Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter

被引:632
|
作者
Pan, Donghua [1 ]
Ruan, Xinbo [1 ,2 ]
Bao, Chenlei [1 ]
Li, Weiwei [1 ]
Wang, Xuehua [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech Ctr, Nanjing 210016, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; grid-connected inverter; grid impedance; LCL filter; open-loop unstable poles; POWER FILTER; DESIGN; PERFORMANCE; SYNCHRONIZATION; CONTROLLER; FREQUENCY; STABILITY;
D O I
10.1109/TPEL.2013.2279206
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the capacitor-current-feedback active damping for the digitally controlled LCL-type grid-connected inverter. It turns out that proportional feedback of the capacitor current is equivalent to virtual impedance connected in parallel with the filter capacitor due to the computation and pulse width modulation (PWM) delays. The LCL-filter resonance frequency is changed by this virtual impedance. If the actual resonance frequency is higher than one-sixth of the sampling frequency (f(s)/6), where the virtual impedance contains a negative resistor component, a pair of open-loop unstable poles will be generated. As a result, the LCL-type grid-connected inverter becomes much easier to be unstable if the resonance frequency is moved closer to f(s)/6 due to the variation of grid impedance. To address this issue, this paper proposes a capacitor-current-feedback active damping with reduced computation delay, which is achieved by shifting the capacitor current sampling instant towards the PWM reference update instant. With this method, the virtual impedance exhibits more like a resistor in a wider frequency range, and the open-loop unstable poles are removed; thus, high robustness against the grid-impedance variation is acquired. Experimental results from a 6-kW prototype confirm the theoretical expectations.
引用
收藏
页码:3414 / 3427
页数:14
相关论文
共 50 条
  • [1] Robust Capacitor-Current-Feedback Active Damping for the LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    Bao, Chenlei
    Li, Weiwei
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 728 - 735
  • [2] A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness
    Li, Shaojie
    Lin, Hua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) : 6462 - 6474
  • [3] Design of Injected Grid Current Regulator and Capacitor-Current-Feedback Active-Damping for LCL-Type Grid-Connected Inverter
    Bao, Chenlei
    Ruan, Xinbo
    Wang, Xuehua
    Li, Weiwei
    Pan, Donghua
    Weng, Kailei
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 579 - 586
  • [4] Capacitor-Current-Feedback With Improved Delay Compensation for LCL-Type Grid-Connected Inverter to Achieve High Robustness in Weak Grid
    Zhao, Tieying
    Li, Junran
    Gao, Ning
    IEEE ACCESS, 2022, 10 : 127956 - 127968
  • [5] Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method
    Li, Xiaoqiang
    Wu, Xiaojie
    Geng, Yiwen
    Yuan, Xibo
    Xia, Chenyang
    Zhang, Xue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5247 - 5259
  • [6] A Capacitor-Current-Feedback Active Damping Control Strategy With Phase Lead Compensation for LCL-Type Grid-Connected Inverter
    Zhang, Xieyan
    Xie, Yixuan
    Wu, Renwei
    IEEE ACCESS, 2024, 12 : 193663 - 193675
  • [7] Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping
    Bao, Chenlei
    Ruan, Xinbo
    Wang, Xuehua
    Li, Weiwei
    Pan, Donghua
    Weng, Kailei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1239 - 1253
  • [8] A capacitor-current real-time feedback active damping method for improving robustness of the LCL-type grid-connected inverter
    Pan, D. (pan_dh@hust.edu.cn), 1600, Chinese Society for Electrical Engineering (33):
  • [9] High Robustness Grid Current Feedback Active Damping Strategy for LCL-type Grid-connected Inverter in Weak Grid
    Dong G.
    Xu Z.
    Sun P.
    Li Q.
    Chen Y.
    Dianwang Jishu/Power System Technology, 2024, 48 (04): : 1672 - 1680
  • [10] Novel Capacitor Current Feedback Active Damping Strategy for Enhancing Robustness of LCL-type Grid-connected Inverters
    Cao Z.
    Xiao X.
    Ma J.
    Luo D.
    Yang X.
    Yu H.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (11): : 3781 - 3789