Reproducibility of intraocular lens decentration and tilt measurement using a clinical Purkinje meter

被引:65
|
作者
Nishi, Yutaro [1 ,2 ]
Hirnschall, Nino [1 ]
Crnej, Alja [1 ]
Gangwani, Vinod [1 ]
Tabernero, Juan [3 ]
Artal, Pablo [3 ]
Findl, Oliver [1 ]
机构
[1] Moorfields Eye Hosp NHS Fdn Trust, London EC1V 2PD, England
[2] UCL, Inst Ophthalmol, Dept Pathol, London, England
[3] Univ Murcia, Dept Fis, Lab Opt, E-30071 Murcia, Spain
来源
关键词
ANTERIOR-CHAMBER DEPTH; SPHERICAL-ABERRATION; PHAKIC EYES; POSITION; DESIGN; OPTICS; VALIDATION; SILICONE; SURFACES; SURGERY;
D O I
10.1016/j.jcrs.2010.03.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the reproducibility of intraocular lens (IOL) decentration and tilt measurements with a new Purkinje meter instrument. SETTING: Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. METHODS: After pupil dilation, images of pseudophakic eyes with a plate-style IOL (Akreos Adapt) were obtained using a recently developed Purkinje meter Intraocular lens decentration and tilt were evaluated by analyzing the captured images using a semiobjective method by marking the reflexes in the images and automatic calculation using a dedicated software program. In study 1, examiner 1 examined the eyes first followed by examiner 2 Ten minutes later, examiner 1 performed a second measurement, after which the intraexaminer and interexaminer reproducibility were determined In study 2, a Purkinje meter was used to measure pseudophakic eyes with slitlamp finding of clinical IOL decentration, IOL tilt, or both The results were compared with retroillumination photographs and slitlamp findings RESULTS: In study 1, there was high intraexaminer reproducibility for decentration (r = 0 95) and tilt (r = 0 85) and high interexaminer reproducibility for decentration (r = 0.84) and tilt (r = 0 75) In study 2, even in extreme cases of decentration and/or tilt, the Purkinje meter measurements were possible and appeared to correlate well with slitlamp findings. CONCLUSIONS: Acquisition of images in pseudophakic eyes with the Purkinje meter was simple and rapid. The method was highly reliable for 1 examiner and between 2 examiners. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2010; 36.1529-1535 (C) 2010 ASCRS and ESCRS
引用
收藏
页码:1529 / 1535
页数:7
相关论文
共 50 条
  • [1] Comparison of toric intraocular lens tilt and decentration measurement using dynamic Purkinje-meter and anterior segment optical coherence tomography
    Palkovicova, Eliska
    Cendelin, Jiri
    Novak, Jiri
    [J]. BIOMEDICAL PAPERS-OLOMOUC, 2024,
  • [2] MEASUREMENT OF INTRAOCULAR-LENS DECENTRATION AND TILT INVIVO
    PHILLIPS, P
    PEREZEMMANUELLI, J
    ROSSKOTHEN, HD
    KOESTER, CJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (02): : 129 - 135
  • [3] Comparison of intraocular lens decantation and tilt measurements using 2 Purkinje meter systems
    Maedel, Sophie
    Hirnschall, Nino
    Bayer, Natascha
    Markovic, Sabine
    Tabernero, Juan
    Artal, Pablo
    Schaeffel, Frank
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (05): : 648 - 655
  • [4] INVIVO MEASUREMENT OF POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION AND TILT
    AURAN, JD
    KOESTER, CJ
    DONN, A
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (01) : 75 - 79
  • [5] A purkinje imaging system for in vivo measurement of curvatures, tilt and decentration of the crystalline lens
    Rosales, P
    Barbero, S
    Marcos, S
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U706 - U706
  • [6] Dynamic Purkinje Meter as a Tool for Intraocular Lens Position Measurement
    Palkovicova, Eliska
    Cendelin, Jiri
    Kudrna, Petr
    [J]. INVENTIONS, 2024, 9 (03)
  • [7] Determination of Intraocular Lens Tilt and Decentration Using Simple and Rapid Method
    Mingxing Wu
    [J]. 眼科学报, 1998, (01) : 13 - 16
  • [8] Decentration and Tilt of Intraocular Lens after Posterior Capsulotomy
    Uzel, Mehmet Murat
    Ozates, Serdar
    Koc, Mustafa
    Uzel, Ayse Guzin Taslipinar
    Yilmazbas, Pelin
    [J]. SEMINARS IN OPHTHALMOLOGY, 2018, 33 (06) : 766 - 771
  • [9] Influence of intraocular lens tilt and decentration on wavefront aberrations
    Taketani, F
    Matuura, T
    Yukawa, E
    Hara, Y
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10): : 2158 - 2162
  • [10] MEASUREMENT OF INTRAOCULAR-LENS DECENTRATION
    KULNIG, W
    STANGLERZUSCHROTT, E
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1985, 187 (05) : 432 - 433