NON-INVASIVE DETECTION OF DIFFUSE INTRACRANIAL VERTEBROBASILAR ARTERY STENOSIS: A PROSPECTIVE COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY

被引:2
|
作者
Zhang, Jie [1 ]
Wang, Lijuan [1 ]
Chen, Ying [1 ]
Wang, Sibo [1 ]
Cui, Li [1 ]
机构
[1] Jilin Univ, Hosp 1, Dept Neurol, Neurosci Ctr, Changchun, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2022年 / 48卷 / 03期
关键词
Intracranial atherosclerosis; Vertebrobasilar artery stenosis; Diffuse stenosis; transcranial Doppler; Duplex ultrasonography; MIDDLE CEREBRAL-ARTERY; TRANSIENT ISCHEMIC ATTACK; COLOR-CODED SONOGRAPHY; TRANSCRANIAL DOPPLER; VERTEBRAL ARTERY; FOLLOW-UP; STROKE; MULTICENTER; PREVALENCE; RISK;
D O I
10.1016/j.ultrasmedbio.2021.11.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to prospectively evaluate diffuse intracranial vertebrobasilar artery stenosis by ultrasonic examination with digital subtraction angiography as the reference. Five hundred forty-one vertebrobasilar arteries with a normal lumen or intracranial stenosis were enrolled. Peak systolic velocity, mean flow velocity and end-diastolic velocity (EDV) at the intracranial vertebrobasilar arteries and extracranial vertebral arteries (VAs) were measured. The resistance index (RI) at extracranial VAs and the difference between the RI of extracranial VAs and the RI of the extracranial internal carotid artery (Mica) were calculated. Compared with normal arteries, all stenotic arteries were divided into the high-velocity group (focal stenosis, multiple-segment stenosis and multiple-artery stenosis) and low-velocity group (critical stenosis and long stenosis). The consistency between ultrasonic examination and digital subtraction angiography for evaluation of vertebrobasilar arteries with multiple-segment stenosis and multiple-artery stenosis was not favorable when applying the widely used Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis criteria (kappa = 0.442 and 0.438, respectively). The optimal low-velocity criteria for identifying intracranial vertebrobasilar arteries with critical stenosis and long stenosis were determined by receiver operating characteristic curve analysis and were as follows: EDV <15 cm/s and RI >0.68 at the extracranial VA and Rlica >= 0.10. (C) 2021 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:554 / 564
页数:11
相关论文
共 50 条
  • [31] Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis
    Thornton, J
    O'Callaghan, J
    Walshe, J
    O'Brien, E
    Varghese, JC
    Lee, MJ
    EUROPEAN RADIOLOGY, 1999, 9 (05) : 930 - 934
  • [32] Validation of computed tomography angiography as a complementary test in the assessment of renal artery stenosis: a comparison with digital subtraction angiography
    Fleury, Anilawan S.
    Durand, Rachelle E.
    Cahill, Anne Marie
    Zhu, Xiaowei
    Meyers, Kevin E.
    Otero, Hansel J.
    PEDIATRIC RADIOLOGY, 2021, 51 (13) : 2507 - 2520
  • [33] Validation of computed tomography angiography as a complementary test in the assessment of renal artery stenosis: a comparison with digital subtraction angiography
    Anilawan S. Fleury
    Rachelle E. Durand
    Anne Marie Cahill
    Xiaowei Zhu
    Kevin E. Meyers
    Hansel J. Otero
    Pediatric Radiology, 2021, 51 : 2507 - 2520
  • [34] Color Doppler ultrasonography of the vertebral artery: Prospective study in comparison with digital subtraction angiography
    Kim, JM
    Kim, S
    Huh, J
    Cho, Y
    RADIOLOGY, 2001, 221 : 592 - 592
  • [35] Duplex Ultrasonography for the Evaluation of Extracranial Vertebral Artery: A Prospective Comparison With Digital Subtraction Angiography
    Zhang, Jie
    Xing, Yingqi
    Cui, Li
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [36] Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis
    J. Thornton
    J. O'Callaghan
    J. Walshe
    E. O'Brien
    J. C. Varghese
    M. J. Lee
    European Radiology, 1999, 9 : 930 - 934
  • [37] VENOUS DIGITAL SUBTRACTION ANGIOGRAPHY FOR DIAGNOSIS OF RENAL-ARTERY STENOSIS IN ARTERIAL HYPERTONY - COMPARISON WITH CONVENTIONAL ANGIOGRAPHY
    SCHORNER, W
    KEMPTER, H
    BANZER, D
    AVILES, C
    WEISS, T
    FELIX, R
    RADIOLOGE, 1984, 24 (04): : 171 - 176
  • [38] Carotid artery stenosis measurement: Comparison of cone-beam CT and digital subtraction angiography
    Hyde, D
    Fox, A
    Gulka, I
    Kalapos, P
    Lee, D
    Pelz, D
    MEDICAL PHYSICS, 2003, 30 (07) : 1950 - 1950
  • [39] CASMatching strategy for automated detection and quantification of carotid artery stenosis based on digital subtraction angiography
    Wulamu, Aziguli
    Luo, Jichang
    Chen, Saian
    Zheng, Han
    Wang, Tao
    Yang, Renjie
    Jiao, Liqun
    Zhang, Taohong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 243
  • [40] NON-INVASIVE DIAGNOSIS OF INTRACRANIAL LESIONS IN THE VERTEBROBASILAR SYSTEM - A COMPARISON OF DOPPLER SONOGRAPHIC AND ANGIOGRAPHIC FINDINGS
    RINGELSTEIN, EB
    ZEUMER, H
    POECK, K