Methods of Joint Stiffness Measurement Using a Manually Actuated Dynamometer

被引:0
|
作者
Kutilek, Patrik [1 ,2 ]
Volf, Petr [1 ]
Hybl, Jan [1 ]
Hejda, Jan [1 ]
Viteckova, Slavka [1 ]
Krivanek, Vaclav [2 ]
Doskocil, Radek [2 ]
Smrcka, Pavel [1 ]
机构
[1] Czech Tech Univ, Fac Biomed Engn, Sitna Sq, Kladno 3105, Czech Republic
[2] Univ Def, Fac Mil Technol, Kounicova 65, Brno, Czech Republic
关键词
Joint stiffness; Muscle myotonia; Dynamometer; Angular movement; Torque; Muscle; MUSCLE; RELIABILITY; SPASTICITY; TORQUE;
D O I
10.1007/978-3-030-29993-4_16
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The methods described provide for quantitative evaluation of skeletal muscles' passive resistance, also known as muscle stiffness, muscle myotonia or spasticity. They are employed in the quantitative evaluation of muscle groups responsible for angular movements in the elbow joint. The methods, along with the manually actuated dynamometer, represent an alternative to current evaluation methods which are considered inaccurate and subjective. The function of the electronic dynamometer subsystem is to measure angle and torque in the elbow joint. Stiffness can be evaluated by a graph of the torque moment and joint angle in mutual dependence. Since the curve of dependence demonstrates a relation between the torque moment and joint angle is composed of three parts (small, mean, and high angles), three polynomial equations for three regression lines must be calculated. This means that for three regression lines, three values of joint stiffness are obtained. Angular velocity of the rotational movement in a joint is the result of movement affected by a manually controlled lever of dynamometer. No statistically significant difference in joint stiffness values was identified, when comparing values for individual joint stiffness across three different groups of angular velocities; however, when the same comparison was made for small, mean and high angles, a statistically significant difference was identified for all three angular velocities used. The experiments with healthy subjects confirmed, that the torsional moment is dependent on the elbow angle, not on the velocity of the movement. Finding a correlation between a passive moment of force and kinematic angular parameters allows for the study of a complex movement in a joint.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [11] Identification of Hammerstein Systems Using Subspace Methods with Applications to Ankle Joint Stiffness
    Zhao, Yong
    Kearney, Robert E.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4367 - 4370
  • [12] Current methods for measurement of arterial stiffness
    Rajcinova, Mirela
    Zemanek, David
    Matera, Lukas
    Fabian, Vratislav
    COR ET VASA, 2023, 65 (03) : 525 - 528
  • [13] Automotive transmission efficiency measurement using a chassis dynamometer
    A. Irimescu
    L. Mihon
    G. Pãdure
    International Journal of Automotive Technology, 2011, 12 : 555 - 559
  • [14] Automotive transmission efficiency measurement using a chassis dynamometer
    Irimescu, A.
    Mihon, L.
    Padure, G.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2011, 12 (04) : 555 - 559
  • [15] Delay measurement of manually controlled intersection using GPS
    Nithya, S. (nithya@measiarch.net), 1600, (08):
  • [16] Quantitative measurement of spastic ankle joint stiffness using a manual device: A preliminary study
    Kobayashi, Toshiki
    Leung, Aaron K. L.
    Akazawa, Yasushi
    Tanaka, Masao
    Hutchins, Stephen W.
    JOURNAL OF BIOMECHANICS, 2010, 43 (09) : 1831 - 1834
  • [17] Characterisation of Antagonistically Actuated, Stiffness-Controllable Joint-Link Units for Cobots
    Gaozhang, Wenlong
    Shi, Jialei
    Li, Yue
    Stilli, Agostino
    Wurdemann, Helge
    2023 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, ICRA, 2023, : 655 - 661
  • [18] Limits of the manipulative-fixed method for measurement of shoulder joint horizontal adduction muscle strength using a handheld dynamometer
    Hirano, Masahiro
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (01) : 235 - 237
  • [19] MICROPROCESSOR-MEDIATED MEASUREMENT OF MCP JOINT STIFFNESS
    HOWE, A
    THOMPSON, D
    WRIGHT, V
    BRITISH JOURNAL OF RHEUMATOLOGY, 1985, 24 (02): : 220 - 221
  • [20] Measurement of Proprioception of the Knee in Hemiplegic Patients Using an Isokinetic Dynamometer
    Hwang, Ji Sun
    Lee, Dong Seok
    Cho, Yun Jeong
    Han, Na Mi
    Kim, Hyun Dong
    ANNALS OF REHABILITATION MEDICINE-ARM, 2010, 34 (01): : 27 - 33