Simultaneous electrochemical determination of hydroquinone, catechol and resorcinol at Nafion/multi-walled carbon nanotubes/carbon dots/multi-walled carbon nanotubes modified glassy carbon electrode

被引:109
|
作者
Wei, Chan [1 ]
Huang, Qitong [2 ]
Hu, Shirong [1 ]
Zhang, Hanqiang [1 ]
Zhang, Wuxiang [1 ]
Wang, Zhaoming [1 ]
Zhu, Menglin [1 ]
Dai, Pingwang [3 ]
Huang, Lizhang [3 ]
机构
[1] Minnan Normal Univ, Coll Chem & Environm, Zhangzhou 363000, Peoples R China
[2] Zhangzhou Inst Technol, Dept Food & Biol Engn, Zhangzhou 363000, Peoples R China
[3] Zhangzhou Prod Qual Supervis Inst, Zhangzhou 363000, Peoples R China
关键词
simultaneous determination; dihydroxybenzene isomers; electrochemical sensor; carbon dots; multi-walled carbon nanotubes; DIHYDROXYBENZENE ISOMERS; HYBRID MATERIALS; IONIC LIQUID; DOTS; PHENOL; SENSOR; FILMS;
D O I
10.1016/j.electacta.2014.10.051
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, an excellent electrochemical sensor based on Nafion/multi-walled carbon nanotubes/carbon dots/multi-walled carbon nanotubes (Nafion/MWCNTs/CDs/MWCNTs) for simultaneous determination of hydroquinone (HQ), catechol (CC) and resorcinol (RS) in 0.1 M phosphate buffer solutions (PBS, pH = 7.0) was found. The functioned MWCNTs, which contained amido bond, were combined to CDs via the electrostatic interaction to build the Nafion/MWCNTs/CDs/MWCNTs modified electrode. As we know, MWCNTs have large specific surface area and CDs have electrical conductivity, which were benefited to build the composite modified electrode. The three dihydroxybenzene isomers could well separate from each other at the scan rate of 100 mV s (1) with a potential difference of 119 mV and 419 mV for the oxidation peak potentials of HQ-CC and CC-RS, respectively. Differential pulse voltammetry (DPV) was used for the simultaneous determination of HQ, CC and RS in their ternary mixture. The peak current obtained was linearly dependent on the HQ, CC and RS concentrations in the range of 1.0 to 200.0 mu M, 4.0 to 200.0 mu M and 3.0 to 400.0 mu M and the detection limits for HQ, CC and RS were 0.07 mu M, 0.06 mu M and 0.15 mu M (S/N = 3), respectively. The modified electrode was applied to detect the tap water, well water and river water and the recoveries of tap water, well water and river water samples were 100.3-109.8% for HQ, 96.0-105.8% for CC and 83.4-101.6% for RS, respectively. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [1] Electrochemical Determination of Hydroquinone and Catechol Using Multi-walled Carbon Nanotubes/eosin Y Modified Glassy Carbon Electrode
    Zheng, Shengbiao
    Liu, Jing
    Liu, Renhao
    Hui, Zhenzhen
    Tang, Jing
    Wang, Xuchun
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6234 - 6246
  • [2] Electrochemical properties and the determination of nicotine at a multi-walled carbon nanotubes modified glassy carbon electrode
    Xiong, Huayu
    Zhao, Yunfei
    Liu, Peng
    Zhang, Xiuhua
    Wang, Shengfu
    [J]. MICROCHIMICA ACTA, 2010, 168 (1-2) : 31 - 36
  • [3] Electrochemical properties and the determination of nicotine at a multi-walled carbon nanotubes modified glassy carbon electrode
    Huayu Xiong
    Yunfei Zhao
    Peng Liu
    Xiuhua Zhang
    Shengfu Wang
    [J]. Microchimica Acta, 2010, 168 : 31 - 36
  • [4] Electrochemical determination of berberine at a multi-walled carbon nanotubes-modified glassy carbon electrode
    Geto, Alemnew
    Pita, Marcos
    De Lacey, Antonio L.
    Tessema, Merid
    Admassie, Shimelis
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 96 - 101
  • [5] Multi-walled carbon nanotubes modified glassy carbon electrode for sensitive determination of ketoconazole
    Borowiec, Joanna
    Wei, Lili
    Zhu, Lihua
    Zhang, Jingdong
    [J]. ANALYTICAL METHODS, 2012, 4 (02) : 444 - 448
  • [6] A Sensitive Simultaneous Determination of Acetaminophen and Indomethacin at Multi-walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Babaei, Ali
    Farshbaf, Mojtaba
    Afrasiabi, Mohammad
    Dehdashti, Aliyeh
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (06): : 564 - 578
  • [7] A Sensor for Simultaneous Determination of Acetaminophen and Codeine at Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes
    Babaei, Ali
    Dehdashti, Aliyeh
    Afrasiabi, Mohammad
    Babazadeh, Mitra
    Farshbaf, Mojtaba
    Bamdad, Farzad
    [J]. SENSOR LETTERS, 2012, 10 (3-4) : 1039 - 1046
  • [8] Electrochemical Determination of Vitamin C on Glassy Carbon Electrode Modified by Carboxyl Multi-walled Carbon Nanotubes
    He, Baoshan
    Zhang, Junxia
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (11): : 9621 - 9631
  • [9] Electrochemical Oxidation and Determination of Methocarbamol at Multi-walled Carbon Nanotubes-Modified Glassy Carbon Electrode
    Lamani, Shekappa D.
    Teradale, Amit B.
    Unki, Shrishail N.
    Nandibewoor, Sharanappa T.
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (03): : 304 - 317
  • [10] Electrochemical Determination of Resveratrol Using Multi-Walled Carbon Nanotubes-Modified Glassy Carbon Electrode
    Huang, Wensheng
    Luo, Shijia
    Zhou, Dazhai
    Zhang, Shenghui
    Wu, Kangbing
    [J]. NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2013, 5 (03) : 367 - 371