Locally tuned deformation fields combination for 2D cine-MRI-based driving of 3D motion models

被引:7
|
作者
Dasnoy-Sumell, D. [1 ]
Aspeel, A. [1 ]
Souris, K. [2 ]
Macq, B. [1 ]
机构
[1] Catholic Univ Louvain, Inst Informat & Commun Technol Elect & Appl Math, ImagX R Lab, Pl Levant 3 Box L5-03-02, B-1348 Louvain La Neuve, Belgium
[2] Catholic Univ Louvain, Inst Rech Expt & Clin, Mol Imaging Radiotherapy & Oncol, Ave Hippocrate 54 Box B1-54-07, B-1200 Brussels, Belgium
关键词
3D motion model; Cine-MRI; IGRT; Real-time tracking; Image processing; PARTICLE THERAPY; TRACKING; CT;
D O I
10.1016/j.ejmp.2021.12.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To target mobile tumors in radiotherapy with the recent MR-Linac hardware solutions, research is being conducted to drive a 3D motion model with 2D cine-MRI to reproduce the breathing motion in 4D. This work presents a method to combine several deformation fields using local measures to better drive 3D motion models. Methods: The method uses weight maps, each representing the proximity with a specific area of interest. The breathing state is evaluated on cine-MRI frames in these areas and a different deformation field is estimated for each using a 2D to 3D motion model. The different deformation fields are multiplied by their respective weight maps and combined to form the final field to apply to a reference image. A global motion model is adjusted locally on the selected areas and creates a 3DCT for each cine-MRI frame. Results: The 13 patients on which it was tested showed on average an improvement of the accuracy of our model of 0.71 mm for areas selected to drive the model and 0.5 mm for other areas compared to our previous method without local adjustment. The additional computation time for each region was around 40 ms on a modern laptop. Conclusion: The method improves the accuracy of the 2D-based driving of 3D motion models. It can be used on top of existing methods relying on deformation fields. It does add some computation time but, depending on the area to deform and the number of regions of interests, offers the potential of online use.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [21] Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation
    Romero, X. C.
    Molina, F. S.
    Pastor, E.
    Amaya, F.
    FETAL DIAGNOSIS AND THERAPY, 2011, 29 (03) : 257 - 260
  • [22] The topology of scalar fields in 2D and 3D turbulence
    Moffatt, HK
    IUTAM SYMPOSIUM ON GEOMETRY AND STATISTICS OF TURBULENCE, 2001, 59 : 13 - 22
  • [23] Polarization singularities in 2D and 3D speckle fields
    Flossmann, Florian
    O' Holleran, Kevin
    Dennis, Mark R.
    Padgett, Miles J.
    PHYSICAL REVIEW LETTERS, 2008, 100 (20)
  • [24] Comparative Analysis of Bulge Deformation between 2D and 3D Finite Element Models
    Qin, Qin
    Shang, Shu
    Wu, Diping
    Zang, Yong
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [25] Smooth motion of a rigid body in 2D and 3D
    Chaudhry, FS
    Handscomb, DC
    1997 IEEE CONFERENCE ON INFORMATION VISUALIZATION, PROCEEDINGS: AN INTERNATIONAL CONFERENCE ON COMPUTER VISUALIZATION & GRAPHICS, 1997, : 205 - 210
  • [26] RELATIVE EFFICIENCY OF 2D AND 3D MOTION JUDGMENTS
    CROWELL, JA
    BANKS, MS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1364 - 1364
  • [27] 2D and 3D shape based segmentation using deformable models
    El-Baz, A
    Yuksel, SE
    Shi, HJ
    Farag, AA
    El-Ghar, MA
    Eldiasty, T
    Ghoneim, MA
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 821 - 829
  • [28] Novel method of 2D motion images into 3D motion images
    Hou, Chunping
    Yu, Sile
    Moshi Shibie yu Rengong Zhineng/Pattern Recognition and Artificial Intelligence, 2003, 16 (04):
  • [29] Significance of intrafractional motion in pelvic organs: a multiplanar 3D Cine MRI study
    Sripadam, R
    Sharrock, P
    Moore, C
    Price, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S501 - S502
  • [30] Quantifying right ventricular motion and strain using 3D cine DENSE MRI
    Auger D.A.
    Zhong X.
    Meintjes E.M.
    Epstein F.H.
    Spottiswoode B.S.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)