Wide volume versus helical acquisition using 320-detector row computed tomography for computed tomography urography in adults

被引:7
|
作者
Roy, C. [1 ]
Quin, R. [1 ]
Labani, A. [1 ]
Leyendecker, P. [1 ]
Mertz, L. [2 ]
Ohana, M. [1 ]
机构
[1] Univ Hosp Strasbourg, Hop Civil 1, Dept Radiol B, Pl Hop, F-67091 Strasbourg, France
[2] Univ Hosp Strasbourg, Hop Civil 1, Med Phys Dept, Pl Hop,BP 426, F-67091 Strasbourg, France
关键词
Multidetector computed tomography (MDCT); Radiation dose reduction; Wide-volume CT; Helical CT optimization; TUBE CURRENT MODULATION; IMAGE QUALITY; CT SCANNER; CHEST CT; ANGIOGRAPHY; 320-MDCT; MODES;
D O I
10.1016/j.diii.2018.05.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the best collimation used in wide volume (WV) mode to cover the abdomen in computed tomography (CT) urography in terms of radiation dose and image quality. Materials and methods: This study was performed on a 320 x 0.5 mm detector row CT unit. The first part identified the lowest volume CT dose index (CTDIvol) by using the topograms data of 25 medium size patients (13 men and 12 women; mean age: 52+9 [SD] years; age range: 46-68 years) using different collimations on WV from 6 cm to 16 cm and the one of the helical mode for the same coverage length. The second part consisted of a clinical evaluation result including 45 medium size patients (32 men and 13 women; mean age: 68 +/- 14 [SD] years; age range: 45-72 years). The qualitative evaluation included several items based on a 5-point Likert scale. Results: The first part of the study indicated that a collimation of 10cm (200 x 0.5mm) in WV mode with 5 volumes had the lowest CTDIvol (2.78 +/- 0.35 mGy; range: 2.35-3.21 mGy) compared to helical mode (4.38 +/- 0.48 mGy, range: 3.75-4.95 mGy). In the second part, the mean radiation dose reduction by comparison with helical mode was 44.03% +/- 0.36% (P< 0.001) and 51.16% +/- 1.22% (P< 0.005) for CTDIvol and DLP, respectively. Conclusion: Wide volume mode of the abdomen can be performed with a significant radiation dose reduction with a collimation of 10cm (200 x 0.5 mm) and five volumes. (C) 2018 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:653 / 662
页数:10
相关论文
共 50 条
  • [41] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [42] Overranging and overbeaming measurement in area detector computed tomography: A method for simultaneous measurement in volume helical acquisition
    Urikura, Atsushi
    Hara, Takanori
    Yoshida, Tsukasa
    Nishimaru, Eiji
    Hoshino, Takashi
    Nakaya, Yoshihiro
    Endo, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (07): : 160 - 165
  • [43] OPTIMAL HEART RATE ADJUSTMENT CONTRIBUTES TO THE IMAGE QUALITY IN HALF SCAN RECONSTRUCTION WITH 320-DETECTOR ROW COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    Sera, Fusako
    Fujita, Masashi
    Watanabe, Tetsuya
    Awata, Masaki
    Iida, Osamu
    Okamoto, Shin
    Ishihara, Takayuki
    Dohi, Tomoharu
    Mishima, Tsuyoshi
    Sato, Kei
    Nanto, Kiyonori
    Mizukami, Yukika
    Uematsu, Masaaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E164 - E164
  • [44] IMPACT OF HEART RATE ON DIAGNOSTIC ACCURACY OF SECOND GENERATION 320-DETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    Nerlekar, Nitesh
    Nasis, Arthur
    Ko, Brian
    Leung, Michael
    Cameron, James
    Wong, Dennis
    Psaltis, Peter
    Meredith, Ian
    Troupis, John
    Seneviratne, Sujith
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1051 - A1051
  • [45] Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography
    Nerlekar, Nitesh
    Ko, Brian S.
    Nasis, Arthur
    Cameron, James D.
    Leung, Michael
    Brown, Adam J.
    Wong, Dennis T. L.
    Ngu, Philip J.
    Troupis, John M.
    Seneviratne, Sujith K.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2017, 7 (03) : 296 - 304
  • [46] Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method
    Hara, Takanori
    Urikura, Atsushi
    Ichikawa, Katsuhiro
    Hoshino, Takashi
    Nishimaru, Eiji
    Niwa, Shinji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 625 - 630
  • [47] The dynamics of deglutition during head rotation using dynamic 320-row area detector computed tomography
    Kochi, Kazutaka
    Sei, Hirofumi
    Tanabe, Yuki
    Yasuda, Kazunori
    Kido, Teruhito
    Yamada, Hiroyuki
    Taguchi, Aki
    Hato, Naohito
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (03): : 746 - 753
  • [48] Usefulness of 320-Row Area Detector Computed Tomography for the Diagnosis of Cystic Falx Meningioma
    Tabuchi, Sadaharu
    Nakajima, Sadao
    CASE REPORTS IN ONCOLOGY, 2013, 6 (02): : 362 - 366
  • [49] Evaluation of velopharyngeal closure by 4D imaging using 320-detector-row computed tomography
    Sakamoto, Yoshiaki
    Soga, Shigeyoshi
    Jinzaki, Masahiro
    Yamada, Yoshitake
    Ogata, Hisao
    Kishi, Kazuo
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (04): : 479 - 484
  • [50] Visualization of flow dynamics in the portal circulation using 320-detector-row computed tomography: a feasibility study
    Ken Kageyama
    Akira Yamamoto
    Atsushi Jogo
    Shinichiro Izuta
    Daisuke Himoto
    Akihiko Kakimi
    Etsuji Sohgawa
    Yukio Miki
    European Radiology Experimental, 5