Capacitor Current Feedback With Phase-Lead Compensator to Eliminate Resonant Frequency Forbidden Region for LCL-Type Grid-Connected Inverter in Weak Grid

被引:21
|
作者
Fang, Tianzhi [1 ]
Shen, Shuheng [1 ]
Zhang, Li [2 ]
Jin, Yinglin [3 ]
Huang, Chun [4 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Ctr More Elect Aircraft Power Syst, Coll Automat Engn, Nanjing 210016, Peoples R China
[2] Nanyang Technol Univ, Energy Res Inst, Singapore 637141, Singapore
[3] Texas Instruments Semicond Technol Shanghai Co Lt, Shanghai 200122, Peoples R China
[4] State Grid Meishan Power Supply Co China, Meishan 620000, Peoples R China
基金
中国国家自然科学基金;
关键词
Capacitor-current-feedback active damping; grid-connected inverter; LCL filter; phase-lead compensator; 2ND-HARMONIC CURRENT REDUCTION; TIME-DELAY COMPENSATION; DYNAMIC PERFORMANCE; CONTROLLER-DESIGN; DIGITAL-CONTROL; CONTROL SCHEMES; CONVERTER; STABILITY; FILTER; IMPROVEMENT;
D O I
10.1109/JESTPE.2021.3059024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Digital-controlled LCL-type grid-connected inverter, with capacitor-current-feedback active damping, is widely adopted in the mediate-to-high power application because of low output harmonics and high power quality. Owing to the digital control delay, however, the inverter robustness might be weakened against the grid-impedance variation. In this article, a simple phase-lead compensator is proposed to insert into the capacitor-current feedback-path for compensating the digital control delay. In doing so, the boundary frequency of the virtual-positive-resistance-region (VPRR) can be increased from one-sixth to almost one-fourth of the sampling frequency. In addition, the resonant frequency forbidden region for the LCL filter can be eliminated, such that the inverter robustness can be significantly improved against the grid-impedance variation. To ensure the system stability and attain a good control performance, a design procedure is further presented for the phase-lead compensator as well as the closed-loop parameters. Finally, an LCL-type grid-connected inverter is built and tested in the lab, and experimental results are presented to verify the effectiveness of the proposed control scheme and parameter design procedure.
引用
收藏
页码:5581 / 5596
页数:16
相关论文
共 50 条
  • [21] Stability Control of LCL-type Grid-connected Inverter Based on Capacitor Voltage Full Feedforward Under Weak Grid Condition
    Duan X.
    Li P.
    Zhao F.
    Chen S.
    Wang J.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (06): : 2140 - 2153
  • [22] Research on the stability caused by phase-locked loop for LCL-type grid-connected inverter in weak grid condition
    Wu, Heng
    Ruan, Xinbo
    Yang, Dongsheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (30): : 5259 - 5268
  • [23] Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Bao, Chenlei
    Li, Weiwei
    Wang, Xuehua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (07) : 3414 - 3427
  • [24] Investigation of the Sideband Effect for the LCL-type Grid-connected Inverter with High LCL Resonance Frequency
    Yang, Dongsheng
    Wang, Xiongfei
    Blaabjerg, Frede
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 5601 - 5606
  • [25] An Active Capacitor Converter for Improving Robustness of the LCL-Type Grid-Connected Inverter against Grid Impedance Variation
    Zhou, Qingfeng
    Wang, Xuehua
    Ruan, Xinbo
    Teng, Yu
    Liu, Fuxin
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 3608 - 3613
  • [26] A Hybrid Multiresonances Suppression Method for Nonsynchronous LCL-Type Grid-Connected Inverter Clusters Under Weak Grid
    Liu, Jiang
    Sun, Xiangdong
    Chen, Zechi
    Chi, Yongchao
    Song, Weizhang
    Zhu, Qun
    Wheeler, Patrick
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (05) : 5386 - 5399
  • [27] Systematic controller design for digitally controlled LCL-type grid-connected inverter with grid-current-feedback active damping
    Zhu, Donghai
    Zou, Xudong
    Zhao, Yingying
    Peng, Teng
    Zhou, Shiying
    Kang, Yong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 : 642 - 652
  • [28] Design and control of an LCL-type single-phase grid-connected inverter with inverter current feedback using the phase-delay method
    Evran, Fatih
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (06) : 4702 - 4714
  • [29] A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness
    Li, Shaojie
    Lin, Hua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) : 6462 - 6474
  • [30] Hybrid Active Damping Combining Capacitor Current Feedback and Point of Common Coupling Voltage Feedforward for LCL-Type Grid-Connected Inverter
    He, Yuying
    Wang, Xuehua
    Ruan, Xinbo
    Pan, Donghua
    Qin, Kuang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (02) : 2373 - 2383