Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter

被引:632
|
作者
Pan, Donghua [1 ]
Ruan, Xinbo [1 ,2 ]
Bao, Chenlei [1 ]
Li, Weiwei [1 ]
Wang, Xuehua [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech Ctr, Nanjing 210016, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; grid-connected inverter; grid impedance; LCL filter; open-loop unstable poles; POWER FILTER; DESIGN; PERFORMANCE; SYNCHRONIZATION; CONTROLLER; FREQUENCY; STABILITY;
D O I
10.1109/TPEL.2013.2279206
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the capacitor-current-feedback active damping for the digitally controlled LCL-type grid-connected inverter. It turns out that proportional feedback of the capacitor current is equivalent to virtual impedance connected in parallel with the filter capacitor due to the computation and pulse width modulation (PWM) delays. The LCL-filter resonance frequency is changed by this virtual impedance. If the actual resonance frequency is higher than one-sixth of the sampling frequency (f(s)/6), where the virtual impedance contains a negative resistor component, a pair of open-loop unstable poles will be generated. As a result, the LCL-type grid-connected inverter becomes much easier to be unstable if the resonance frequency is moved closer to f(s)/6 due to the variation of grid impedance. To address this issue, this paper proposes a capacitor-current-feedback active damping with reduced computation delay, which is achieved by shifting the capacitor current sampling instant towards the PWM reference update instant. With this method, the virtual impedance exhibits more like a resistor in a wider frequency range, and the open-loop unstable poles are removed; thus, high robustness against the grid-impedance variation is acquired. Experimental results from a 6-kW prototype confirm the theoretical expectations.
引用
收藏
页码:3414 / 3427
页数:14
相关论文
共 50 条
  • [31] A Delay Compensation Method to Improve the Current Control Performance of the LCL-type Grid-connected Inverter
    Wang L.
    Sun P.
    Xue T.
    Li Q.
    Du X.
    Luo Q.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (19): : 6320 - 6329
  • [32] A Delay Compensation Method to Improve the Current Control Performance of the LCL-Type Grid-Connected Inverter
    Wang, Lin
    Sun, Pengju
    Wang, Jie
    Zhu, Kunlong
    Xue, Tongyu
    Zhang, Yuxin
    2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019), 2019, : 134 - 141
  • [33] Single-Feedback Based Inverter-Current-Controlled LCL-Type Grid-Connected Inverters with Capacitor-Current Active Damping: Robust Design and Single-Feedback Implementation
    Fan, Zeyang
    Yi, Hong
    Xu, Jian
    Xie, Kun
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, 19 (05) : 3005 - 3019
  • [34] Grid-Voltage-Feedback Active Damping With Lead Compensation for LCL-Type Inverter Connected to Weak Grid
    Zeng, Chengbi
    Wang, Hanwen
    Li, Sudan
    Miao, Hong
    IEEE ACCESS, 2021, 9 (09): : 106813 - 106823
  • [35] Impacts of Discretization of the Capacitor- Current Feedback Path Phase Lead Compensator on Digitally Controlled LCL-Type Grid-Connected Inverter Stability and Robustness
    Ren, Yuanzhe
    Lin, Hua
    Li, Shaojie
    Wang, Xingwei
    2022 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2022, : 1787 - 1792
  • [36] Capacitor Voltage Full Feedback Scheme for LCL-Type Grid-Connected Inverter to Suppress Current Distortion Due to Grid Voltage Harmonics
    Zhang, Hao
    Ruan, Xinbo
    Lin, Zhiheng
    Wu, Liguo
    Ding, Yong
    Guo, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (03) : 2996 - 3006
  • [37] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137
  • [38] Direct Realization of Digital Differentiators in Discrete Domain for Active Damping of LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (10) : 8461 - 8473
  • [39] Unified Active Damping Strategy Based on Generalized Virtual Impedance in LCL-Type Grid-Connected Inverter
    Chen, Wei
    Zhang, Yan
    Tu, Yiming
    Guan, Yuanpeng
    Shen, Ke
    Liu, Jinjun
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (08) : 8129 - 8139
  • [40] Dual Current Feedback Active Damping for Improving Transient Performance of LCL-filter-based Grid-connected Inverter
    Dong, Minghan
    Bai, Zhihong
    Ma, Hao
    2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 828 - 833