Design and validation of a CT-guided robotic system for lung cancer brachytherapy

被引:18
|
作者
Dou, Huaisu [1 ]
Jiang, Shan [1 ,2 ]
Yang, Zhiyong [1 ]
Sun, Luqing [1 ]
Ma, Xiaodong [1 ]
Huo, Bin [3 ]
机构
[1] Tianjin Univ, Sch Mech Engn, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Ctr Adv Mech & Robot, Tianjin 300350, Peoples R China
[3] Tianjin Med Univ, Dept Oncol, Hosp 2, Tianjin 300211, Peoples R China
基金
中国国家自然科学基金;
关键词
CT-guided; lung cancer brachytherapy; surgical robot; treatment planning; PUNCTURE ROBOT; ACCURACY; BIOPSIES; SAFETY;
D O I
10.1002/mp.12435
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Currently, lung brachytherapy in clinical setting is a complex procedure. Operation accuracy depends on accurate positioning of the template; however, it is difficult to guarantee the positioning accuracy manually. Application of robotic-assisted systems can simplify the procedure and improve the manual positioning accuracy. Therefore, a novel CT-guided robotic system was developed to assist the lung cancer brachytherapy. Methods: A four degree-of-freedom (DOF) robot, controlled by a lung brachytherapy treatment planning system (TPS) software, was designed and manufactured to assist the template positioning. Target position of the template can be obtained from the treatment plan, thus the robot is driven to the target position automatically. The robotic system was validated in both the laboratory and the CT environment. In laboratory environment, a 3D laser tracker and an inertial measurement unit (IMU) were used to measure the mechanical accuracy in air, which includes positioning accuracy and position repeatability. Working reliability was also validated in this procedure by observing the response reliability and calculating the position repeatability. Imaging artifacts and accuracy of the robot registration were validated in the CT environment by using an artificial phantom with fiducial markers. CT images were obtained and used to test the image artifact and calculate the registration accuracy. Phantom experiments were conducted to test the accuracy of needle insertion by using a transparent hydrogel phantom with a high imitation artificial phantom. Also, the efficiency was validated in this procedure by comparing time costs in manual positioning with robotic positioning under the same experimental conditions. Results: The robotic system achieved the positioning accuracy of 0.28 +/- 0.25 mm and the position repeatability of 0.09 +/- 0.11 mm. Experimental results showed that the robot was CT-compatible and responded reliably to the control commands. The mean registration accuracy of the robotic system was 0.49 +/- 0.29 mm. Phantom experiments indicated that the accuracy of needle insertion was 1.5 +/- 1.7 mm at a depth ranging from 30 to 80 mm. The time used to adjust the template to the target position was 12 min on average by robotic system automatically. An average of 30 min was saved compared with the manual positioning procedure in phantom experiments. Conclusions: This paper describes the design and experimental validation of a novel CT-guided robotic system for lung cancer brachytherapy. The robotic system was validated in a number of aspects which prove that it was capable of locating the template with clinically acceptable accuracy in the CT environment. All experimental results indicated that the system is reliable and ready to be applied to further studies on animals. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4828 / 4837
页数:10
相关论文
共 50 条
  • [1] CT-guided brachytherapy: complications
    Mohnike, K.
    Wolff, S.
    Peters, N.
    Seidensticker, M.
    Pech, M.
    Wybranski, C.
    Wieners, G.
    Gademann, G.
    Rieke, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 153 - 153
  • [2] CT-GUIDED AFTERLOADING BRACHYTHERAPY FOR ADVANCED CERVICAL CANCER
    Xue-lian, D.
    Sheng, X-G
    Jiang, T.
    Wang, C.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2014, 24 (08) : 44 - 44
  • [3] CT-guided interstitial brachytherapy of inoperable non-small cell lung cancer
    Wang, Zhong-Min
    Lu, Jian
    Liu, Tao
    Chen, Ke-Min
    Huang, Gang
    Liu, Fen-Ju
    LUNG CANCER, 2011, 74 (02) : 253 - 257
  • [4] CT-guided radiofrequency ablation for lung cancer
    Matsuoka, Toshiyuki
    Okuma, Tomohisa
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (02) : 71 - 78
  • [5] The benefits of CT-guided freehand interstitial brachytherapy for cervical cancer
    Yang, X.
    Li, Z.
    Fu, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S312 - S312
  • [6] CT-guided radiofrequency ablation for lung cancer
    Toshiyuki Matsuoka
    Tomohisa Okuma
    International Journal of Clinical Oncology, 2007, 12 : 71 - 78
  • [7] Modelling and analysis of a novel CT-guided puncture robot for lung brachytherapy
    Jiang, Shan
    Yuan, Wei
    Yang, Yunpeng
    Zhang, Daguang
    Liu, Ningbo
    Wang, Wei
    ADVANCED ROBOTICS, 2017, 31 (11) : 557 - 569
  • [8] Comparison of CT-guided and MR-guided HDR brachytherapy for prostate cancer
    Haverkamp, U
    Prümer, BA
    Krause, K
    Tschuschke, C
    Blumberg, J
    Benkel, P
    Fischedick, AR
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 118 - 119
  • [9] Lesion positioning method of a CT-guided surgical robotic system for minimally invasive percutaneous lung
    Zhang, Tie-Feng
    Fu, Zhuang
    Wang, Yao
    Shi, Wei-Yi
    Chen, Guang-Biao
    Fei, Jian
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (02):
  • [10] CT-guided hydrogel injection for brachytherapy in cervical cancer: A case report
    Wang, Yuxuan
    Zhang, Fuquan
    Hu, Ke
    Yu, Lang
    Zhang, Jie
    Luo, Chunli
    Yu, Lihua
    Yan, Junfang
    MEDICAL DOSIMETRY, 2024, 49 (04) : 353 - 358