Development of an electrochemical immunosensor to determine zearalenone in maize using carbon screen printed electrodes modified with multi-walled carbon nanotubes/polyethyleneimine dispersions

被引:71
|
作者
Ivan Riberi, Walter [1 ]
Viviana Tarditto, Lorena [1 ]
Alicia Zon, Maria [1 ]
Javier Arevalo, Fernando [1 ]
Fernandez, Hector [1 ]
机构
[1] Univ Nacl Rio Cuarto, Fac Ciencias Exactas Fis Quim & Nat, Dept Quim, Grp Electroanalit GEANA, Agencia Postal 3, RA-5800 Rio Cuarto, Argentina
来源
关键词
Zearale none; Electrochemical immunosensor; Amperometry; Multi-walled carbon; nanotubes/polyethyleneimine dispersions; Maize samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; IMMUNOAFFINITY COLUMN CLEANUP; ALPHA-ZEARALENOL; LC-MS/MS; VALIDATION; CORN; DEOXYNIVALENOL; IMMUNOASSAY; METABOLITES; OCHRATOXIN;
D O I
10.1016/j.snb.2017.07.113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical immunosensor is developed to determine zearalenone (ZEA) mycotoxin in maize samples. It is based on the use of a composite, which was prepared from anti-ZEA poly-clonal antibody bonded to gold nanoparticles immobilized on multi-walled carbon nanotubes/polyethyleneimine dispersions. Carbon screen printed-electrodes (CSPE) were used in the electrochemical transduction stage. The immunoassay is based on a direct competitive assay between ZEA in maize samples and ZEA labeled with horseradish peroxidase enzyme (ZEA-HRP). ZEA determination was performed by amperometry, using an applied potential of -0.3 V. The H2O2, which was not consumed by HRP, was reduced at the electrochemical immunosensor surface. Thus, the reduction current was proportional to the amount of ZEA present in samples. All experimental variables involved in the construction of the electrochemical immunosensor were optimized. The linear concentration range is from 1 x 10(-4) to 1 x 10(-1) ng mL(-1). The limit of detection and SC50 were 0.15 pg mL(-1) and 2 pg mL(-1), respectively. In addition, an acceptable accuracy, with a percentual coefficient of variation (%CV) less than 20%, and recovery percentages close to 105% were found. The electrochemical immunosensor has great advantages such as no pre-treatment of the sample is required, the sample volume is of 20 mu L, the experiments require short times and a very low limit of detection is obtained. Results obtained with this electrochemical immunosensor were compared with those determined by HPLC-fluorescence detection, obtaining a very good correlation. The proposed immunosensor is a valuable alternative tool to determine ZEA in maize samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1271 / 1277
页数:7
相关论文
共 50 条
  • [21] Ionic liquid-multi-walled carbon nanotubes modified screen-printed electrodes for sensitive electrochemical sensing of uranium
    Tamer A. Ali
    Zeinab F. Akl
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 328 : 267 - 276
  • [22] Ionic liquid-multi-walled carbon nanotubes modified screen-printed electrodes for sensitive electrochemical sensing of uranium
    Ali, Tamer A.
    Akl, Zeinab F.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 328 (01) : 267 - 276
  • [23] Smartphone-based electrochemical system with multi-walled carbon nanotubes/thionine/gold nanoparticles modified screen-printed immunosensor for cancer antigen 125 detection
    Fan, Yan
    Shi, Shengyu
    Ma, Junshuang
    Guo, Yaohua
    MICROCHEMICAL JOURNAL, 2022, 174
  • [24] A high-performance, disposable screen-printed carbon electrode modified with multi-walled carbon nanotubes/graphene for ultratrace level electrochemical sensors
    Patiya Pasakon
    Johannes Philipp Mensing
    Ditsayut Phokaratkul
    Chanpen Karuwan
    Tanom Lomas
    Anurat Wisitsoraat
    Adisorn Tuantranont
    Journal of Applied Electrochemistry, 2019, 49 : 217 - 227
  • [25] A high-performance, disposable screen-printed carbon electrode modified with multi-walled carbon nanotubes/graphene for ultratrace level electrochemical sensors
    Pasakon, Patiya
    Mensing, Johannes Philipp
    Phokaratkul, Ditsayut
    Karuwan, Chanpen
    Lomas, Tanom
    Wisitsoraat, Anurat
    Tuantranont, Adisorn
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2019, 49 (02) : 217 - 227
  • [26] Electrochemical parameters of ethamsylate at multi-walled carbon nanotube modified glassy carbon electrodes
    Wang, Sheng-Fu
    Xu, Qiao
    BIOELECTROCHEMISTRY, 2007, 70 (02) : 296 - 300
  • [27] Simultaneous electrochemical determination of hydroquinone, catechol and resorcinol at Nafion/multi-walled carbon nanotubes/carbon dots/multi-walled carbon nanotubes modified glassy carbon electrode
    Wei, Chan
    Huang, Qitong
    Hu, Shirong
    Zhang, Hanqiang
    Zhang, Wuxiang
    Wang, Zhaoming
    Zhu, Menglin
    Dai, Pingwang
    Huang, Lizhang
    ELECTROCHIMICA ACTA, 2014, 149 : 237 - 244
  • [28] Structural and electrochemical characterization of carbon electrode modified by multi-walled carbon nanotubes and surfactant
    Pajootan, Elmira
    Arami, Mokhtar
    ELECTROCHIMICA ACTA, 2013, 112 : 505 - 514
  • [29] Electrochemical Determination of Resveratrol Using Multi-Walled Carbon Nanotubes-Modified Glassy Carbon Electrode
    Huang, Wensheng
    Luo, Shijia
    Zhou, Dazhai
    Zhang, Shenghui
    Wu, Kangbing
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2013, 5 (03) : 367 - 371
  • [30] An Electrochemical Immunosensor for C-Reactive Protein Based on Multi-Walled Carbon Nanotube-Modified Electrodes
    Buch, Michal
    Rishpon, Judith
    ELECTROANALYSIS, 2008, 20 (23) : 2592 - 2594