Correlation between frequency doubling technology perimetry and temporal frequency characteristics in early glaucoma

被引:4
|
作者
Yu, JJH
Kiyosawa, M
Nemoto, N
Momose, K
Mori, H
Mochizuki, M
机构
[1] Taipei Ho Ping Hosp, Dept Ophthalmol, Taipei, Taiwan
[2] Kanagawa Inst Technol, Dept Informat Network Engn, Atsugi, Kanagawa, Japan
关键词
frequency doubling technology; pseudorandom stimulation; temporal frequency characteristics; VEP;
D O I
10.1023/A:1026270726285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the effectiveness of the temporal frequency characteristics (TFC) as an indicator of visual damage in patients with early open-angle glaucoma, TFC obtained from VEPs elicited by a pseudorandom binary sequence (PRBS) stimulus was compared with the frequency doubling technology (FDT) thresholds. Cross power spectrum between the PRBS stimulus as the input and the PRBS-VEPs as the output was calculated, and was used as the TFC. The normalized amplitude of the TFC at 2-4, 6-8, 10-12, 14-16, 18-20, 22-24, 26-28, and 30-32 Hz was calculated, and a coefficient of correlation between these values and the FDT thresholds was determined. The coefficients of correlation between the FDT thresholds and the TFC at 18-20 Hz for the central, 10degrees, 20degrees, and 30degrees were r = 0.03,0.31,0.2 1, and 0.16, respectively in non-glaucomatous normal control eyes, and those for the same regions of eyes with early glaucoma were r = 0.66, 0.46, 0.38, and 0.35, respectively. The coefficients of correlation between the FDT thresholds and TFC at temporal frequencies were relatively high at 18-20 and 26-32 Hz. The time required to obtain the PRBS-VEP data was approximately the same as that for the FDT thresholds. The strong correlation between the two tests indicates that the FDT values and the high temporal frequency segments of the TFC may be useful as a preliminary indicator of visual damage in patients with early open-angle glaucoma. In addition, the strong correlation suggests that there was a preferential damage to the magnocellular system in glaucomatous eyes.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 50 条
  • [31] Screening for glaucoma in India with the frequency doubling perimetry test
    Mansberger, SL
    Johnson, CA
    Cioffi, GA
    Krishnadas, R
    Srinivasan, M
    Balamurugan, V
    Kim, U
    Smith, SD
    Wilkins, JH
    Gritz, DC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U492 - U492
  • [32] Long-term fluctuation of standard automatic perimetry, pulsar Perimetry and frequency-doubling technology in early glaucoma diagnosis
    Gonzalez-Hernandez, M.
    de la Rosa, M. Gonzalez
    de la Vega, R. Rodriguez
    Hernandez-Vidal, A.
    OPHTHALMIC RESEARCH, 2007, 39 (06) : 338 - 343
  • [33] The relationship between frequency doubling technology (FDT) perimetry and useful field of view (UFOV) testing in glaucoma
    Spitze, Arielle R.
    Tatham, Andrew J.
    Rosen, Peter
    Zangwill, Linda M.
    Weinreb, Robert N.
    Sato, Michelle A.
    Boer, Erwin R.
    Medeiros, Felipe A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [34] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09): : 808 - 811
  • [35] Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage
    Soliman, MAE
    de Jong, LAMS
    Ismaeil, AA
    van den Berg, TJTP
    de Smet, MD
    OPHTHALMOLOGY, 2002, 109 (03) : 444 - 454
  • [36] Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma
    Boden, C
    Pascual, J
    Medeiros, FA
    Aihara, M
    Weinreb, RN
    Sample, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2433 - 2439
  • [37] THE ROLE OF FREQUENCY DOUBLING TECHNOLOGY PERIMETRY IN EARLY DETECTION OF DIABETIC RETINOPATHY
    Bradvica, Mario
    Biuk, Dubravka
    Bradvica, Ivanka Stenc
    Vinkovic, Maja
    Cerovski, Branimir
    Barac, Ivona
    ACTA CLINICA CROATICA, 2020, 59 (01) : 10 - 18
  • [38] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239
  • [39] Frequency doubling technology perimetry in normal children
    Quinn, Laurel M.
    Gardiner, Stuart K.
    Wheeler, David T.
    Newkirk, Michelle
    Johnson, Chris A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) : 983 - 989
  • [40] Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry
    Casson, R
    James, B
    Rubinstein, A
    Ali, H
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (03) : 360 - 362