Purpose: To evaluate the best collimation used in wide volume (WV) mode to cover the abdomen in computed tomography (CT) urography in terms of radiation dose and image quality. Materials and methods: This study was performed on a 320 x 0.5 mm detector row CT unit. The first part identified the lowest volume CT dose index (CTDIvol) by using the topograms data of 25 medium size patients (13 men and 12 women; mean age: 52+9 [SD] years; age range: 46-68 years) using different collimations on WV from 6 cm to 16 cm and the one of the helical mode for the same coverage length. The second part consisted of a clinical evaluation result including 45 medium size patients (32 men and 13 women; mean age: 68 +/- 14 [SD] years; age range: 45-72 years). The qualitative evaluation included several items based on a 5-point Likert scale. Results: The first part of the study indicated that a collimation of 10cm (200 x 0.5mm) in WV mode with 5 volumes had the lowest CTDIvol (2.78 +/- 0.35 mGy; range: 2.35-3.21 mGy) compared to helical mode (4.38 +/- 0.48 mGy, range: 3.75-4.95 mGy). In the second part, the mean radiation dose reduction by comparison with helical mode was 44.03% +/- 0.36% (P< 0.001) and 51.16% +/- 1.22% (P< 0.005) for CTDIvol and DLP, respectively. Conclusion: Wide volume mode of the abdomen can be performed with a significant radiation dose reduction with a collimation of 10cm (200 x 0.5 mm) and five volumes. (C) 2018 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:653 / 662
页数:10
相关论文
共 50 条
  • [21] Feasibility of tissue characterization of coronary plaques using 320-detector row computed tomography: comparison with integrated backscatter intravascular ultrasound
    Takahashi, Shigekiyo
    Kawasaki, Masanori
    Miyata, Shusaku
    Suzuki, Keita
    Yamaura, Makoto
    Ido, Takahisa
    Aoyama, Takuma
    Fujiwara, Hisayoshi
    Minatoguchi, Shinya
    HEART AND VESSELS, 2016, 31 (01) : 29 - 37
  • [22] Improved pelvicalyceal visualization with multidetector computed tomography urography; comparison with helical computed tomography
    V. Raptopoulos
    A. McNamara
    European Radiology, 2005, 15 : 1834 - 1840
  • [23] Evaluation of Pharyngoesophageal Segment Using 320-Row Area Detector Computed Tomography
    Wattanapan, Pattra
    Kagaya, Hitoshi
    Inamoto, Yoko
    Saitoh, Eiichi
    Shibata, Seiko
    Iida, Takatoshi
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (12): : 888 - 894
  • [24] Improved pelvicalyceal visualization with multidetector computed tomography urography; comparison with helical computed tomography
    Raptopoulos, V
    McNamara, A
    EUROPEAN RADIOLOGY, 2005, 15 (09) : 1834 - 1840
  • [25] Prediction of Cerebrovascular Reserve Capacity by Computed Tomography Perfusion Using 320-Row Computed Tomography
    Takahashi, Satoshi
    Tanizaki, Yoshio
    Kimura, Hiroaki
    Akaji, Kazunori
    Kano, Tadashige
    Suzuki, Kentaro
    Takayama, Youhei
    Kanzawa, Takao
    Shidoh, Satoka
    Nakazawa, Masaki
    Yoshida, Kazunari
    Mihara, Ban
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2015, 24 (05): : 939 - 945
  • [26] The Arterial System of the Fasciocutaneous Deltoid Flap Pedicle on 320-Detector Row Computed Tomography and Clinical Application in the Foot and Hand
    Ngoc-Huyen, Nguyen
    The-Hoang, Nguyen
    Lam, Khanh
    Quang-Vinh, Nguyen
    Staudenmaier, Rainer
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2025, 41 (01) : 77 - 84
  • [27] DIAGNOSTIC PERFORMANCE OF ADENOSINE STRESS COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING USING A 320-DETECTOR ROW CT IN PATIENTS WITH ATRIAL FIBRILLATION
    Takenaka, Masaki
    Sakakibara, Masaki
    Yamaguchi, Shogo
    Yokoi, Tsuyoshi
    Takeuchi, Shinsuke
    Twakawa, Naoki
    Kitagawa, Katsuhide
    Aoki, Soichiro
    Jinno, Yasushi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1110 - A1110
  • [28] Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
    Larsen, Linnea Hornbech
    Kofoed, Klaus Fuglsang
    Carstensen, Helle Gervig
    Mejdahl, Mads Rams
    Andersen, Mads Jonsson
    Kjaergaard, Jesper
    Nielsen, Olav Wendelboe
    Kober, Lars
    Mogelvang, Rasmus
    Hassager, Christian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01): : 165 - 173
  • [29] One beat scan with 320-detector computed tomography seems sufficient in clinical practice
    Imamura, T.
    Tanabe, K.
    Kishi, S.
    Tanimoto, S.
    Taniwaki, M.
    Otsuiki, S.
    Aoki, J.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2010, 31 : 133 - 133
  • [30] Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
    Yoneyama, Kihei
    Vavere, Andrea L.
    Cerci, Rodrigo
    Ahmed, Rukhsar
    Arai, Andrew E.
    Niinuma, Hiroyuki
    Rybicki, Frank J.
    Rochitte, Carlos E.
    Clouse, Melvin E.
    George, Richard T.
    Lima, Joao A. C.
    Arbab-Zadeh, Armin
    HEART INTERNATIONAL, 2012, 7 (02): : 51 - 56