摘要
Management of surgically induced astigmatism is an important problem for surgeons implanting intraocular lenses. Besides corneal astigmatism, the fixation status of the intraocular lens (IOL) may contribute to total astigmatism. This study was undertaken to evaluate the effect of tilt and decentration of the implanted posterior chamber IOL on the total astigmatism. The tilting angle of the IOL was measured by a method using the 3rd and 4th Purkinje images, and the grade of the decentration was obtained photogrammetrically. The average tilt angle was 7.53 +/- 3.03 degrees (SD). The average decentration was 0.68 +/- 0.33 mm (SD) from the corneal center. Based on these data, the astigmatic error induced by the tilt or decentration of the implanted IOL was calculated as within 0.4 diopter. These data suggest that the fixation status of the IOL implanted in the bag does not cause a serious astigmatic error.
引用
收藏
页码:592 / 595
页数:4
相关论文
共 50 条
  • [1] INVIVO MEASUREMENT OF POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION AND TILT
    AURAN, JD
    KOESTER, CJ
    DONN, A
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (01) : 75 - 79
  • [2] MEASUREMENT OF INTRAOCULAR-LENS DECENTRATION AND TILT INVIVO
    PHILLIPS, P
    PEREZEMMANUELLI, J
    ROSSKOTHEN, HD
    KOESTER, CJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (02): : 129 - 135
  • [3] POSTERIOR CAPSULAR OPACIFICATION AND INTRAOCULAR-LENS DECENTRATION .1. COMPARISON OF VARIOUS POSTERIOR CHAMBER LENS DESIGNS IMPLANTED IN THE RABBIT MODEL
    HANSEN, SO
    SOLOMON, KD
    MCKNIGHT, GT
    WILBRANDT, TH
    GWIN, TD
    OMORCHOE, DJC
    TETZ, MR
    APPLE, DJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (06): : 605 - 613
  • [4] REDUCING TILT AND DECENTRATION OF SUTURED INTRAOCULAR-LENS IMPLANTS
    SOSSI, NP
    FRUEH, BE
    FELDMAN, ST
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 796 - 796
  • [5] PROSPECTIVE EXPERIMENTAL-STUDY OF FACTORS RELATED TO POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION
    LEGLER, UFC
    ASSIA, EI
    CASTANEDA, VE
    HOGGATT, JP
    APPLE, DJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05): : 449 - 455
  • [6] DECENTRATION OF AN ALL-PMMA POSTERIOR CHAMBER INTRAOCULAR-LENS DUE TO HAPTIC DEFORMATION
    SULEWSKI, ME
    STARK, WJ
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (03) : 316 - 317
  • [7] INSERTION OF POSTERIOR CHAMBER INTRAOCULAR-LENS
    HARBIN, RL
    MATTINGLY, TP
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (04) : 560 - 561
  • [8] Decentration and Tilt of Intraocular Lens after Posterior Capsulotomy
    Uzel, Mehmet Murat
    Ozates, Serdar
    Koc, Mustafa
    Uzel, Ayse Guzin Taslipinar
    Yilmazbas, Pelin
    [J]. SEMINARS IN OPHTHALMOLOGY, 2018, 33 (06) : 766 - 771
  • [9] MEASUREMENT OF INTRAOCULAR-LENS DECENTRATION
    KULNIG, W
    STANGLERZUSCHROTT, E
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1985, 187 (05) : 432 - 433
  • [10] Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation
    Durak, I
    Öner, HF
    Koçak, N
    Kaynak, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02): : 227 - 232