Indoor air quality and energy performance of air-conditioned office buildings in Singapore

被引:41
|
作者
Sekhar, SC [1 ]
Tham, KW [1 ]
Cheong, KW [1 ]
机构
[1] Natl Univ Singapore, Dept Bldg, Singapore, Singapore
关键词
air-conditioned office building; building symptom index; field measurements; indoor air quality audit; indoor pollutant standard index; questionnaire analysis; tropical building;
D O I
10.1111/j.1600-0668.2003.00191.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An integrated indoor air quality (IAQ)-energy audit methodology has been developed in this study in Singapore, which provides a rigorous and systematic method of obtaining the status-quo assessment of an 'IAQ signature' in a building. The methodology entails a multi-disciplinary model in obtaining measured data pertaining to different dimensions within the built environment such as the physical, chemical, biological, ventilation, and occupant response characteristics. This paper describes the audit methodology and presents the findings from five air-conditioned office buildings in Singapore. The research has also led to the development of an indoor pollutant standard index (IPSI), which is discussed in this paper. Other performance indicators such as, the ventilation index and the energy index as well as the building symptom index (BSI) are also presented and discussed in the context of an integrated approach to IAQ and energy. Several correlation attempts were made on the various symptoms, indoor air acceptability, thermal comfort, BSI and IPSI, and while BSI values are found to correlate among them as well as with IAQ and THERMAL COMFORT acceptability, no such correlation was observed between BSI and IPSI. This would suggest that the occupants' perception of symptoms experienced as well as environmental acceptability is quite distinct from IAQ acceptability determined from empirical measurements of indoor pollutants, which reinforces the complex nature of IAQ issues.
引用
收藏
页码:315 / 331
页数:17
相关论文
共 50 条
  • [21] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [22] An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) : 1362 - 1367
  • [23] Impact of Window's Height on Energy Efficiency in Air-Conditioned Office Buildings
    Al-Ashwal, Najib Taher
    Hassan, Ahmad Sanusi
    [J]. ADVANCED SCIENCE LETTERS, 2017, 23 (11) : 11540 - 11544
  • [24] Energy use, indoor temperature and possible adaptation strategies for air-conditioned office buildings in face of global warming
    Guan, Lisa
    [J]. BUILDING AND ENVIRONMENT, 2012, 55 : 8 - 19
  • [25] INDOOR AIR QUALITY OF THE OFFICE BUILDINGS
    Senitkova, Ingrid
    Tomcik, Tomas
    [J]. CESB 10: CENTRAL EUROPE TOWARDS SUSTAINABLE BUILDING - FROM THEORY TO PRACTICE, 2010, : 517 - 520
  • [26] A global approach of indoor environment in an air-conditioned office room
    Rutman, E
    Inard, C
    Bailly, A
    Allard, F
    [J]. BUILDING AND ENVIRONMENT, 2005, 40 (01) : 29 - 37
  • [27] Implication of global warming on air-conditioned office buildings in Australia
    Guan, Lisa
    [J]. BUILDING RESEARCH AND INFORMATION, 2009, 37 (01): : 43 - 54
  • [28] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [29] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274
  • [30] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    [J]. INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +