHERAPY AND ONCOLOGY, 2012, 103 (02) : 172 - 177