Decentration and Tilt of Intraocular Lens after Posterior Capsulotomy

被引:26
|
作者
Uzel, Mehmet Murat [1 ]
Ozates, Serdar [2 ]
Koc, Mustafa [2 ]
Uzel, Ayse Guzin Taslipinar [3 ]
Yilmazbas, Pelin [2 ]
机构
[1] Elmadag State Hosp, Ophthalmol Dept, Ankara, Turkey
[2] Ulucanlar Eye Res & Training Hosp, Ophthalmol Dept, Ankara, Turkey
[3] Yildirim Beyazit Univ, Ataturk Res & Training Hosp, Ophthalmol Dept, Ankara, Turkey
关键词
Intraocular lens decentration; intraocular lens tilt; hydrophobic intraocular lens; Nd:YAG laser capsulotomy; posterior capsule opacification; ANTERIOR-CHAMBER DEPTH; CATARACT-SURGERY; YAG CAPSULOTOMY; POSITION; EYES; OPACIFICATION; REFRACTION; NEODYMIUM; PRESSURE; PURKINJE;
D O I
10.1080/08820538.2018.1443146
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the effect of posterior capsular opacification (PCO) and Neodymium-doped:Yttrium Aluminium Garnet (Nd:YAG) laser capsulotomy on tilt and decentration of intraocular lens (IOL) at vertical and horizontal meridians. Methods: The study included 64 eyes of 64 patients. IOL decentration and tilt were measured using a Scheimpflug camera before and 1 month after Nd:YAG capsulotomy. Corrected distance visual acuity (CDVA) and manifest refraction were also determined. Between-group differences of IOL position change and the effect of Nd:YAG laser capsulotomy were analyzed. Results: In the PCO group, before capsulotomy, CDVA was significantly lower than that after capsulotomy and of the control group values (p = 0.001 for both). No significant difference was observed in CDVA between the control group and the PCO group after capsulotomy (p = 0.854). Before capsulotomy, the angle of tilt and decentration at both meridians was significantly higher than that in the control group (tilt: p < 0.001; for both decentrations: p = 0.001, p = 0.003, respectively). A significant decrease was observed in the angle of tilt at both meridians (horizontal p = 0.001, vertical p = 0.001) from before to after capsulotomy in the PCO group. Although decentration was increased after capsulotomy, no significant position change was observed (horizontal p = 0.350, vertical p = 0.107). The angle of tilt and decentration at both meridians was significantly higher in the PCO group after capsulotomy compared to the control group (p < 0.001 for all). Conclusions: PCO is associated with not only axial displacement, but also tilt and decentration of IOL at the vertical and horizontal meridians. Laser capsulotomy decreased IOL tilt but had no effect on decentration. However, these changes did not significantly change the visual acuity between the control group and the PCO group after capsulotomy.
引用
收藏
页码:766 / 771
页数:6
相关论文
共 50 条
  • [1] Intraocular lens tilt and decentration after Nd:YAG laser posterior capsulotomy: Femtosecond laser capsulorhexis versus manual capsulorhexis
    Cinar, Esat
    Yuce, Berna
    Aslan, Fatih
    Erbakan, Gokhan
    Kucukerdonmez, Cem
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11): : 1637 - 1644
  • [2] TILT AND DECENTRATION OF THE IMPLANTED POSTERIOR CHAMBER INTRAOCULAR-LENS
    KOZAKI, J
    TANIHARA, H
    YASUDA, A
    NAGATA, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (05): : 592 - 595
  • [3] The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses
    Mutlu, FM
    Bilge, AH
    Altinsoy, HI
    Yumusak, E
    [J]. OPHTHALMOLOGICA, 1998, 212 (06) : 359 - 363
  • [4] INVIVO MEASUREMENT OF POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION AND TILT
    AURAN, JD
    KOESTER, CJ
    DONN, A
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (01) : 75 - 79
  • [5] Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation
    Durak, I
    Öner, HF
    Koçak, N
    Kaynak, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02): : 227 - 232
  • [6] Determinants of intraocular lens tilt and decentration after cataract surgery
    Gu, Xiaoxun
    Chen, Xiaoyun
    Yang, Guangyao
    Wang, Wei
    Xiao, Wei
    Jin, Guangming
    Wang, Lanhua
    Dai, Ye
    Ruan, Xiaoting
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)
  • [7] Intraocular lens tilt and decentration after implantation in eyes with glaucoma
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (11): : 1515 - 1520
  • [8] Intraocular lens tilt and decentration after cataract surgery with and without primary posterior continuous curvilinear capsulorhexis
    Liu, Xiaobao
    Yu, Mengting
    Huang, Yue
    Li, Qiong
    Wu, Wenjie
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (05): : 492 - 498
  • [9] Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (11) : 1294 - 1297
  • [10] CONTINUOUS TEAR CAPSULOTOMY AND INTRAOCULAR-LENS DECENTRATION - REPLY
    COLVARD, DM